Gas Detector AQ-500


US$ 1,613.00
AQ-500
ex. VAT, ex. delivery costs
Available in: 10 - 14 days

Description

Gas Detector for measurement of ozone / Many different sensors available /
Broad range of application / Replaceable sensor head / Alarm function / Data logger /
Optional sensor for temperature and humidity


The Gas Detector AQ-500 is a highly accurate instrument for measuring ozone concentrations in the air. The Gas Detector can be equipped with four different heads that vary in their measurement range. Furthermore, the Gas Detector has sensor heads for other gases available, which are automatically recognized when plugged into the device. Thus, you can use the Gas Detector in many different areas. The possibilities of the Gas Detector extend the use of ozone in your processes for bleaching oils, greases, wax, paper, synthetic fibers, cellulose or textiles,within the paper, textile, or lubricant production industries. Another field of application for the Gas Detector is in cleaning, disinfection and sterilisation of swimming pools, water treatment facilities or after fire damage or water damage. With a head for lower measurements of up to 0.150 ppm, you can measure ozone concentrations that have a negative effect on the mental state of humans. Thanks to the leading GSS technology of the sensors, the Gas Detector is not only high precision, but also has a long lifespan. The unique possibility to refresh the sensors makes their maintenance more economical than the maintenance of other types of sensors. Depending on the model, the measured concentrations may be written to the internal memory of the Gas Detector via an analog interface with a 0... 5 V output, or the output is transferred via a USB interface to a PC. Similarly, a remote kit is available as an option, allowing the Gas Detector to take measurements in a secure room while the sensor is connected via cable to the Gas Detector. Through simplicity of operation the alarm thresholds for the optical or acoustic signal can be changed in a very short time. In addition to the measured concentrations in the LCD display, which are displayed in ppm or mg / m³, the high and low alarms are shown.

Attention! No sensor head is included in the delivery, it must be ordered separately as an accessory!


Highlights

- High accuracy and functionality
- Easy to operate and maintain
- Fast response time
- Interchangeable sensor heads
- LCD display
- Battery operation
- Alarm function
- Sensor calibration function
- Max. / Min. / Average function
- Analog output
- Digital output
- Data logger

Specification

Technical Specification of the Gas Detector Ozone Meter
Model 500 Series
As Model 200 and 300 Series, in addition:
Digital outputRS232 with USB converter
Data Logger8188 values
PC transferSoftware and data cable included
Model 200, 300 and 500 Series
Power supply12 V DC
Rechargeable batteryLithium-Polymer 12 V DC / 2700 mAh
Charger12.6V 2 A
Charging voltage12.6V
Charging time2... 3 hours
Lifecycle> 500 charges
HousingPC & ABS / IP20 & NEMA 1
Dimensions (incl. opt. sensorsavailable)7.7 x 4.8 x 2.1 in / 195 x 122 x 54 mm
Weight< 1 lb / 460 g (with battery)
ApprovalsEN 50082-1: 1997, EN 50081-1: 1992, CE

You can find the technical data on a variety of sensor heads to the ozone measurement device AQ series below in the "Optional accessories for ozone meter AQ series".

Delivery Scope

Delivery Contents of the Gas Detector
1 x Basic device AQ-500
1 x 12V DC 800 mA AC/DC Power Supply Unit
1 x Battery pack 12V
1 x Software und data cable (USB)
1 x Operating instructions.

Attention! No sensor head is included in the delivery, it must be ordered separately as an accessory!


Optional accessories for Gas DetectorAQ series:

Sensors:

Gas:
CodeMeasuring range (ppm)Min.
(ppm)Accuracy
(ppm)Resolution 
(ppm)Temp. °C/ Humid. %
GSS-Sensors (semiconductors sensors):
Ozone 
(O3)  OZU0 ... 0.150.001< ±0.005 %0.0010 ... +40 
10 ... 90 
Ozone 
(O3) OZL0 ... 0.50.001

< ±0.008 

0 ... 0.1

0.0010 ... +40 
10 ... 90 
Ozone 
(O3) EOZ0 ... 100.01 < ±0.1
0...1 0.010 ... +40 
10 ... 90 
Hydrogen
(H2) HA0 ... 50005< ±10 %10 ... +40 
10 ... 90 
Chlorine
(CL2) ECL0 ... 100.1< ±10 %0.010 ... +40 
10 ... 90 

Ozone (O3) 

Leckfin. OZK

0.010.010 ... +40 
10 ... 90 
Methane 
(CH4) MT0 ... 10,00010< ±15 %10 ... +40 
10 ... 90 
NMHC
VN0 ... 250.1< ±10 % 
0.1 ... 25 0.10 ... +40 
10 ... 90 
Tetrachlorethylene
(C2CL4) PE0 ... 2001< ±5 
0 ... 5010 ... +40 
10 ... 90 
(VOC) 
VM0 ... 250.1±10 %0.10 ... +40 
10 ... 90 
(VOC) 
VP0 ... 5001±10 %10 ... +40 
10 ... 90 

GSE-Sensors (electrochemical sensors):
Ammonia
(NH3) ENG0 ... 1000.2±10 %0.10 ... +40 
10 ... 90 
Carbon monoxide (CO) ECN0 ... 1000.1< ±1 
0... 100.10 ... +40 
10 ... 90 
Carbon monoxide
(CO) ECM0 ... 250.02< ±0.5
0 ... 50.010 ... +40 
10 ... 90 
Formaldehyde
(CH2O) EF0 ... 100.01< ±0.05
0 ... 0.50.010 ... +40 
10 ... 90 
Hydrogen sulfide (H2S) EHS0 ... 100.01< ±0.05
0 ...0.50.010 ... +40 
10 ... 90 
Hydrogen sulfide (H2S) EHT0 ... 1000.2< ±0.5
0 ... 50.10 ... +40 
10 ... 90 
Nitrogen dioxide (NO2) ENW0 ... 10.002< ±0.02 
0 ... 0.10.0010 ... +40 
10 ... 90 
Sulfur dioxide (SO2) ESO0 ... 100.01< ±0.05
0 ... 0.50.010 ... +40 
10 ... 90 
Sulfur dioxide (SO2) ESP0 ... 1000.2< ±0.05
0 ... 0.50.10 ... +40 
10 ... 90 

NDIR-Sensors (infrared sensors):
Carbon dioxide (CO2) CD0 ... 20002< ±5 % 
(the display)10 ... +40 
10 ... 90 
Carbon dioxide (CO2) CE0 ... 50005<± 5 % 
(the display)10 ... +40 
10 ... 90 
Carbon dioxide
(CO2) CF0 ... 5 %0.02 %<± 5 % 
(the display)0.01 %0 ... +40 
10 ... 90 

PID-Sensors (photoionization detector sensors):
VOC 
PDL0 ... 200.01< ±10 %0.010 ... +40 
10 ... 90 
VOC
PDH0 ... 10000.2< ±10 %0.10 ... +40 
10 ... 90 

Combined Sensors:
CO2
CO
PID
Code: MS20 ... 2000
0 ... 100
0 ... 252
0.1
0.01±40  + 3 %
±10 % 1 ...100
±10 % des Erg.1
0.1
0.010 ... +40 
10 ... 90 
CO2
CO
Code: MS10 ... 2000
0 ... 1002
0.1±40  + 3 %
±10 % 1 ...1001
0.10 ... +40 
10 ... 90 