Thermo-Anemometer to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of Thermo-Anemometer is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
Data logger to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of airflow meter is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
The Class 1 IoT data logger can be used, e.g., for sound measurement of street noise, aircraft and train noise, event noise, noise coming from construction sites, ports, factories involving heavy machinery, airport/bus stations, stadiums, horse/motor racing tracks etc. The weather conditions do not matter, and hail, snow, rain and similar are no problem for this system for outdoor noise monitoring. The IoT data logger is equipped with a GPS receiver which allows the user to assign the measured values to an exact position.
- Accuracy class 1
- GPS function
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- Incl. ISO calibration certificate
The anemometer PCE-WSAC 50W 24-ICA is useful for measuring the wind speed to help determine the preferred site for a wind turbine installation. The device also monitors the wind load on existing wind farms, as well as on cranes for safey purposes. Due to the integrated 4 ... 20-mA analogue output of the anemometer, the measured data can also be transferred to other controllers for evaluation.
The anemometer PCE-WSAC 50W 230-ICA is useful for measuring the wind speed to help determine the preferred site for a wind turbine installation. The device also monitors the wind load on existing wind farms, as well as on cranes for safety purposes. Due to the integrated 4 ... 20-mA analogue output of the anemometer, the measured data can also be transferred to other controllers for evaluation.
The data logger with USB interface PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The data logger with USB interface is equipped with an octave band frequency filter. Optionally, the data logger with USB interface can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a data logger with USB interface over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate
The PCE-830 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm diameter / 2.2 in
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
The PCE-830 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
Air flow meter to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of air flow meter is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
Air velocity meter to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of air velocity meter is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
The 4-channel PCE-VM 5000 Vibration Data Logger performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration data logger is able to record vibrations at different points of the component to be tested.
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity and displacement
- Connection of up to 4 sensors simultaneously
- Data storage on SD card
- Including 2 additional sensors for vibration
- Including ISO Calibration Certificate
Wind speed meter to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of wind speed meter is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
The PCE-830-3 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
An environmental meter to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of environmental meter is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
An environmental tester to measure air temperature and velocity with calculation of volume of air current and RS-232. This kind of environmental tester is mainly for use in HVAC systems. The logging instruments are manufacturer calibrated and are delivered incl. ISO calibration certificate.
- Measurement range: 0.2 ... 20.0 m/s
- Measurement range: 0.0 ... 50.0 °C / 32 ... 122°F (sensor)
- Volumetric flow: 0 ... 36,000 m3/min
- Internal memory: 16,000 values
- Incl. ISO calibration certificate
The class 2 outdoor sound level data logger PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level data logger for measurements at workplaces, construction sites, in traffic, airports, etc.
The outdoor sound level data logger is equipped with an octave band frequency filter.
Optionally, the outdoor sound level data logger can be upgraded with a 1/3 octave band filter.
The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a sound level data logger over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate
The 4-channel PCE-VM 5000-ICA Vibration Data Logger performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested.
- 4 channels / inputs
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity, displacement
- Connection of up to 4 sensors simultaneously, 2 included
- Data storage on SD card
- Sampling rate: minimum 1 sec.
- Incl. ISO calibration certificate