Current clamp with NCV measurement / Current measurement up to 200 A AC / Frequency measurement directly on the clamp  / Ready for immediate use / Simple operation

The current clamp is a multimeter with a variety of different functions. Current measurements up to 200 A AC can be carried out with the current clamp without contact. This current range of the current clamp covers a wide range of current measurements. Thanks to the contactless current measurements of the current clamp, measurements can be made during operation. This means that there is no need to prepare the current clamp for measurement, as measurements can be taken directly on the cable to be measured.

Another special non-contact feature of the current clamp is the NCV (Not Connected Voltage) measurement. With this measurement, the current clamp can indicate whether a voltage is present on a line. Here, too, the current clamp does not need to be prepared for measurement during operation. These two features of the current clamp thus reduce the risk of injury from electric shock.

Other useful functions of the current clamp are the measurement of resistance and the continuity test. The continuity test of the current clamp can be used, for example, to determine whether a relay in a switch box is fully closed. Thanks to the fast measuring frequency of the current clamp, any current fluctuations can be determined. This makes the current clamp an indispensable tool for every electrician.

Highlights

- Inductive current measurement up to 200 A AC
- Voltage measurement with frequency meter
- "Hold" function for freezing the measured value
- Temperature measurement with thermocouple
- Small and compact design
- Smaller internal resistance with the LowZ function

Specification

Measuring function 
AC / Alternating current 
Measuring rangeResolutionAccuracy
200 A0.1 A±(3.0 % + 3 digits)
Frequency range: 40 ... 400 Hz
Maximum input current: 200 A AC
  
Measuring function 
DC / Direct current 
Measuring rangeResolutionAccuracy
600 µA0.1 µA±(1.0 % + 4 digits)
1000 µA1 µA±(1.0 % + 4 digits)
Maximum input current: 1000 µA
  
Measuring function 
DC voltage 
Measuring rangeResolutionAccuracy
600 mV0.1 mV±(0.7 % + 3 digits)
6 V0.001 V±(0.7 % + 3 digits)
60 V0.01 V±(0.7 % + 3 digits)
600 V0.1 V±(0.7 % + 3 digits)
Input impedance: 10 MΩ
Maximum input voltage: 600 V DC AC rms
   
Measuring function 
AC voltage 
Measuring rangeResolutionAccuracy
6 V0.001 V±(0.8 % + 3 digits)
60 V0.01 V±(0.8 % + 3 digits)
600 V0.1 V±(0.8 % + 3 digits)
Input impedance: 10 MΩ
Maximum input voltage: 600 V DC AC rms
Frequency range: 40 ... 400 Hz
 
Measuring function 
LowZ AC/DC 
Measuring rangeResolution 
Accuracy
600 V0.1 V±(2.0 % + 3 digits)
Input impedance: 10 MΩ
Maximum input voltage: 600 V DC AC rmsS
Frequency range: 40 ... 400 Hz
   
Measuring function 
Resistance 
Measuring rangeResolutionAccuracy
600 Ω0.1 Ω±(0.8 % + 3 digits)
6 kΩ0.001 kΩ±(0.8 % + 3 digits)
60 kΩ0.01 kΩ±(0.8 % + 3 digits)
600 kΩ0.1 kΩ±(0.8 % + 3 digits)
6 MΩ0.001 MΩ±(1.2 % + 3 digits)
60 MΩ0.1 MΩ±(1.2 % + 3 digits)
Test voltage (open circuit): 0.4 V
Surge protection: 250 V AC/DC rms
 
Measuring function 
Continuity test 
Measuring rangeResolutionAccuracy
-0.1 Ω-
Surge protection: 250 V AC/DC rms
Audible signal at <50 Ω
   
Measuring function 
Diode test 
Measuring rangeResolutionAccuracy
-0.001 V-
Surge protection: 250 V AC/DC rms
Forward current: 1 mA DC
Forward voltage: 3.3 V DC
   
Measuring function 
Capacitance 
Measuring rangeResolutionAccuracy
99.99 nF0.01 nF±(4.0 % + 5 digits)
999.9 nF0.1 nF±(4.0 % + 5 digits)
9.999 µF0.001 µF±(4.0 % + 5 digits)
99.99 µF0.01 µF±(4.0 % + 5 digits)
999.9 µF0.1 µF±(4.0 % + 5 digits)
9.999 mF1 µF±(4.0 % + 5 digits)
99.99 mF0.01 mF±(4.0 % + 5 digits)
Surge protection: 250 V AC/DC rms
   
Measuring function 
Temperature (thermocouple type K) 
Measuring rangeResolutionAccuracy
-20 ... 0 °C1 °C±(3.0 % + 2 digits)
1 ... 400 °C1 °C±(2.0 % + 2 digits)
-4 ... 32 °F1 °F±(3.0 % + 4 digits)
33 ... 752 °F1 °F±(2.0 % + 4 digits)
Surge protection: 250 V AC/DC rms
   
Measuring function 
Frequency (with current clamp) 
Measuring rangeResolutionAccuracy
99.99 Hz0.01 Hz
±(1.5 % + 5 digits)
999.9 Hz0.1 Hz±(1.5 % + 5 digits)
>1 kHz0.001 kHzfor reference only
Frequency range: 10 Hz ... 1 kHz
Maximum input current: 200 A AC rms
Input range: > 60 A AC rms (if the input current increases, the frequency also increases)
   
Measuring function 
Frequency (when measuring voltage) 
Measuring rangeResolutionAccuracy
99.99 Hz0.01 Hz±(1.5 % + 5 digits)
999.9 Hz0.1 Hz±(1.5 % + 5 digits)
9.999 Hz0.001 kHz±(1.5 % + 5 digits)
>10 kHz0.01 kHzfor reference only
Frequency range: 10 Hz ... 10 kHz
   
Measuring function 
Frequency (direct measurement) 
Measuring rangeResolutionAccuracy
99.99 Hz0.01 Hz±(0.3 % + 5 digits)
999.9 Hz0.1 Hz±(0.3 % + 5 digits)
9.999 Hz1 Hz±(0.3 % + 5 digits)
99.99 kHz0.01 kHz±(0.3 % + 5 digits)
999.9 kHz0.1 kHz±(0.3 % + 5 digits)
9.999 kHz1 kHz±(0.3 % + 5 digits)
99.99 MHz0.01 MHz±(0.3 % + 5 digits)
   
Measuring range: 10 Hz ... 60 MHz
Input impedance: 10 MΩ
Input range: >0.2 V AC rms (if the input voltage increases, the frequency also increases)
Maximum input voltage: 250 V AC rms
 
Measuring function 
Duty cycle 
Measuring rangeResolutionAccuracy
5 ... 95 %0.1 %±0.3 %
   
More specifications 
Range selectionautomatic and manual
Maximum working height2000 m / 6561 ft
DisplayLC display
Largest display value5999
Overrange
"OL" display
Underrange"-OL" display
Measuring rate3 measurements per second
Automatic shutdownafter 15 minutes of inactivity
Power supply1 x 9 V block battery
Operating conditions0 ... 40 °C / 32 ... 104 °F
Storage conditions-10 ... 50 °C / 14 ... 122 °F
Dimensions201 x 65 x 43 mm / 7.9 x 2.6 x 1.7"
Weight
ca. 265 g / 9.3 oz (with battery)

Delivery Scope

1 x Clamp meter PCE-CM 5
1 x Pair of test leads
1 x Transport bag
1 x 9V Bock battery
1 x User manual