The Digital Multimeter is a multifunctional meter for the precise measurement of alternating and direct voltage as well as alternating and direct current that can be measured without direct contact to the line. The Digital Multimeter is suitable for measuring resistance, temperature, diodes, continuity, frequencies and capacitance and is particularly useful for diagnosing electrical and electronic components.
For maximum measurement accuracy, the Digital Multimeter supports True RMS for non-sinusoidal waveforms and a Low Impedance (LoZ) function to reduce interference. The non-contact voltage test enables reliable detection of voltages in cables and sockets.
The 2-inch LC display ensures clear readability, even under poor lighting conditions and an integrated LED torch makes it easier to work in dark environments. The device also offers automatic and manual measurement range selection, allowing it to be flexibly adapted to different measuring situations. The device also has a practical zero key which enables accurate measurement of low currents, especially when measuring direct current (DC) and ensures the compensation of deviations of the output value. Other functions include overload protection, data hold, min, max and an automatic power-off after 15 minutes to conserve battery life. The power-off can also be deactivated for longer measurements.
Compact and easy to use, the Digital Multimeter is ideal for electrical installations, maintenance work and use in automation technology. It enables safe and efficient measurements, often without direct intervention in the circuit.
| Direct voltage DC | |
| Measuring range | 0,1 ... 600 mV |
| Resolution | 0,1 mV |
| Accuracy | ±(0.5 % of Rd +5 digits) |
| Overload | 1000 V |
| Direct voltage DC | |
| Measuring range | 600 mV ... 6 V |
| Resolution | 0,001 V |
| Accuracy | ±(0.5 % of Rd +5 digits) |
| Direct voltage DC | |
| Measuring range | 6 ... 60 V |
| Resolution | 0,01 V |
| Accuracy | ±(0.5 % of Rd +5 digits) |
| Direct voltage DC | |
| Measuring range | 60 ... 600 V |
| Resolution | 0,1 V |
| Accuracy | ±(0.5 % of Rd +5 digits) |
| Direct voltage DC | |
| Measuring range | 600 ... 1000 V |
| Resolution | 1 V |
| Accuracy | ±(0.8 % of Rd +5 digits) |
| Direct current DC | |
| Measuring range | 0,1 ... 60 A |
| Resolution | 0,01 A |
| Accuracy | ±(2.5 % of Rd +8 digits) |
| Direct current DC | |
| Measuring range | 60 ... 600 A |
| Resolution | 0,01 A |
| Accuracy | ±(2.5 % of Rd +8 digits) |
| Direct current DC | |
| Measuring range | 600 ... 1000 A |
| Resolution | 0,1 A |
| Accuracy | ±(2.5 % of Rd +8 digits) |
| Capacity | |
| Measuring range | 1 ... 10 nF |
| Resolution | 0,001 nF |
| Accuracy | ±(4.0 % of Rd +5 digits) |
| Capacity | |
| Measuring range | 10 ... 100 nF |
| Resolution | 0,001 nF |
| Accuracy | ±(4.0 % of Rd +5 digits) |
| Capacity | |
| Measuring range | 100 ... 1000 nF |
| Resolution | 0,01 nF |
| Accuracy | ±(4.0 % of Rd +5 digits) |
| Capacity | |
| Measuring range | 1000 nF ... 10 µF |
| Resolution | 0,1 nF |
| Accuracy | ±(4.0 % of Rd +5 digits) |
| Capacity | |
| Measuring range | 10 ... 100 µF |
| Resolution | 0,001 µF |
| Accuracy | ±(4.0 % of Rd +5 digits) |
| Capacity | |
| Measuring range | 100 ... 1000 µF |
| Resolution | 0,01 µF |
| Accuracy | ±(4.0 % of Rd +5 digits) |
| Capacity | |
| Measuring range | 1000 µF ... 10 mF |
| Resolution | 0,1 µF |
| Accuracy | ±(4.0 % of Rd +5 digits) |
| Capacity | |
| Measuring range | 10 ... 100 mF |
| Resolution | 0,001 mF |
| Accuracy | ±(5.0 % of Rd +10 digits) |
| AC voltage | |
| Measuring range | 0,1 ... 600 mV |
| Resolution | 0,1 mV |
| Accuracy | ±(0.8 % of Rd +5 digits) |
| Overload | 750 V |
| Frequency range | 40 ... 1000 Hz |
| AC voltage | |
| Measuring range | 600 mV ... 6 V |
| Resolution | 0,1 mV |
| Accuracy | ±(0.8 % of Rd +5 digits) |
| Frequency range | 40 ... 1000 Hz |
| AC voltage | |
| Measuring range | 6 ... 60 V |
| Resolution | 0,001 V |
| Accuracy | ±(0.8 % of Rd +5 digits) |
| Frequency range | 40 ... 1000 Hz |
| AC voltage | |
| Measuring range | 60 ... 600 V |
| Resolution | 0,01 V |
| Accuracy | ±(0.8 % of Rd +5 digits) |
| Frequency range | 40 ... 1000 Hz |
| AC voltage | |
| Measuring range | 600 ... 750 V |
| Resolution | 0,1 V |
| Accuracy | ±(1.0 % of Rd +5 digits) |
| Frequency range | 40 ... 1000 Hz |
| Alternating current AC | |
| Measuring range | 0,1 ... 60 A |
| Resolution | 0,01 A |
| Accuracy | ±(2,5 % of Rd +8 digits) / VFD: ±(5.0 % of Rd +10 digits) / INRUSH: ±(5.0 % of Rd +10 digits) |
| Frequency range | 40 ... 400 Hz |
| Alternating current AC | |
| Measuring range | 60 ... 600 A |
| Resolution | 0,1 A |
| Accuracy | ±(2,5 % of Rd +8 digits) / VFD: ±(5.0 % of Rd +10 digits) / INRUSH: ±(5.0 % of Rd +10 digits) |
| Frequency range | 40 ... 400 Hz |
| Alternating current AC | |
| Measuring range | 600 ... 1000 A |
| Resolution | 1 A |
| Accuracy | ±(2,5 % of Rd +8 digits) / VFD: ±(5.0 % of Rd +10 digits) / INRUSH: ±(5.0 % of Rd +10 digits) |
| Frequency range | 40 ... 60 Hz |
| Resistance | |
| Measuring range | 0,1 ... 600 Ω |
| Resolution | 1 Ω |
| Accuracy | ±(1.0 % of Rd +5 digits) |
| Resistance | |
| Measuring range | 600 Ω ... 6 kΩ |
| Resolution | 1 Ω |
| Accuracy | ±(1.0 % of Rd +5 digits) |
| Resistance | |
| Measuring range | 6 ... 60 kΩ |
| Resolution | 0,001 kΩ |
| Accuracy | ±(1.0 % of Rd +5 digits) |
| Resistance | |
| Measuring range | 60 ... 600 kΩ |
| Resolution | 0,01 kΩ |
| Accuracy | ±(1.0 % of Rd +5 digits) |
| Resistance | |
| Measuring range | 600 kΩ ... 6 M Ω |
| Resolution | 0,1 kΩ |
| Accuracy | ±(1.0 % of Rd +5 digits) |
| Resistance | |
| Measuring range | 6 ... 60 M Ω |
| Resolution | 0,001 M Ω |
| Accuracy | ±(1.0 % of Rd +5 digits) |
| Frequency | |
| Measuring range | 0 ... 10 Hz |
| Resolution | 0,001 Hz |
| Accuracy | ±(1.0 % of Rd +3 digits) |
| Frequency | |
| Measuring range | 10 ... 100 Hz |
| Resolution | 0,001 Hz |
| Accuracy | ±(1.0 % of Rd +3 digits) |
| Frequency | |
| Measuring range | 100 ... 1000 Hz |
| Resolution | 0,01 Hz |
| Accuracy | ±(1.0 % of Rd +3 digits) |
| Frequency | |
| Measuring range | 1000 Hz ... 10 kHz |
| Resolution | 0,1 Hz |
| Accuracy | ±(1.0 % of Rd +3 digits) |
| Frequency | |
| Measuring range | 10 ... 100 kHz |
| Resolution | 0,001 kHz |
| Accuracy | ±(1.0 % of Rd +3 digits) |
| Frequency | |
| Measuring range | 100 ... 1000 kHz |
| Resolution | 0,01 kHz |
| Accuracy | ±(1,0 % v.Mw. +3 Digits) |
| Frequency | |
| Measuring range | 1000 kHz ... 10 MHz |
| Resolution | 0,1 kHz |
| Accuracy | ±(3.0% v.Mw. +3 Digits) |
| Temperature | |
| Measuring range | -20 ... 0 °C |
| Resolution | 0,1 °C |
| Accuracy | ±3°C |
| Temperature | |
| Measuring range | 0 ... 400 °C |
| Resolution | 0,1 °C |
| Accuracy | ±1.0 % or ±2 °C |
| Temperature | |
| Measuring range | 400 ... 1000 °C |
| Resolution | 0,1 °C |
| Accuracy | ±2.0 % |
| Temperature | |
| Measuring range | -4 ... +32 °F |
| Resolution | 1 °F |
| Accuracy | ±6 °F |
| Temperature | |
| Measuring range | 32 ... 752 °F |
| Resolution | 1 °F |
| Accuracy | ±1.0 % or ±4 °F |
| Temperature | |
| Measuring range | 752 ... 1832 °F |
| Resolution | 1 °F |
| Accuracy | ±2.0 % |
| General technical data | |
| Measuring functions | MIN, MAX, HOLD |
| Display type | LCD |
| Display size | 2 in |
| Standard(s) | IEC61010-1, IEC 61010-2-032, IEC 61010-2-033 |
| Maximum cable diameter | 35 mm |
| Automatic power-off | 15 min |
| Safety standard | CAT III 1000V, CAT IV 600V |
| max. input impedance | 10 M Ω |
| Measuring range selection | Automatic, Manual |
| Diode test | Test current: approx. 1.5 mA Test voltage: approx. 1 V Overload protection: 250 V |
| Display range | 6000 counts |
| Protection class (device) | IP20 |
| (Rechargeable) battery | 3 x 1,5 V AAA battery , Alkali-manganese |
| Capacity | 1200 mAh |
| Operating conditions | 0 ... 40 °C , 0 ... 80 % RH |
| Storage conditions | -10 ... 60 °C , 0 ... 70 % RH |
| Dimensions ( L x W x H ) | 240 x 85 x 45 mm |
| Weight | 327 g |