The PCE-830-2 Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Analyzer also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.1 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
The PCE-830-2 Power Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.1 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
PCE-5000 is a portable hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in Non-destructive testing produces microscopic indentation.
- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available
The PCE-830 Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Analyzer also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm / 1.1 in diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 mm x 62 mm x 36 mm / 8.2 in x 2.4 in x 1.4 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
The PCE-830-3 Power Analyzer is used for measuring one to three phases of electrical quantities for alternating current (AC). This Power Analyzer also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-3007 flexible amp clamp (3000 A)
- Electrical conductor pick-up: 170 mm / 6.69 in diameter
- Length of electrical conductor: 610 mm / 24.0 in
- Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values - single phase)