Measuring range pH | -2.000 ... 19.999 pH |
Resolution | 0.1 / 0.01 pH |
Accuracy | electrode: ±0.02 pH |
Input current | ≤1×10^-12 A |
Input resistance | ≥3×10^12 Ω |
Measurement stability | ±0.01 pH/3h |
Temperature compensation | 0 ... 100 °C / 32 ... 212 °F (automatic / manual) |
Measuring range mV | -1999.9 ... 1999.9 mV |
Resolution | 1 mV |
Accuracy | ±0.03 % of measuring range |
Measuring range temperature | -10 ... 110 °C / 14 ... 230 °F |
Resolution | 0.1 °C |
Accuracy | 5 ... 60 °C (41 ... 140 °F): ±0.4°C |
rest: ±0.8 °C | |
Measuring range conductivity | 0 ... 19.99 µS/cm |
20.0 ... 199.9 µS/cm | |
200 ... 1999 µS/cm | |
2.00 ... 19.99 mS/cm | |
20.0 ... 1999.9 mS/cm | |
Resolution | 0.01 / 0.1/ 1 μS/cm, 0.01 / 0.1 mS/cm |
Accuracy | measuring device: ±0.5 % of measuring range |
in combination with measuring electrode: ±1.0 % of measuring range | |
Temperature compensation | 0 ... 100 °C / 32 ... 212 °F (automatic / manual) |
Adjustable electrode constant | 0.1 / 1 / 10 cm^-1 |
Adjustable reference temperature | 25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F |
Measuring range TDS | 0 ... 100 g/l |
Resolution | 0.001 mg/l |
Accuracy | measuring device: ±0.5 % of measuring range |
in combination with measuring electrode: ±1.0 % of measuring range | |
Temperature compensation | 0 ... 100 °C / 32 ... 212 °F (automatic / manual) |
Adjustable electrode constant | 0.1 / 1 / 10 cm^-1 |
Adjustable reference temperature | 25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F |
Measuring range salinity | 0 ... 100 ppt |
Resolution | 0.1 ppt |
Accuracy | measuring device: ±0.5 % of measuring range |
in combination with measuring electrode: ±1.0 % of measuring range | |
Temperature compensation | 0 ... 100 °C / 32 ... 212 °F (automatic / manual) |
Adjustable electrode constant | 0.1 / 1 / 10 cm^-1 |
Adjustable reference temperature | 25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F |
Measuring range resistance | 0 ... 100 MΩ cm |
Resolution | 0.001 / 0.01 / 0.1 / 1M Ω·cm |
Accuracy | measuring device: ±0.5 % of measuring range |
in combination with measuring electrode: ±1.0 % of measuring range | |
Temperature compensation | 0 ... 100 °C / 32 ... 212 °F (automatic / manual) |
Adjustable electrode constant | 0.1 / 1 / 10 cm^-1 |
Adjustable reference temperature | 25 °C / 77 °F, 20 °C / 68 °F, 18 °C / 64 °F |
Data memory | 300 pH measuring points |
300 conductivity measuring points | |
Content of a memory point | date and time, measured value with unit and temperature |
Display | 7" touchscreen |
Resolution | 1024 x 600 pixels |
Interfaces | USB A |
USB B | |
Bluetooth | |
Power supply | Primary: 230 ... 240 V / 50 Hz |
Secondary: 12 V DC / 1 A | |
Operating conditions | 5 ... 35 °C / 41 ... 95 °F, < 85 % RH not condensing |
IP protection class | IP 54 |
Dimensions | 175 × 220 × 40 mm / 68.9 x 86.6 x 15.7" |
Weight | ca. 310 g / 10.9 lb |
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
ex. VAT, ex. delivery costs
Special pH probe:
- pH range: 0.00 ... 14.00 pH
- Zero point: 7.0 ± 0.5 pH
- Temperature range: 0 ... 60 ° C (32 ... 140 ° C)
- Electrode type: Ag / AgCL / KCL
- Length: 150 mm (6")
- Diameter: 12 mm (0.5")
- Connection: BNC
Applications:
- Cosmetics
- Paint
- Wastewater
- And more
ex. VAT, ex. delivery costs
Calibration Solution pH4, pH7 and pH10. pH electrodes drift over time, causing measurement errors. To ensure high accuracy, we recommend regular calibration of pH meters.
- pH 4, pH 7 and pH 10
- Dosing with certificate
- Various sizes can be selected!
ex. VAT, ex. delivery costs
Calibration Solution pH10. pH electrodes drift over time, causing measurement errors. To ensure high accuracy, we recommend regular calibration of pH meters.
- pH 10.00
- Dosing with certificate
- Various sizes can be selected!
ex. VAT, ex. delivery costs
Calibration Solution pH7. pH electrodes drift over time, causing measurement errors. To ensure high accuracy, we recommend regular calibration of pH meters.
- pH 7.01
- Dosing with certificate
- Various sizes can be selected!
ex. VAT, ex. delivery costs
Calibration Solution pH4. pH electrodes drift over time, causing measurement errors. To ensure high accuracy, we recommend regular calibration of pH meters.
- pH 4.01
- Dosing with certificate
- Various sizes can be selected!
ex. VAT, ex. delivery costs