The manometer PCE-PDA 01L is a reliable differential pressure gauge for pressure measurement of gases in the range of ± 200 Pa. The manometer PCE-PDA 01L has many different pressure measuring functions.
- Measuring range: ± 200 Pa / 0.029 psi / 0.002 bar
- Resolution: 0.1 Pa / 0.0000145 psi / 0.000001 bar
- Accuracy: ± 1% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
PCE-ATP 1 is a food safety / hygiene - ATP tester, ATP meter, lumitester or luminometer used for surface testing. This luminometer allows for quick and easy first-generation adenosine triphosphate (ATP) testing and monitoring to ensure proper cleanliness, sterilization and sanitization. PCE-ATP 1 is an ATP tester that can be used for cleanliness control and documentation in many different applications.
- Measurement range: 0 ... 999,999 relative light units (RLUs)
- Stores up to 10,000 date- and time-stamped data records to internal memory
- Enables rapid detection of bacterial or microbial residue
PCE-428 is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
PCE-428 is a class 2 data logging decibel meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy decibel meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The decibel meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
PCE-428 is a class 2 data logging noise meter / sound meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy noise meter / sound meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The noise meter / sound meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
PCE-428 is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
PCE-428 is a class 2 data logging SPL meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy SPL meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The SPL meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
PCE-TDS 100H is a portable handheld clamp-on ultrasonic flow meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 57 … 720 mm / approx. 2 ... 28 in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 50 … 700, 57 … 720 mm
- Sensor temperature range: 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-M1
PCE-TDS 100H-ICA is a portable handheld clamp-on ultrasonic flow meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 57 … 720 mm / approx. 2 ... 28 in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 50 … 700, 57 … 720 mm
- Sensor temperature range: 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-M1
- Incl. ISO Calibration Certificate
The PCE-360 is a Single-Phase Power Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB
(non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
- incl. ISO Calibration Certificate
The PCE-360 is a Single-Phase Power Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB
(non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
- incl. ISO Calibration Certificate
This device is a Three-Phase Power Meter / 3-Phase Power Analyzer with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB
(non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
- incl. ISO Calibration Certificate
- Handheld Particle Counter with 10 hour battery life
continuous use
- 3 channel measuring range 0.5(fixed) 0.6-25
um(user defined)
- 45,000 record internal memory
- Counting efficiency: 50% @ 0.3 μm; 100% for particles >0.45 μm per JIS
- ISO 14644-1, EU GMP Annex I, FS
209E
- Mass concentration mode (adjustable: PM 2.5, PM
10 e.g.)
- Ethernet, USB, Touch Screen display, Audible
Alarms & Wifi Optional
- Incl. calibration certificate
traceable to NIST ISO 21501-4 and JIS B9921
- Made in the USA