CO2 Data logger
Air quality data logger for 5 parameters / Measures temperature, humidity, CO2, PM2.5 and air pressure /
SD storage / XLS format / Large LCD / Power adapter and battery operation
One of the best ways to provide an appropriate control of the indoor air is an application of the Room Climate Data Logger. An expert on safety and health in the workplace can easily give a profound and detailed description of the indoor climate, since with the help of the room air data logger application, one gets all the required data (air quality parameters, like temperature, humidity, CO2, dust particles, air pressure) at his disposal and can carry out a professional analysis. The obtained data are not lost due to the SD-memory-card-storage option in XLS format. The latter feature is a facilitation or the user, and there is no need to use any additional software for reading the data. Excel is absolutely enough for that.
The design of the Room Climate Data Logger is such that a look at the large screen may be sufficient for getting and overview of not only all the measured parameters, but also current time. The user has an option of how to operate the device, either power supply (9 V) or batteries. An advantageous feature is that the user gets an auxiliary notification when the situation with the room climate gets worse and some measures are required. If the values go beyond the permissible range, the alarm sounds. Thus, the operator not only is able to fully characterize the current indoor climate, but also to react immediately.

If the Room Climate Data Logger for indoor climate monitoring indicates that the parameters have gone much higher than desirable, short-term airing may be not enough. In such cases, application of additional air conditioning and cleaning devices is desirable. Besides, dust must be eliminated out of the room: both measures, intense dedusting and wet cleaning must be taken. Such measures lead to certain costs-increase, but they will provide continuous help in the improvement of the room climate.

The devices ordered from PCE Instruments are not only delivered to the customer, but they are also factory-calibrated (1-2 days delivery time). In case, the compliance with ISO norms (e.g. DIN ISO 9000) is required, PCE Instruments provides an option of purchasing the ISO calibration certificate (delivery time with the certificate 4-7 days). A few steps, like creation of the test protocol, including the data about your firm, and including the indoor climate data loggers into your in-house ISO test equipment pool, enable to make conclusion about compliance of the devices with the Norms. The whole procedure takes some time (from 3 to 5 days) and must be carried out only if the ISO certification is needed. Besides that, to provide correct and accurate operation of the device, recalibration is desirable.
The frequency of recalibrating procedures is usually specified, but it may also be done any time on demand. The user has got a chance, whether to carry it out for all the measurands (5 in the air quality data logger) or just for the most significant ones, which are likely to change tremendously, like relative humidity or dust load. The latter is called partial calibrations and may be carried out with the purpose of saving some costs. You are welcome to have a look at the presented certificates: tab "Accessories / Options".
| Measurement function PM2.5 | |
| Measuring range | 0 ... 250 μm / m³ |
| Resolution | 1 μm / m³ |
| Accuracy | ± (10% of rdg. + 15 μm) |
| Measuring function humidity | |
| Measuring range | 5 ... 95% rh |
| Resolution | 0.1% RH |
| Accuracy | > 70% RH: ± (3% of the prev |
| + 1% RH) | |
| <70% RH: ± 3% RH | |
| Measuring function temperature | |
| Measuring range | 0 ... 50°C / 32 ... 122°F |
| Resolution | 0.1°C / 0.18°F |
| Accuracy | ± 0.8°C / 1.44°F |
| Measurement function CO2 | |
| Measuring range | 0 ... 10,000 ppm |
| Resolution | 1 ppm |
| Accuracy | < 1000 ppm: ± 40 ppm |
| < 3000 ppm: ± (50 ppm + 3% of rdg.) | |
| > 3000 ppm: ± (50 ppm + 5% of rdg.) | |
| Measuring function air pressure | |
| Measuring range | 10 ... 1100 hPa |
| Resolution | 0.1 hPa |
| Accuracy | ± 1.5 hPa |
| Display | LCD display with backlight |
| Storage | SD card max. 32 GB |
| Storage rate | 2 ... 3,600 s |
| Memory error | < 0.1% of the completely stored data |
| Display | Hold, Max, Min |
| Measuring rate | About 1 s |
| Interface | Serial for live visualization on computers |
| (Data cable SOFT-LUT-USB sold separately) | |
| Alarm output | OC output 24V / 70-mA DC |
| Power supply | 6 x 1.5V AA battery |
| 9V / 1 A power adapter | |
| Current consumption | 230-mA without lighting |
| approx. 250-mA with lighting | |
| Operating conditions | 0 ... 50°C / 32 ... 122°F, max. 80% rh |
| Weight | About 387 g / < 1 lb |
| Dimensions | 164 x 93 x 72 mm / 6.5 x 3.7 x 2.8 in |