Description

HVAC Meter / HVACR Tester with True RMS / Auto Range / LED Torch / Auto Power-Off / 2-inch LCD Display / Compact Design

The HVAC Meter / HVACR Tester is suitable for measurements and tests in electrical measurement technology, during maintenance work, installations and fault finding on electrical systems. It measures DC and AC current from 1 … 100 A as well as DC and AC voltage from 0.8 … 610V. The resistance measuring range extends from 5 Ω … 40 MΩ. For precise measurement of alternating quantities, the HVAC Meter / HVACR Tester features a True RMS function.

In addition, a continuity test with acoustic signal at <50 Ω, a phase test, a ZERO/null-setting function and non-contact voltage detection are available. Automatic range selection makes it easier to carry out various measuring tasks. The HVAC Meter / HVACR Tester displays readings on an illuminated 2-inch LCD with 4,000 counts.

With a measuring time of 0.4 s, an input impedance of 10 MΩ and a maximum input voltage of 610V AC/DC, the HVAC Meter / HVACR Tester is suited to fast measurements. Automatic power-off after 15 minutes reduces energy consumption. The safety category CAT III 600V allows use for corresponding electrical measurements.


Highlights

- Automatic range selection
- Non-contact voltage detection
- Phase test
- ZERO/null-setting function
- True RMS
- DC voltage
- AC voltage
- DC current
- AC current
- Resistance
- Continuity test

Specification

DC voltage 
Measuring range  0,8 ... 3,999 V
Resolution  0,001 V
Accuracy  ±(0.8 % of Rd +3 digits)
  
DC voltage 
Measuring range  4 ... 39,99 V
Resolution  0,01 V
Accuracy  ±(0.8 % of Rd +3 digits)
  
DC voltage 
Measuring range  40 ... 399,9 V
Resolution  0,1 V
Accuracy  ±(1 % of Rd +5 digits)
  
DC voltage 
Measuring range  400 ... 610 V
Resolution  1 V
Accuracy  ±(1 % of Rd +5 digits)
  
Direct current DC 
Measuring range  1 ... 100 A
Resolution  0,1 A
Accuracy  ±(2.5 % of Rd +5 digits)
  
AC voltage 
Measuring range  0,8 ... 3,999 V
Resolution  0,001 V
Accuracy  ±(1% of Rd +3 digits)
  
AC voltage 
Measuring range  4 ... 39,99 V
Resolution  0,01 V
Accuracy  ±(1% of Rd +3 digits)
  
AC voltage 
Measuring range  40 ... 399,9 V
Resolution  0,1 V
Accuracy  ±(1.2% of reading + 5 digits)
  
Alternating current AC 
Measuring range  1 ... 100 A
Resolution  0,1 A
Accuracy  ±(2.5% of reading + 5 digits)
Frequency range  40 ... 1000 Hz
  
Resistance 
Measuring range  5 ... 3999 Ω
Resolution  1 Ω
Accuracy  ±(1.2% of reading + 8 digits)
  
Resistance 
Measuring range  4 ... 39,99 kΩ
Resolution  0,01 kΩ
Accuracy  ±(1.2% of reading + 3 digits)
  
Resistance 
Measuring range  40 ... 399,99 kΩ
Resolution  0,1 kΩ
Accuracy  ±(1.2% of reading + 3 digits)
  
Resistance 
Measuring range  0,4 ... 3,999 M Ω
Resolution  0,001 M Ω
Accuracy  ±(2% of reading + 10 digits)
  
Resistance 
Measuring range  4 ... 40 M Ω
Resolution  0,01 M Ω
Accuracy  ±(2% of reading + 10 digits)
  
General technical data 
Display type  LCD with backlight
Display size  2 Inch
Automatic power-off  15 min
Operating height  2000 m max. above sea level
Safety standard  CAT III 600V
Measurement time  0,4 s
Measuring range selection  Automatic
Display range  4000 counts
Max. input voltage  610V AC/DC
Input impedance  10 M Ω
Menu language  English, English (GB)
Protection class (device)  IP20
Power supply  5 V DC
(Rechargeable) battery  1 x 3,7 V internal , lithium
Capacity  400 mAh
Performance  1,48 Wh
Operating conditions  0 ... 40 °C , 0 ... 80 % RH
Storage conditions  -10 ... 60 °C , 0 ... 70 % RH
Dimensions ( L x W x H )  192 x 36 x 30 mm
Weight  101 g

Delivery Scope

1 x HVAC Meter / HVACR Tester PCE-CM 2
1 x Test lead set
1 x USB-C cable
1 x Operating manual