Class 2 Data Logging Sound Level Meter PCE-428
£ 1,030.00
Price excl. VAT &. delivery

PCE-428 is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).

  • Measuring range: 25 … 136 db(A)
  • LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
  • Frequency weighting: A, B, C and Z
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)

Class 2 Data-Logging Decibel Meter PCE-428
£ 1,030.00
Price excl. VAT &. delivery

PCE-428 is a class 2 data-logging decibel meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time.

  • Measuring range: 25 … 136 db(A)
  • A, B, C and Z frequency weightings
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • Adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)

Class 2 Data-Logging Noise Meter / Sound Meter PCE-428
£ 1,030.00
Price excl. VAT &. delivery

PCE-428 is a class 2 data-logging noise meter / sound meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time.

  • Measuring range: 25 … 136 db(A)
  • A, B, C and Z frequency weightings
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • Adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)

Class 2 Data-Logging SPL Meter PCE-428
£ 1,030.00
Price excl. VAT &. delivery

PCE-428 is a class 2 data-logging sound pressure level (SPL) meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter has a large easy-to-read illuminated LCD screen that displays the SPL numerically and graphically in real time.

  • Measuring range: 25 … 136 db(A)
  • A, B, C and Z frequency weightings
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • Adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)

Condition Monitoring Sound Level Meter PCE-428
£ 1,030.00
Price excl. VAT &. delivery

The Condition Monitoring Sound Level Meter is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy Condition Monitoring Sound Level Meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The Condition Monitoring Sound Level Meter calculates the equivalent continuous sound level Leq (LXeq).

  • Measuring range: 25 … 136 db(A)
  • LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
  • Frequency weighting: A, B, C and Z
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)

 

Data Logger with USB Interface PCE-428
£ 1,030.00
Price excl. VAT &. delivery

The data logger with USB interface is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy data logger with USB interface has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).

  • Measuring range: 25 … 136 db(A)
  • LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
  • Frequency weighting: A, B, C and Z
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)

Environmental Meter PCE-428
£ 1,030.00
Price excl. VAT &. delivery

The environmental meter is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy environmental meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).

  • Measuring range: 25 … 136 db(A)
  • LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
  • Frequency weighting: A, B, C and Z
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)

Environmental Tester PCE-428
£ 1,030.00
Price excl. VAT &. delivery

The environmental tester is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy environmental tester has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level tester calculates the equivalent continuous sound level Leq (LXeq).

  • Measuring range: 25 … 136 db(A)
  • LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
  • Frequency weighting: A, B, C and Z
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)

Sound Level Data Logger PCE-428
£ 1,030.00
Price excl. VAT &. delivery

The Data Logger PCE-428 is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy data logger has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The data logger calculates the equivalent continuous sound level Leq (LXeq).

  • Measuring range: 25 … 136 db(A)
  • LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
  • Frequency weighting: A, B, C and Z
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)

Digital Universal Indicator PCE-BPD-U-41A
£ 1,025.00
Price excl. VAT &. delivery
The digital universal indicator is designed in such a way that the measured values displayed can be read from a large distance. With a digit height of 60 mm or 100 mm (2.3" or 3.9"), the reading distance for digital universal indicator is 25 m or 50 m (82 ft or 164 ft).

  • Function: convert analog signal into usable value
  • Input signal: 4 … 20 mA, ±20 mA DC, 0 … 10 V DC, ±10 V DC
  • Display range: -1999 … 9999
  • Digit height: 100 mm / 3.9"
  • Number of outputs: 2
  • Voltage supply: 85 … 265 V AC / 120 … 370 V DC
Digital Universal Indicator PCE-BPD-U-41D
£ 1,025.00
Price excl. VAT &. delivery
The digital universal indicator is designed in such a way that the measured values displayed can be read from a large distance. With a digit height of 60 mm or 100 mm (2.3" or 3.9"), the reading distance for digital universal indicators is 25 m or 50 m (82 ft or 164 ft).

  • Function: convert analog signal into usable value
  • Input signal: 4 … 20 mA, ±20 mA DC, 0 … 10 V DC, ±10 V DC
  • Display range: -1999 … 9999
  • Digit height: 100 mm / 3.9"
  • Number of outputs: 2
  • Voltage supply: 11 … 36 V DC
Panel Meter PCE-BPD-U-41A
£ 1,025.00
Price excl. VAT &. delivery
The panel meter is designed in such a way that the measured values displayed can be read from a large distance. With a digit height of 60 mm or 100 mm (2.3" or 3.9"), the reading distance for panel meter is 25 m or 50 m (82 ft or 164 ft).

  • Function: convert analog signal into usable value
  • Input signal: 4 … 20 mA, ±20 mA DC, 0 … 10 V DC, ±10 V DC
  • Display range: -1999 … 9999
  • Digit height: 100 mm / 3.9"
  • Number of outputs: 2
  • Voltage supply: 85 … 265 V AC / 120 … 370 V DC
Panel Meter PCE-BPD-U-41D
£ 1,025.00
Price excl. VAT &. delivery
The panel meter is designed in such a way that the measured values displayed can be read from a large distance. With a digit height of 60 mm or 100 mm (2.3" or 3.9"), the reading distance for panel meters is 25 m or 50 m (82 ft or 164 ft).

  • Function: convert analog signal into usable value
  • Input signal: 4 … 20 mA, ±20 mA DC, 0 … 10 V DC, ±10 V DC
  • Display range: -1999 … 9999
  • Digit height: 100 mm / 3.9"
  • Number of outputs: 2
  • Voltage supply: 11 … 36 V DC
Absolute Moisture Meter PCE-MA 100
£ 1,023.00
Price excl. VAT &. delivery

The absolute moisture meter PCE-MA 100 allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the absolute moisture meter dries the material to be weighed, and then calculates the moisture content from the weight difference.


  • Testing or weighing capacity: 110 g / 3.88 oz
  • Readability: 1 mg / 0.001 g / 0.01 %
  • Adjustable drying temperature and time

Analytical Balance PCE-MA 100
£ 1,023.00
Price excl. VAT &. delivery

The analytical balance PCE-MA 100 allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the analytical balance dries the material to be weighed, and then calculates the moisture content from the weight difference.


  • Testing or weighing capacity: 110 g / 3.88 oz
  • Readability: 1 mg / 0.001 g / 0.01 %
  • Adjustable drying temperature and time

Benchtop Scale PCE-MA 100
£ 1,023.00
Price excl. VAT &. delivery

The benchtop scale PCE-MA 100 allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the benchtop scale dries the material to be weighed, and then calculates the moisture content from the weight difference.


  • Testing or weighing capacity: 110 g / 3.88 oz
  • Readability: 1 mg / 0.001 g / 0.01 %
  • Adjustable drying temperature and time

Coating Thickness Gauge PCE-CT 80HP-F5N3-ICA incl. ISO-Calibration Certificate
£ 1,023.00
Price excl. VAT &. delivery
ISO Calibration
The paint gauge can reliably determine the thicknessHigh Accuracy of, for example, plastics, paints and other coatings on ferrous and non-ferrous metals. With a measuring range of up to 5000 µm on ferrous metals, the paint gauge covers a wide range of measuring tasks.

  • Measuring range: Fe: 0 … 5000 µm, NFe: 0 … 3000 µm
  • Accuracy after foil calibration: ±(1.5 % of measured value + 1 µm)
  • Data memory for 2000 readings
  • Fe substrates such as: steel and iron
  • NFe substances such as: aluminum and copper
  • Practical V-groove on the measuring heads
  • incl. ISO-Calibration Certificate
Humidity Detector PCE-MA 100
£ 1,023.00
Price excl. VAT &. delivery

The humidity detector allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the humdity detector dries the material to be weighed, and then calculates the moisture content from the weight difference.


  • Testing or weighing capacity: 110 g / 3.88 oz
  • Readability: 1 mg / 0.001 g / 0.01 %
  • Adjustable drying temperature and time

LAB Scale PCE-MA 100
£ 1,023.00
Price excl. VAT &. delivery

The LAB Scale PCE-MA 100 allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the laboratory balance dries the material to be weighed, and then calculates the moisture content from the weight difference.


  • Testing or weighing capacity: 110 g / 3.88 oz
  • Readability: 1 mg / 0.001 g / 0.01 %
  • Adjustable drying temperature and time

Laboratory Balance PCE-MA 100
£ 1,023.00
Price excl. VAT &. delivery

The laboratory balance PCE-MA 100 allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the laboratory balance dries the material to be weighed, and then calculates the moisture content from the weight difference.


  • Testing or weighing capacity: 110 g / 3.88 oz
  • Readability: 1 mg / 0.001 g / 0.01 %
  • Adjustable drying temperature and time

Moisture Analyzing Balance PCE-MA 100
£ 1,023.00
Price excl. VAT &. delivery

PCE-MA 100 is an oven-drying moisture analyzer or moisture balance for weighing and heating material samples to determine moisture content. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the moisture analyzer or moisture balance dries the sample to be weighed, and then calculates the moisture content from the weight difference.


  • Testing or weighing sample capacity: 110 g / 3.88 oz
  • Moisture content measurement range: 0 … 100 %
  • Readout, readability or resolution: 1 mg / 0.001 g / 0.01 %
  • Adjustable drying temperature and time
  • Memory for up to 15 drying programs

Moisture Meter PCE-MA 100
£ 1,023.00
Price excl. VAT &. delivery

The moisture meter PCE-MA 100 allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by a halogen lamp up to 199 °C. In this chamber, the moisture meter dries the material to be weighed, and then calculates the moisture content from the weight difference.


  • Testing or weighing capacity: 110 g / 3.88 oz
  • Readability: 1 mg / 0.001 g / 0.01 %
  • Adjustable drying temperature and time

Multifunction Moisture Analyzer PCE-MA 100
£ 1,023.00
Price excl. VAT &. delivery

PCE-MA 100 is an oven-drying moisture analyzer for weighing and heating material samples to determine moisture content. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the moisture analyzer or moisture balance dries the sample to be weighed, and then calculates the moisture content from the weight difference.


  • Weighing range110 g / 3.88 oz
  • Moisture content measurement range: 0 … 100 %
  • Resolution: 1 mg / 0.001 g / 0.01 %
  • Adjustable drying temperature and time
  • Memory for up to 15 drying programs

Precision Balance PCE-MA 100
£ 1,023.00
Price excl. VAT &. delivery

The precision balance PCE-MA 100 allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the precision balance dries the material to be weighed, and then calculates the moisture content from the weight difference.


  • Testing or weighing capacity: 110 g / 3.88 oz
  • Readability: 1 mg / 0.001 g / 0.01 %
  • Adjustable drying temperature and time

Relative Humidity Meter PCE-MA 100
£ 1,023.00
Price excl. VAT &. delivery

The relative humidity meter PCE-MA 100 allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the relative humidity meter dries the material to be weighed, and then calculates the moisture content from the weight difference.


  • Testing or weighing capacity: 110 g / 3.88 oz
  • Readability: 1 mg / 0.001 g / 0.01 %
  • Adjustable drying temperature and time

Tabletop Scale PCE-MA 100
£ 1,023.00
Price excl. VAT &. delivery

The tabletop scale PCE-MA 100 allows different materials to be weighed and their moisture contents determined. The heating chamber is heated by halogen lamps up to 199 °C. In this chamber, the benchtop scale dries the material to be weighed, and then calculates the moisture content from the weight difference.


  • Testing or weighing capacity: 110 g / 3.88 oz
  • Readability: 1 mg / 0.001 g / 0.01 %
  • Adjustable drying temperature and time

Condition Monitoring Thickness Meter PCE-TG 300-NO5-ICA incl. ISO Calibration Certificate
£ 1,021.00
Price excl. VAT &. delivery
ISO Calibration

The PCE-TG 300-NO5 is a condition monitoring thickness meter for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the condition monitoring thickness meter. Wall thicknesses under a coating can also be measured with the condition monitoring thickness meter.

  • Measuring range: 1 … 600 mm / 0.039 … 23.62" (steel)
  • Diameter: 10mm / 0.39"
  • Minimum diameter of pipes: 20 x 3 mm / 0.787 … 0.118"
  • Frequency: 5 MHz
  • Bluetooth
  • incl. ISO calibration certificate

 

IoT Meter PCE-TG 300-NO5-ICA incl. ISO calibration certificate
£ 1,021.00
Price excl. VAT &. delivery
ISO Calibration

The PCE-TG 300-NO5 is an IoT meter for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the IoT meter. Wall thicknesses under a coating can also be measured with the IoT meter.

  • Measuring range: 1 … 600 mm / 0.039 … 23.62" (steel)
  • Diameter: 10mm / 0.39"
  • Minimum diameter of pipes: 20 x 3 mm / 0.787 … 0.118"
  • Frequency: 5 MHz
  • Bluetooth
  • incl. ISO calibration certificate

Material Tester PCE-TG 300-NO5-ICA incl. ISO calibration certificate
£ 1,021.00
Price excl. VAT &. delivery
ISO Calibration

The PCE-TG 300-NO5 is a material tester for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the material tester. Wall thicknesses under a coating can also be measured with the material tester.

  • Measuring range: 1 … 600 mm / 0.039 … 23.62" (steel)
  • Diameter: 10mm / 0.39"
  • Minimum diameter of pipes: 20 x 3 mm / 0.787 … 0.118"
  • Frequency: 5 MHz
  • Bluetooth
  • incl. ISO calibration certificate

Material Thickness Meter PCE-TG 300-NO5-ICA incl. ISO calibration certificate
£ 1,021.00
Price excl. VAT &. delivery
ISO Calibration

The PCE-TG 300-NO5 is a material thickness meter for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the material thickness meter. Wall thicknesses under a coating can also be measured with the material thickness meter.

  • Measuring range: 1 … 600 mm / 0.039 … 23.62" (steel)
  • Diameter: 10mm / 0.39"
  • Minimum diameter of pipes: 20 x 3 mm / 0.787 … 0.118"
  • Frequency: 5 MHz
  • Bluetooth
  • incl. ISO calibration certificate

NDT Test Instrument PCE-TG 300-NO5-ICA incl. ISO calibration certificate
£ 1,021.00
Price excl. VAT &. delivery
ISO Calibration

The PCE-TG 300-NO5 is an NDT test instrument for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the NDT test instrument. Wall thicknesses under a coating can also be measured with the NDT test instrument.

  • Measuring range: 1 … 600 mm / 0.039 … 23.62" (steel)
  • Diameter: 10mm / 0.39"
  • Minimum diameter of pipes: 20 x 3 mm / 0.787 … 0.118"
  • Frequency: 5 MHz
  • Bluetooth
  • incl. ISO calibration certificate

Paint Thickness Tester PCE-TG 300-NO5-ICA incl. ISO calibration certificate
£ 1,021.00
Price excl. VAT &. delivery
ISO Calibration

The PCE-TG 300-NO5 is a paint thickness tester for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the paint thickness tester. Wall thicknesses under a coating can also be measured with the paint thickness tester.

  • Measuring range: 1 … 600 mm / 0.039 … 23.62" (steel)
  • Diameter: 10mm / 0.39"
  • Minimum diameter of pipes: 20 x 3 mm / 0.787 … 0.118"
  • Frequency: 5 MHz
  • Bluetooth
  • incl. ISO calibration certificate

Thickness Gauge PCE-TG 300-NO5-ICA incl. ISO calibration certificate
£ 1,021.00
Price excl. VAT &. delivery
ISO Calibration

The PCE-TG 300-NO5 is a thickness gauge for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the thickness gauge. Wall thicknesses under a coating can also be measured with the thickness gauge.

  • Measuring range: 1 … 600 mm / 0.039 … 23.62" (steel)
  • Diameter: 10mm / 0.39"
  • Minimum diameter of pipes: 20 x 3 mm / 0.787 … 0.118"
  • Frequency: 5 MHz
  • Bluetooth
  • incl. ISO calibration certificate

Thickness Meter PCE-TG 300-NO5-ICA incl. ISO calibration certificate
£ 1,021.00
Price excl. VAT &. delivery
ISO Calibration

The PCE-TG 300-NO5 is a thickness meter for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the thickness meter. Wall thicknesses under a coating can also be measured with the thickness meter.

  • Measuring range: 1 … 600 mm / 0.039 … 23.62" (steel)
  • Diameter: 10mm / 0.39"
  • Minimum diameter of pipes: 20 x 3 mm / 0.787 … 0.118"
  • Frequency: 5 MHz
  • Bluetooth
  • incl. ISO calibration certificate

Ultrasonic testing device PCE-TG 300-NO5-ICA incl. ISO calibration certificate
£ 1,021.00
Price excl. VAT &. delivery
ISO Calibration

The PCE-TG 300-NO5 is an Ultrasonic testing device for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the Ultrasonic testing device. Wall thicknesses under a coating can also be measured with the Ultrasonic testing device.

  • Measuring range: 1 … 600 mm / 0.039 … 23.62" (steel)
  • Diameter: 10mm / 0.39"
  • Minimum diameter of pipes: 20 x 3 mm / 0.787 … 0.118"
  • Frequency: 5 MHz
  • Bluetooth
  • incl. ISO calibration certificate

 

Ultrasonic Thickness Gauge PCE-TG 300-NO5-ICA incl. ISO calibration certificate
£ 1,021.00
Price excl. VAT &. delivery
ISO Calibration

The PCE-TG 300-NO5 is an ultrasonic thickness gauge for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the ultrasonic thickness gauge. Wall thicknesses under a coating can also be measured with the ultrasonic thickness gauge.

  • Measuring range: 1 … 600 mm / 0.039 … 23.62" (steel)
  • Diameter: 10mm / 0.39"
  • Minimum diameter of pipes: 20 x 3 mm / 0.787 … 0.118"
  • Frequency: 5 MHz
  • Bluetooth