Order no.: PCE-DC 20-ICA

Automotive Tester PCE-DC 20-ICA incl. ISO Calibration Certificate

ISO Calibration
US$ 343.00
PCE-DC 20-ICA
ex. VAT, ex. delivery costs
Available in: 10 - 14 days

Description

Automotive Tester incl. ISO Calibration Certificate
AC / DC digital multimeter with direct frequency measurement on the clamp / LCD display / Automatic shutdown when not in use / Current measurement up to 1000 A / For mobile use / Current clamp opening 40 mm (1.6 in)


The automotive tester is a versatile measuring instrument for the determination of currents, voltages and many other electrical quantities. With a current clamp opening of 40 mm / 1.6 in, even cables with a larger diameter can be tested with the digital multimeter. Thus, with the digital multimeter, current measurements of up to 1000 A AC / DC are possible.

The user can perform frequency measurements with this automotive tester. This ensures contactless frequency measurement with the digital multimeter. Thus, the digital multimeter is a useful addition to the equipment of an electrician.

Highlights

- Current clamp opening 40 mm / 1.6 in
- Backlit LCD display
- Automatic shutdown
- Ready for operation after switching on
- Extensive measuring functions
- Measuring range is selected automatically
- incl. ISO Calibration Certificate

Specification

Measuring function  
DC current  
Measuring range Resolution Accuracy
400 A 0.1 A ±3 % + 5 digits
600 A 1 A
±3 % + 5 digits
1000 A 1 A ±3 % + 6 digits
     
Overvoltage protection: 120% of the measuring range for a maximum of 60 seconds
       
Measuring function  
AC current  
Measuring range Resolution Accuracy
400 A 0.1 A ±3 % + 5 digits
600 A 1 A ±3 % + 5 digits
1000 A 1 A ±3 % + 6 digits
     
Frequency range: 50 ... 60 Hz
Overvoltage protection: 120% of the measuring range for a maximum of 60 seconds
   
Measuring function  
DC voltage  
Measuring range Resolution Accuracy
4 V 1 mV ±0.5 % + 5 digits
40 V 10 mV ±0.5 % + 5 digits
400 V 0.1 V ±0.5 % + 5 digits
600 V 1 V ±1 % + 5 digits
1000 V 1 V ±1 % + 5 digits
     
Input impedance: 10 MΩ
Overvoltage protection: 1000 VDC or 700 VAC RMS
     
Measuring function  
AC voltage  
Measuring range Resolution Accuracy
4 V 1 mV ±1.2 % + 5 digits
40 V 10 mV ±1.2 % + 5 digits
400 V 0.1 V ±1.2 % + 5 digits
600 V 1 V ±2 % + 5 digits
1000 V 1 V ±2 % + 5 digits
     
Input impedance: 10 MΩ
Overvoltage protection: 1000 VDC or 700 VAC RMS
Frequency range: 40 ... 400 Hz
 
Measuring function  
Resistance  
Measuring range Resolution Accuracy
400 Ω 0.1 Ω ±1 % + 5 digits
4 kΩ 1 Ω ±1 % + 5 digits
40 kΩ 10 Ω ±1 % + 5 digits
400 kΩ 0.1 kΩ ±1 % + 5 digits
4 MΩ 1 kΩ ±1 % + 5 digits
40 MΩ 10 kΩ ±2 % + 5 digits
     
Overvoltage protection: 250 V AC/DC RMS
     
Measuring function  
Frequency (direct)  
Measuring range Resolution Accuracy
40 Hz 1 Hz ±0.1 % + 1 digits
400 Hz 1 Hz ±0.1 % + 1 digits
4 kHz 10 Hz ±0.1 % + 1 digits
40 kHz 100 Hz ±0.1 % + 1 digits
100 kHz 100 Hz ±0.1 % + 1 digits
     
Measuring range: 1 ... 10 V RMS, 40 Hz ... 100 kHz
 
Measuring function  
Frequency (current clamp)  
Measuring range Resolution Accuracy
40 Hz 0.01 Hz ±0.1 % + 1 digits
400 Hz 0.1 Hz ±0.1 % + 1 digits
     
Frequency range: 40 ... 400 Hz (>20 A)
   
Further measuring functions  
Continuity test audible signal at <40 Ω
Diode test indicates forward voltage
   
General specifications  
Measuring rate 2 ... 3 measurements per second
Display LCD 3999 Digits
Measuring range selection automatically
Automatic shutdown after 30 minutes of inactivity, deactivatable
Maximum clamp opening 40 mm / 1.6"
Coefficients 0.1 x accuracy x °C*
Maximum voltage 1000 V CAT II, 600 V CAT III
Maximum working height 2000 m / 6561 ft
Operating conditions
5 ... 35 °C / 41 ... 95 °F, <75 % RH
Storage conditions -10 ... 35 °C / 14 ... 95 °F, <75 % RH
Power supply 3 x 1.5 V AAA batteries
Dimensions 225 x 86 x 32 mm / 8.9 x 3.4 x 1.3"
Weight ca. 330 g / 11.6 oz
   
Accuracies are given at ambient conditions of 18 ... 28 °C, 65 ... 83 °F.
*The temperature is the difference between the temperature of the operating conditions and the current ambient temperature.
 
Example:
Is the current ambient temperature greater than the temperature of the operating conditions
(50 °C/ 122°F (current ambient temperature)) - (40 °C / 104°F (operating temperature)) = 10 °C / 50°F
Is the current ambient temperature less than the temperature of the operating conditions
(0 °C / 32°F (operating temperature)) - (-5 °C / 23°F (current ambient temperature)) = 5 °C / 41°F

Delivery Scope

1 x Automotive Tester PCE-DC 20-ICA
1 x Pair of test leads
3 x 1.5V AAA batteries
1 x Transport bag
1 x User manual
1 x ISO Calibration Certificate

N.B. Calibration certificates are issued specifically for the customer and are excluded from the right of return.

Downloads