Skip to main content
Ultrasonic testing device PCE-LDC 8
£ 1,451.00
Price excl. VAT &. delivery
The Ultrasonic testing device is used to locate leaks on compressed air lines. Furthermore, the Ultrasonic testing device can also be used on coolant lines or gas lines for leak detection.

  • Measuring principle: ultrasound
  • Measuring principle: air, coolant, non-explosive gases
  • Working frequency of 40 kHz
  • up to 6 h battery operation 
  • Leak detection via headphones and LCD display
  • Localize leaks up to 18m, 59 ft.
Ultrasonic testing device PCE-TDS 75
£ 1,446.00
Price excl. VAT &. delivery
The Ultrasonic testing device is a fixed installation meter. The flow rate of liquids in pipes can be determined with this Ultrasonic testing device. The sensors from the Ultrasonic testing device can be mounted directly on the pipes to be measured without having to cut them open.

  • Measuring range: ± 0.03 … ± 5 m / s
  • Measuring accuracy: ± 1% of the measured value
  • Pipe diameter: 25 … 1200 mm (1 … 48 in)
  • Interface: RS232 & RS485
  • Relay output
Ultrasonic testing device PCE-UFM 65CU
£ 1,446.00
Price excl. VAT &. delivery
Our Ultrasonic testing device enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on copper pipes with a diameter between 59 and 67 mm. The Ultrasonic testing device of the PCE-UFM-CU series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for copper pipes
  • pipe size: DN65 (59 ... 67 mm)
Ultrasonic testing device PCE-UFM 65PVC
£ 1,446.00
Price excl. VAT &. delivery
Our Ultrasonic testing device enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on PVC pipes with a diameter between 72 and 80 mm. The Ultrasonic testing device of the PCE-UFM-PVC series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for PVC pipes
  • pipe size: DN65 (72 ... 80 mm)
Ultrasonic testing device PCE-UFM 50CU
£ 1,357.00
Price excl. VAT &. delivery
Our Ultrasonic testing device enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on copper pipes with a diameter between 46 and 54 mm. The Ultrasonic testing device of the PCE-UFM-CU series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for copper pipes
  • pipe size: DN50 (46 ... 54 mm)
Ultrasonic testing device PCE-UFM 50PVC
£ 1,357.00
Price excl. VAT &. delivery
Our Ultrasonic testing device enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on PVC pipes with a diameter between 59 and 67 mm. The Ultrasonic testing device of the PCE-UFM-PVC series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for PVC pipes
  • pipe size: DN50 (59 ... 67 mm)
Ultrasonic testing device PCE-TG 300-P5EE-ICA incl. ISO calibration certificate
£ 1,282.00
Price excl. VAT &. delivery
ISO Calibration

The PCE-TG 300-P5EE is an Ultrasonic testing device for measuring wall thickness. In general, the wall thicknesses of all homogeneous materials can be measured with the Ultrasonic testing device. Wall thicknesses under a coating can also be measured with the Ultrasonic testing device.

  • Measuring range: P-E: 2 … 600 mm / 0.07 … 23.62", E-E: 2.5 … 100 mm / 0.09 …3.93"
  • Diameter: 10mm / 0.39"
  • Minimum diameter of pipes: 20 x 3 mm / 0.787 … 0.118"
  • Frequency: 5MHz
  • Bluetooth
  • incl. ISO calibration certificate

 

Ultrasonic testing device PCE-UFM 40CU
£ 1,246.00
Price excl. VAT &. delivery
Our Ultrasonic testing device enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on copper pipes with a diameter between 35 and 43 mm. The Ultrasonic testing device of the PCE-UFM-CU series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for copper pipes
  • pipe size: DN40 (35 ... 43 mm)
Ultrasonic testing device PCE-UFM 40PVC
£ 1,246.00
Price excl. VAT &. delivery
Our Ultrasonic testing device enables the measurement of flow velocity from 0.03 to 5 m/s. It can be used for measurements on PVC pipes with a diameter between 46 and 54 mm. The Ultrasonic testing device of the PCE-UFM-PVC series uses the ultrasonic transit time method to determine velocity and flow volume.

  • flow rate: 0.03 ... 5 m/s
  • accuracy: ±2 % of Rd
  • resolution: 0.01 m/s
  • repeatability: 0.2 %
  • display of the volume flow
  • for PVC pipes
  • pipe size: DN40 (46 ... 54 mm)