The Probe Thermometer is suitable for fast, non-contact temperature measurement during servicing and maintenance work in mechanical and plant engineering, in heating, ventilation and air-conditioning systems, and for checking surfaces in various industrial applications. The Probe Thermometer enables measurements in the range from -50 … 800°C. It also features a Type K input for contact measurements from -50 … 1370°C.
With a response time of 150 ms, the Probe Thermometer enables rapid recording of temperature values. The 16:1 optical ratio allows measurements from a greater distance, while the circular laser targeting supports precise alignment with the measuring point. The emissivity can be adjusted from 0.10 … 1.0, allowing it to be adapted to different surfaces. HOLD, MAX, MIN, DIF and AVG functions, as well as upper and lower limit alarms, are available for checking measured values.
The Probe Thermometer features a backlit LCD and allows selection between °C and °F. Automatic switch-off, an out-of-range indicator and a trigger lock for continuous measurements complete its features. Power is supplied by two 1.5V AAA batteries. With an IP54 rating and robust construction, the Probe Thermometer is suitable for flexible use in industry, servicing and maintenance.
| Type K temperature | |
| Measuring range | -50 ... 0 °C |
| Resolution | 0,1 °C |
| Accuracy | ±2 °C |
| Type K temperature | |
| Measuring range | 0 ... 1000 °C |
| Resolution | 0,1 °C |
| Accuracy | ±0.5% of reading or ±1.5°C (larger value applies) |
| Type K temperature | |
| Measuring range | 1000 ... 1370 °C |
| Resolution | 1 °C |
| Accuracy | ±0.5% of reading or ±1.5°C (larger value applies) |
| Type K temperature | |
| Measuring range | -58 ... +32 °F |
| Resolution | 0,1 °F |
| Accuracy | 3.6°F |
| Type K temperature | |
| Measuring range | 32 ... 1832 °F |
| Resolution | 0,1 °F |
| Accuracy | ±0.5% or 3°F (larger value applies) |
| Type K temperature | |
| Measuring range | 1832 ... 2498 °F |
| Resolution | 1 °F |
| Accuracy | ±0.5% or 3°F (larger value applies) |
| Infrared temperature | |
| Measuring range | -50 ... +20 °C |
| Resolution | 0,1 °C |
| Accuracy | ±3.5°C |
| Infrared temperature | |
| Measuring range | 20 ... 300 °C |
| Resolution | 0,1 °C |
| Accuracy | ±1.0% of reading or ±1.0°C (larger value applies) |
| Infrared temperature | |
| Measuring range | 300 ... 800 °C |
| Resolution | 0,1 °C |
| Accuracy | ±1.5% f.s. |
| Infrared temperature | |
| Measuring range | -58 ... +68 °F |
| Resolution | 0,1 °F |
| Accuracy | ±6.3°F |
| Infrared temperature | |
| Measuring range | 68 ... 572 °F |
| Resolution | 0,1 °F |
| Accuracy | ±1% of reading or ±1.8°F (larger value applies) |
| Infrared temperature | |
| Measuring range | 572 ... 1472 °F |
| Resolution | 1 °F |
| Accuracy | ±1.5% of full scale |
| General technical data | |
| Measuring functions | MIN, MAX, HOLD, AVG, DIF |
| Display type | LC colour display with backlight |
| Display size | 1,6 Inch |
| Response time | 150 mS |
| Measurement spot | 16:1 |
| Laser | Class 2 <1mW |
| Alarm modes | Upper value Lower value |
| Repeatability | ±1.8°C (±3.2°F) @ -50 ... 20°C (-31 ... 68°F) ±0.5% or ±0.5°C (±0.9°F) @ 20 ... 800°C (68 ... 1472°F) |
| Emissivity from/to | 0.1 ... 1 |
| Spectral range | 8 ... 14 µm |
| Wavelength range | 630 ... 670 Nm |
| Menu language | English, English (GB) |
| Protection class (device) | IP54 |
| Power supply | batteries |
| (Rechargeable) battery | 2 x 1,5 V AAA battery , Alkali-manganese |
| Capacity | 1270 mAh |
| Performance | 1,91 Wh |
| Operating conditions | 0 ... 50 °C , 10 ... 90 % RH |
| Storage conditions | -10 ... 60 °C , 0 ... 80 % RH |
| Dimensions ( L x W x H ) | 175 x 50 x 98 mm |
| Weight | 219 g |