PCE-5000 is a portable hardness tester that uses the ASTM A1038 ultrasonic contact impedance (UCI) method to measure the hardness of metals and alloys with a minimum thickness of 2 mm / .08 in. Non-destructive testing produces microscopic indentation.
- Measurement according to ASTM A1038 ultrasonic contact impedance (UCI) method
- Measurement units: Rockwell A (HRA), Rockwell B (HRB), Rockwell C (HRC), Brinell (HB), Vickers (HV) and MPa (N/mm²) SI units
- Measurement ranges: 61-85.6 HRA, 41-100 HRB, 20.3-68 HRC, 85-650 HB, 50-999 HV, 255-2180 MPa (N/mm²)
- Accuracy: ± 1.5 HR, ± 3% HB, ± 3% HV, Repeatability: ± 0.3%
- Memory size: 1,000 groups for measurement data and 20 groups for calibration data
- Different probe types (also automatic motorized probes) available
PCE-FD 20 is a portable ultrasonic thickness tester or ultrasonic thickness gauge with a large LCD screen that displays A-scan maps of ultrasonic signals as well as B-scan cross sections. Ideal for use in mechanical engineering, aerospace and metallurgical applications, this high-frequency ultrasound-based thickness meter uses a contact transducer (two different probes included; 45° and 90°) to measure material thickness and identify flaws and defects such as discontinuity in welds.
- Operating frequency range: 1 ... 10 MHz
- Measured time interval range: 6 ... 1000 microseconds (µs)
- Sound velocity: 1000 ... 9999 m/s
The UCI hardness tester PCE-3000UL can be used for quickly checking the hardness of components even after installation, two probes are included. The device offers a wide measurement range, easy handling, robust design, and a temperature resistance up to 40 °C (104 °F). Measures hardness in Rockwell, Brinell and Vickers, the UCI hardness tester can test the tensile strength of steels up to 1740 MPa or 70 HRC. The tester comes with two probes, one UCI probe for non-destructive testing and one Leeb probe for rebound testing.
- Non-destructive hardness testing
- Ultrasonic + Leeb hardness test method
- Ideal for thin metals, complex shapes, hardened layers, or requiring very small indentation
- Fast measurement times with very high accuracy
- 2 probes for UCI and Leeb rebound testing
PCE-TDS 100HSH-ICA is a portable handheld clamp-on ultrasonic flow tester used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 108 mm / approx. 3/4 in ... 4in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 15 … 700, 20 … 720 mm (approx. 3/4 … 28")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, (N,W)
- Incl. sensors TDS-M1 and TDS-S1
- Incl. ISO Calibration Certificate
PCE-TDS 100HSH is a portable handheld clamp-on ultrasonic flow test instrument or meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 108 mm / approx. 3/4 in ... 4in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 15 … 700, 20 … 720 mm (approx. 3/4 … 28")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, (N,W)
- Incl. sensors TDS-M1 and TDS-S1
PCE-TDS 100H-ICA is a portable handheld clamp-on ultrasonic flow tester used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 57 … 720 mm / approx. 2 ... 28 in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 50 … 700, 57 … 720 mm (approx. 2 … 28")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-M1
- Incl. ISO Calibration Certificate
PCE-TDS 100HS-ICA is a portable handheld clamp-on ultrasonic flow tester used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 20 … 108 mm / approx. 3/4 in ... 4in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 15 … 100, 20 … 108 mm (approx. 3/4 … 4")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, (N,W)
- Incl. sensors TDS-S1
- Incl. ISO Calibration Certificate
PCE-TDS 100H is a portable handheld clamp-on ultrasonic flow tester or meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 57 … 720 mm / approx. 2 ... 28 in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 50 … 700, 57 … 720 mm (approx. 2 … 28")
- Sensor temperature range: 0 ... 160°C / 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-M1