Technical specifications |
|
Measurement range | 0.5 ... 9999 mm (longitudinal shaft steel), continuously adjustable |
Sound velocity | 1000 ... 15000 m/s, continuously adjustable, coarse adjustment |
Display delay | -10 ... 2000 mm |
Probe delay | 0.00 ... 199.9 µs |
Transmitting impulse | 400 V negative signal peaks |
Damping (impulse generator) | 50 / 100 / 200 / 500 |
Work mode | One- or two-probe measurement |
Operating frequency range | 0.5 ... 20 MHz |
Pulse repetition frequency | 40 / 250 /1000 Hz optional |
Amplification / gain (receiver) | 0 ... 110 dB |
Rectification (receiver) | Whole wave, positive half wave, negative half wave, high frequency representation |
Alarm limits | Limit A (Gate A) and Limit B (Gate B), Adjustable as positive or negative peak with automatic (visual or audible) alarm |
Measurement mode | Limit value / Extreme value mode |
Measurement deviation horizontal linearity | ≤0.1 % |
Measurement deviation vertical linearity | ≤3 % |
Excess sensitivity | ≥62 dB |
Dynamic range | ≥40 dB |
Resolution remote field | ≥30 dB |
Sampling rate | 400 MHz |
Measurement data storage | 500 records |
Signal reproduction | Permanent recording of signals with the playback of dynamic echoes |
Surface adjustment | Automatic adjustment of the error position of the angled probes |
Automatic amplification | 20 ... 80 %, in 1 % steps |
Menu language | English, Chinese |
Interface | USB-A, USB-B, Ethernet |
Display | 5.7 " TFT color LCD (640 x 480 pixels) |
Operating temperature | -10 ... +50 °C |
Power supply | AC: 100 ... 240 V DC: 15 V / 4 A |
Battery | Li-ion battery (10.8 V, 5200 mAh) |
Battery opearting time per charge | >6 hours |
Protection class | IP54 |
Weight | 1.4 kg (incl. battery) |
Calibration block PCE-USC-V1 for PCE-USC 20, PCE-USC 30, and PCE-FD 20. Distance, beam index, refracted angle, and sensitivity calibration. In accordance with ASTM E164 specifications. Dimensions are 1" thickness.
- Calibration block for training and test
ex. VAT, ex. delivery costs
Calibration block PCE-USC-V2 for PCE-USC 20, PCE-USC 30, and PCE-FD 20. Distance, beam index, refracted angle, and sensitivity calibration. Contains a 1.0" radius opposite a 2.0" radius, a 5/64" diameter x 0.750" deep flat-bottom hole. In accordance with ASTM E164 specifications. Dimensions are 1" thickness.
- Calibration block for training and test
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs