Data Logger / Data Logging Instrument PCE-PA 6500 F50
£ 890.00
Price excl. VAT &. delivery
The Data Logger / Data Logging Instrument measures current and voltage values using the connected current transformers and test leads. From this, the active, apparent and reactive power are determined and transmitted to the measuring platform every second via Wi-Fi. The data is then filed historically on the Data Logger / Data Logging Instrument, processed graphically and can be analysed or exported.

  • alternating voltage: 40 ... 400 V
  • alternating current: 2 ... 1250 A
  • resolution: 0.01 V / 0.01 A
  • active, apparent and reactive power
  • electrical energy in Wh
  • incl. app for Android
  • 32 GB internal memory
  • magnetic measuring adaptor
Data Logger / Data Logging Instrument PCE-PA 6500 F150
£ 890.00
Price excl. VAT &. delivery
The Data Logger / Data Logging Instrument measures current and voltage values using the connected current transformers and test leads. From this, the active, apparent and reactive power are determined and transmitted to the measuring platform every second via Wi-Fi. The data is then filed historically on the Data Logger / Data Logging Instrument, processed graphically and can be analysed or exported.

  • alternating voltage: 40 ... 400 V
  • alternating current: 3 ... 4800 A
  • resolution: 0.01 V / 0.01 A
  • active, apparent and reactive power
  • electrical energy in Wh
  • incl. app for Android
  • 32 GB internal memory
  • magnetic measuring adaptor
Data Logger PCE-PCO 1
£ 843.00
Price excl. VAT &. delivery
Topseller

PCE-PCO 1 is a handheld data logger for measuring the concentration of particles in the air. The PCE-PCO 1 data logger:


  • Measures 6 sizes of particles: 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm
  • Offers a robust, 80 MB internal memory
  • Features a large, full-color LCD display with backlight
  • Includes a built-in camera for image and video recording
  • Contains sensors for measuring air temperature, dew point and relative  humidity
  • Displays temperature in degrees Celsius (°C) or Fahrenheit (°F)

Vibration Data Logger PCE-VDR 10-ICA incl. ISO Calibration Certificate
£ 855.00
Price excl. VAT &. delivery
ISO Calibration

PCE-VDR 10-ICA is a single-axis accelerometer or vibration data logger monitor with real-time measurement and data logging capabilities. This vibration data logger records acceleration (m/s, g, ft/s) as well as velocity (mm/s, cm/s, in/s) measurements and saves the measured data to an included SD card memory. There is also an analog output, which makes this vibration data logger compatlble with control systems.

  • Acceleration measuring range:   0.5 … 199.9 m/s, 0.05 … 20.39 g, 2 … 656 ft/s
  • Velocity measuring ranges:   0.5 … 199.9 mm/s, 0.05 … 19.99 cm/s, 0.02 … 7.87 in/s
  • Frequency range: 10 … 1000 Hz
  • Analog output: 4 … 20 mA
  • RS-232 and USB interface
  • incl. ISO Calibration Certificate

Shock Data Logger PCE-VDR 10-ICA incl. ISO Calibration Certificate
£ 855.00
Price excl. VAT &. delivery
ISO Calibration

PCE-VDR 10-ICA is a single-axis accelerometer or shock data logger with real-time measurement and data logging capabilities. This shock data logger records acceleration (m/s, g, ft/s) as well as velocity (mm/s, cm/s, in/s) measurements and saves the measured data to an included SD card memory. There is also an analog output, which makes this shock data logger compatlble with control systems.

  • Acceleration measuring range:   0.5 … 199.9 m/s, 0.05 … 20.39 g, 2 … 656 ft/s
  • Velocity measuring ranges:   0.5 … 199.9 mm/s, 0.05 … 19.99 cm/s, 0.02 … 7.87 in/s
  • Frequency range: 10 … 1000 Hz
  • Analog output: 4 … 20 mA
  • RS-232 and USB interface
  • incl. ISO Calibration Certificate

dB Data Logger PCE-NDL 10-ICA incl. ISO Calibration Certificate
£ 795.00
Price excl. VAT &. delivery
ISO Calibration

The dB data logger is used to determine volume. The PCE-NDL 10 dB data logger is a handy measuring device that meets the highest requirements. In order to evaluate the measured data in the best possible way, it is possible to use the internal measurement data memory on the noise dosimeter. In addition, the dB data logger has an SD card slot that enables the use of an SD card as an additional storage medium.


  • Measuring range: SPL: Auto 30 … 130 dB
  • Resolution: 0.1 dB
  • Low sampling rate
  • Automatic or manual storage
  • Selectable storage interval
  • Backlit LC display
  • Dose measurement or SPL measurement

Temperature Data Logger PCE-AQD 20-ICA Incl. ISO Calibration Certificate
£ 765.00
Price excl. VAT &. delivery
ISO Calibration
The temperature data logger PCE-AQD 20 is an ideal measuring device for monitoring the air quality at workplaces. The health and environmental temperature data logger is ideal for continuous logging of air temperature, humidity, CO2, PM2.5 and air pressure.

Measuring function
  • PM2.5
  • Humidity
  • Temperature
  • CO2
  • Air pressure
  • Memory: SD card max. 32 GB
  • Ideal for workplace monitoring
  • Alarm function
  • Incl. ISO calibration certificate
CO2 / Room Climate Data Logger PCE-AQD 20-ICA Incl. ISO Calibration Certificate
£ 765.00
Price excl. VAT &. delivery
ISO Calibration
The CO2 / Room Climate Data Logger PCE-AQD 20 is an ideal measuring device for monitoring the air quality at workplaces. The health and CO2 data logger is ideal for continuous logging of air temperature, humidity, CO2, PM2.5 and air pressure.

Measuring function
  • PM2.5
  • Humidity
  • Temperature
  • CO2
  • Air pressure
  • Memory: SD card max. 32 GB
  • Ideal for workplace monitoring
  • Alarm function
  • Incl. ISO calibration certificate
Power Data Logger PCE-GPA 62
£ 852.00
Price excl. VAT &. delivery

The power data logger (Graphic Power Quality Analyzer) PCE-GPA 62 is used for single-phase or three-phase measurements of the active, reactive and apparent power, power factor, phase angle, energy, voltage, current as well as peaks and harmonics.


  • Real-time test, register and measurement of voltage and current (real and effective) 
  • Measures power factor and phase angle, frequency, energy, active, reactive and apparent power   (single-phase or three-phase in symmetrical networks). 
  • Max. conductor diameter: 55 mm / 2.2 in
  • Records up to 50,000 records