2 year Warranty
The Thermal Camera PCE-TC 28 was designed for taking non-contact temperature measurements. To get accurate readings, the emissivity of the thermal camera can be adjusted, depending on the operation purpose. Besides taking infrared images, the camera can also take normal pictures, as well as a mixture of both, due to the built-in digital camera. This kind of test instruments help electricians and and maintenance workes in condition monitoring.
- Measurement range: -20 ... +600°C / -4 ... 1112°F
- Accuracy: ± 2%, ± 2°C / 3.6°F
- Frequency image recording: 9 Hz
- Camera: 32 x 31 Pixel
PCE-322A is a handheld, portable, professional Class II sound test instrument, sound level meter or decibel (dB) meter with built-in data-logging or data-recording functionality. Thus, PCE-322A is ideal for real-time noise measurement as well as for long-term noise exposure monitoring over time.
- Sound measuring range: 30 ...130 dB
- Resolution: 0.1 dB
- Accuracy: ±1.4 dB
- Memory: Stores up to 32,700 readings
- Sampling rate: 2 times per second
- ISO calibration available as an option
PCE-CT 65 is a coating thickness test instrument that uses magnetic induction (ferrous) or eddy current (non-ferrous) to take non-destructive measurements of coating and dry film thickness (DFT) on metal substrates such as steel and aluminum. This thickness gauge is ideal for painted and powder-coated surface testing, automotive paint inspection, coated material testing, and manufacturing quality control applications.
- Measuring range of 0 ... 1350 µm / 0 ... 53 mils
- Accuracy of ±2.5 % ±2 µm for 0 ... 1000 µm / ±3.5 % for 1000 µm ... 1350
µm / ±2 % ±0.08 mils for 0 ... 39.3 mils / ±3.5 % for 39.3 mils ...
53.1 mils
- Saves up to 1500 measurements to memory
PCE-CT 27FN is a Thickness Test Instrument that takes non-destructive measurements of nonmagnetic coating, insulating layer and dry film thickness (DFT) on metal substrates such as steel and aluminum. Ideal for surface testing, automotive paint inspection, material testing and manufacturing quality control applications.
- Measuring range of 0 ... 1250 µm / 0 ... 50 mils
- Accuracy of ±(2 % + 2 µm) / ±(2 % + 0.1 mils)
- Features a resolution of 0.1 µ / 0.1 mils
PCE-CS 1000N is a digital, electronic, battery-powered Force Test Instrument that displays measurement values in kilograms (kg) or pounds (lbs). The scale comes factory calibrated and includes a hook, shackle and remote control. For an additional fee, the scale can be calibrated according to ISO standards.
- Maximum weighing capacity: 1000 kg / 2200 lbs ≈ 1 Ton
- Resolution: 0.2 kg
- Tare range: 100% full scale
PCE-VA 20 is a multifunction airflow test instrument for assessing wind, weather, indoor / outdoor environmental climate conditions as well as for testing heating, ventilation and air conditioning or cooling (HVAC) systems. This combination anemometer-hygrometer-thermometer features a 10 cm / 3.9" Ø fan impeller, easy-to-read backlit LCD, and functions such as display hold, average value, maximum value, minimum value, battery-saving automatic power off, low-battery indicator, and metric or imperial unit selection.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±(3% of measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1
- CIE L*a*b*C*h, CIE L*a*b*
- Measuring geometry 8°/d
- white calibration
- Stores 100 reference values and 20,000 samples
- measuring aperture is 8 mm
- optional liquid sample kit listed under accessories
PCE-ATP 1 is a food safety / hygiene - ATP test instrument, ATP meter, lumitester or luminometer used for surface testing. This luminometer allows for quick and easy first-generation adenosine triphosphate (ATP) testing and monitoring to ensure proper cleanliness, sterilization and sanitization. PCE-ATP 1 is an ATP tester that can be used for cleanliness control and documentation in many different applications.
- Measurement range: 0 ... 999,999 relative light units (RLUs)
- Stores up to 10,000 date and time-stamped data records to internal memory
- Enables rapid detection of bacterial or microbial residue
- Measurement geometry: 60° degree angle
- Measurement up to 1000 gloss units
- Internal reading memory up to 5000 readings
- 3.5" TFT display
- Light source: D65
- Wave length: 400-700 nm
The Leeb Hardness Test Instrument PCE-900 measures the hardness of nine different metals using the Leeb rebound method.
This means that with the hardness test instrument a firing pin bounces on a metallic surface and the intensity of the rebound is used as an indicator of the material hardness.
The hardness test instrument PCE-900 measures the metal hardness in 6 different hardness scales.
- Measurement according to Leeb Rebound method
- Testing of HRC, HRB, HV, HB, HSD
- Measurement Range: 200-900 HLD / 13-99 HRB / 20-68 HRC / 20-655 HB / 80-940 HV / 32-99 HSD
- Accuracy: 0.80% / Repeatability: 1.10%
- Incl. type D Leeb probe
- Optional Software Available
PCE-HT-225A is a heavy-duty concrete hardness tester or concrete test hammer, also called a concrete rebound hammer or Swiss hammer, used to measure surface hardness and material compression strength. Suitable for use with concrete, rock and building materials, this rugged, manufacturer-calibrated rebound hammer is both easy to use and built to last.
- Test range: 10 ... 60 MPa or 100 ... 600 kg/cm² or 1450 ... 8702 psi
- Impact energy: 2.207 J or N-m / 0.225 kgf.m / 1.6278 ft-lb or Type N
- Impact stroke: 75 ± 0.3 mm / 2.95 ± 0.012 in
- Radius of spherical tip: 25 ± 1 mm / 0.99 ± 0.04 in
- kg/cm², psi, and MPa conversion tables
- Optional test anvil to verify accuracy listed under accessories
PCE-330 is a multifunction heat stress meter or humidity test instrument with a quick-response sensor for determining ambient temperature, relative humidity and dew point temperature. Equipped with an easy-to-read dual display, this data-logging indoor air quality (IAQ) meter features a large internal memory with storage for up to 16,000 recorded values.
- Temperature range: -20 ... 60°C / -4 ... 140°F
- Relative humidity range: 0 ... 100% RH
- Resolution: 0.1° / 0.18°F
- Accuracy: ± 0.8°C / ± 1.5°F, ± 2.0 ... 4.0% RH
- Internal memory: up to 16,000 date- and time-stamped readings