Wall Thickness Gauge PCE-TG 75-ICA incl. ISO Calibration Certificate
US$ 681.00
ex. VAT, ex. delivery costs
ISO Calibration
The wall thickness gauge can measure material thicknesses up to 225 mm. So that the material thickness of a wide variety of homogeneous materials can be measured, it is possible to store the corresponding sound velocity in the wall thickness gauge.

- Measuring range: 1.00 ... 225.0 mm  / 0.04 ... 8.85"
- Resolution: 0.01 mm at ≤99.99 mm
                       0.1 mm at ≥100.0 mm
- Accuracy: ±0.5% of measured value + 0.05 mm
- Memory capacity: 500 measured values
- Calibration reference on housing
- incl. ISO Calibration Certificate
Stroboscope PCE-LES 103-ICA incl. ISO-Calibration Certificate
US$ 825.00
ex. VAT, ex. delivery costs
ISO Calibration
The motion analysis of rotating machines is quick and easy with our stroboscope. The stroboscope is equipped with 3 high-power LEDs, collectively producing a light intensity of 11,730 Lux at 20 cm / 1000 Hz. With the stroboscope, you can adjust the flash frequency in both FPM and Hz. Additionally, it is compact, portable, and operates independently thanks to the built-in battery. 

Flash frequency: 60 ... 300000 FPM
Accuracy: 0.001%
- Brightness: 3 High Power LEDs
- 6160 lux at 30 cm / 1000 Hz
- Digital pulse width modulation
- Phase shift - 360° ... + 360°
- Quick adjustment with x2 and ÷2 buttons
- Intuitive control buttons
- Clear display
incl. ISO-Calibration Certificate
Manometer PCE-PDA 01L
US$ 1,156.00
ex. VAT, ex. delivery costs

The manometer PCE-PDA 01L is a reliable differential pressure gauge for pressure measurement of gases in the range of ± 200 Pa. The manometer PCE-PDA 01L has many different pressure measuring functions.


- Measuring range: ± 200 Pa  / 0.029 psi / 0.002 bar
- Resolution: 0.1 Pa / 0.0000145 psi / 0.000001 bar
- Accuracy: ± 1% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement

ATP Tester PCE-ATP 1
US$ 1,250.00
ex. VAT, ex. delivery costs

PCE-ATP 1 is a food safety / hygiene - ATP tester, ATP meter, lumitester or luminometer used for surface testing. This luminometer allows for quick and easy first-generation adenosine triphosphate (ATP) testing and monitoring to ensure proper cleanliness, sterilization and sanitization. PCE-ATP 1 is an ATP tester that can be used for cleanliness control and documentation in many different applications.


- Measurement range: 0 ... 999,999 relative light units (RLUs)
- Stores up to 10,000 date- and time-stamped data records to internal memory
- Enables rapid detection of bacterial or microbial residue

Noise Dose Meter (Badge Type) PCE-MND 10
US$ 1,313.00
ex. VAT, ex. delivery costs
The noise dose meter (badge type) was specially developed for measuring noise exposure in workplaces and complies with the IEC 61252:2002 standard. With a measuring range of 70 … 140 dB and a frequency weighting of A, B and Z, the sound dosimeter is ideal for this.

- Measuring range: 70 ... 140 dB
- Frequency weighting: A, B and Z
- Battery life: >15 hours
- LEQ measurement
- Memory
- USB interface
- Battery / power supply
- Software download
- Standards: IEC 61252:2002, ANSI S1.25-1991
Class 2 Data Logging Sound Level Meter PCE-428
US$ 1,518.00
ex. VAT, ex. delivery costs

PCE-428 is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).

- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)

ATP Tester PCE-ATP 1 KIT
US$ 1,599.00
ex. VAT, ex. delivery costs
The PCE-ATP 1-KIT is used to quickly and easily check the cleanliness of surfaces. The PCE-ATP 1 displays a measurement result on the large LC display after only 10 seconds. The PCE-ATP 1 internal memory stores up to 10,000 measured data sets with time and date.

- Measuring width: 0 ... 999,999 RLU
- Fast hygiene tests in just 10 seconds
- USB and Bluetooth printer interface
- Automatic calibration
- For HACCP implementation
- Data storage
- Enables rapid detection of bacterial or microbial residue
- Incl. 100 Test tubes (swabs)
Class 2 Data Logging Decibel Meter PCE-428-ICA incl. ISO Calibration Cert.
US$ 1,604.00
ex. VAT, ex. delivery costs
ISO Calibration

PCE-428 is a class 2 data logging decibel meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy decibel meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The decibel meter calculates the equivalent continuous sound level Leq (LXeq).

- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate

Class 2 Data Logging Noise Meter / Sound Meter PCE-428-ICA incl. ISO Cal. Cert.
US$ 1,604.00
ex. VAT, ex. delivery costs
ISO Calibration

PCE-428 is a class 2 data logging noise meter / sound meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy noise meter / sound meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The noise meter / sound meter calculates the equivalent continuous sound level Leq (LXeq).

- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate

Class 2 Data Logging Sound Level Meter PCE-428-ICA incl. ISO Calibration Cert.
US$ 1,604.00
ex. VAT, ex. delivery costs
ISO Calibration

PCE-428 is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).

- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate

Class 2 Data Logging SPL Meter PCE-428-ICA incl. ISO Calibration Cert.
US$ 1,604.00
ex. VAT, ex. delivery costs
ISO Calibration

PCE-428 is a class 2 data logging SPL meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy SPL meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The SPL meter calculates the equivalent continuous sound level Leq (LXeq).

- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate

Ultrasonic Flow Meter PCE-TDS 100H
US$ 1,841.00
ex. VAT, ex. delivery costs

PCE-TDS 100H is a portable handheld clamp-on ultrasonic flow meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 57 … 720 mm / approx. 2 ... 28 in.  Software sold separately - see accessories for details.

- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 50 … 700, 57 … 720 mm
- Sensor temperature range: 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-M1

Ultrasonic Flow Meter PCE-TDS 100H-ICA incl. ISO Calibration Certificate
US$ 2,190.00
ex. VAT, ex. delivery costs
ISO Calibration

PCE-TDS 100H-ICA is a portable handheld clamp-on ultrasonic flow meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 57 … 720 mm / approx. 2 ... 28 in.  Software sold separately - see accessories for details.

- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 50 … 700, 57 … 720 mm
- Sensor temperature range: 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-M1
- Incl. ISO Calibration Certificate

Portable Power Analyzer PCE-360
US$ 2,211.00
ex. VAT, ex. delivery costs

The PCE-360 is a Single-Phase Power Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.


- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB 
  (non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
incl. ISO Calibration Certificate 

Power Quality Analyzer PCE-360
US$ 2,211.00
ex. VAT, ex. delivery costs

The PCE-360 is a Single-Phase Power Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.


- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB 
  (non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
incl. ISO Calibration Certificate 

Three-Phase Power Meter PCE-360
US$ 2,211.00
ex. VAT, ex. delivery costs

This device is a Three-Phase Power Meter / 3-Phase Power Analyzer with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.


- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB 
  (non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
incl. ISO Calibration Certificate 

Particle Counter PCE-PQC 13US Incl. Calibration Certificate
US$ 2,895.00
ex. VAT, ex. delivery costs
The particle counter PCE-PQC 13US quickly detects where eg particles, air particles contaminate the air and can cause diseases such as asthma, bronchitis, skin and lung diseases.

- Handheld Particle Counter with 10 hour battery life continuous use
- 3 channel measuring range 0.5(fixed) 0.6-25 um(user defined)
- 45,000 record internal memory
- Counting efficiency: 50% @ 0.3 μm; 100% for particles >0.45 μm per JIS
ISO 14644-1, EU GMP Annex I, FS 209E
- Mass concentration mode (adjustablePM 2.5, PM 10 e.g.)
- Ethernet, USB, Touch Screen display, Audible Alarms & Wifi Optional
Incl. calibration certificate traceable to NIST ISO 21501-4 and JIS B9921

- Made in the USA


Ultrasonic Flow Meter PCE-TDS 100HMHS
US$ 3,069.00
ex. VAT, ex. delivery costs
The ultrasonic flow meter is required as part of a control measurement or to quickly determine the flow in a pipeline and is a portable / easy-to-install measuring system. The ultrasonic flow meter works according to the transit time difference method. The measuring principle of the flow meter is quite simple.

- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
Pipe size: DN 50 … 720 mm, DN 20 …108 mm
- Sensor temperature range: 32 ... 320°F
- Sensor installation: V, Z
- incl. sensors TDS-HM and TDS-HS on rails