Electric Vehicle EV Tester / EV Test Instrument
The Electric Vehicle EV Tester / EV Test Instrument is for VDE 0100 testers to test charging stations (charging mode 3) for electric cars. This adapter can be used with the PCE-ITE 55B installation tester or with most other standard VDE 0100 testers. Thanks to the LEDs for voltage detection on the 3 phases, it can be quickly determined if there is an installation error.
The PP State rotary switch can be used to simulate the current carrying capacity of the charging cable. The current carrying capacity is simulated with various resistors in the Electric Vehicle EV Tester / EV Test Instrument, which are connected between PP and PE conductors. Various vehicle states can be simulated using the CP State rotary switch. The vehicle states are simulated with different resistors connected between the CP and PE conductors.
An external load can be connected to the socket. This output is only intended for measuring purposes and offers the option of checking the function of the electricity meter. The Electric Vehicle EV Tester / EV Test Instrument can also be used to simulate a PE fault (earth fault). The Electric Vehicle EV Tester / EV Test Instrument is supplied in a device bag. There is also an optional adapter for wallboxes with a type 1 connection.
| Test functions | |
| PE pre-test | yes, with capacitive electrode |
| PP simulation | offen, 13 A, 20 A, 32 A, 63 A |
| CP status | A, B, C, D |
| CP error 'E' | E |
| PE fault / earthing fault | Yes |
| General technical data | |
| Outputs | 2 pcs. 4mm sockets (signal output terminals) |
| Cable length | 25 cm |
| Connections | L1, L2, L3, N, PE |
| Connections additional information | max. 230V (1-phase) / 430V (3-phase) ; 50 / 60Hz 10A / 250 V Type 2 plug permanently attached to the cable (optional adaptor required for type 1) |
| Standard(s) | IEC62196-2 type 2 plug |
| Safety standard | CAT II / 300V |
| Mains socket | max. 250 V; 50/60 Hz; 10 A |
| Fuse(s) | Mains socket T10A/250V |
| Protection class (device) | IP40 |
| Operating conditions | 0 ... 40 °C , 0 ... 80 % RH |
| Storage conditions | -10 ... 50 °C , 0 ... 80 % RH |
| Dimensions ( L x W x H ) | 600 x 105 x 73 mm |
| Weight | 643 g |