The digital indicator PCE-N25Z can be used for processing different AC input signals. Depending on your specific needs, the digital indicator can be ordered with different inputs, like 100 V AC, 250 V AC, 400 V AC, 1 A AC, 5 A AC and 20...50 Hz. The input signal of the digital indicator is freely scalable, which increases its application possibilities.
- IP65 protected on the front
- 6 different inputs available
- Configuration via software
- 5-digit LED display
The digital indicator panel display PCE N24Z is used to represent AC parameters. The panel display can measure and display alternating current, AC voltage or frequency. The ability to scale the input signal is free, allowing a very wide range of applications.
- IP 65 in the front
- Measuring speed: > 0.5 sec.
- 4-digit LED screen (20 mm height)
The PCE-830-2 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This Current Clamp also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.1 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
The PCE-830-3 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This Current Clamp also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-3007 flexible amp clamp (3000 A)
- Electrical conductor pick-up: 170 mm / 6.69 in diameter
- Length of electrical conductor: 610 mm / 24.0 in
- Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values - single phase)
The PCE-830 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This Current Clamp also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm / 1.1 in diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 mm x 62 mm x 36 mm / 8.2 in x 2.4 in x 1.4 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
The PCE-830 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This Current Clamp also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.2 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
The PCE-830 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Current Clamp also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 x 62 x 36 mm
- Incl. ISO calibration certificate
The PCE-830-3 Current Clamp is used for measuring one to three phases of electrical quantities for alternating current (AC). This Current Clamp also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-3007 flexible amp clamp (3000A)
- Electrical conductor pick-up: 170 mm / 6.7 in diameter
- Minimum radial curve: 35 mm / 1.4 in
- Length of electrical conductor: 610 mm / 24 in
- Sampling rate: 2 sec.
- Memory size: 512 kB / max. 52,420 data (1 phase)
- Incl. ISO calibration certificate
The digital indicator PCE-N25T is used for processing signals coming from temperature sensors. Depending on your specific needs, the digital indicator can be ordered with different inputs for thermocouples (type J, K) or resistance thermometers (Pt100). The input signal of the digital indicator is freely scalable, which increases its application possibilities.
- IP65 protected front
- For thermocouples and resistance thermometers
- Configuration via software
- 5-digit LED display