The closing force measuring device is a wireless, electronic measuring device for externally powered doors and gates. Typical use is the final inspection of new systems as well as regular inspections.
A further development of the well-established FM 100 closing force measuring device is supplied with the closing force measuring device. It combines the well-known robust construction for years of use in harsh environments and lasting precision with the flexibility of a wireless application and a user-friendly app.
This results in many advantages for you in daily use, such as automatic measuring point identification via QR and barcodes, the immediate availability of the measured values and the direct creation of a PDF report.
| Force | |
| Measuring range | 0 ... 2000 N |
| Resolution | 1 N |
| Accuracy | ±3 N or 3 % of Rd |
| General technical data | |
| Interface | Micro-USB, Bluetooth |
| Standard(s) | EN 14752:2015 |
| Standard(s) additional information | - EN 81-1 2000-4-EG - FMVSS118 - APTA PR-M-S-18-10 - ASME A17.1 2000 - DIN EN 14752:2005 - 2001-85-EG / ECE R. 107 §35 e (5) StVZO (German Road Traffic Licensing Regulations) - EN14120 DIN 18650-1 - DIN EN 12453 - DIN EN 16005 - DIN EN 60335-2-103 - ASR A1.7 - ECE R-21 - prEN 12650-1 |
| Stiffness | 500 N/mm |
| Gap width | 50 mm |
| Menu language | English, German |
| Protection class (device) | IP43 |
| Power supply | 3.7V / 700 mAh |
| Connector type | Euro plug |
| (Rechargeable) battery | 1 x 3,7 V LP series , Lithium-ion polymer battery |
| Capacity | 700 mAh |
| Performance | 2,59 Wh |
| Operating conditions | -10 ... 50 °C , 0 ... 90 % RH |
| Storage conditions | -40 ... 50 °C , 0 ... 90 % RH |
| Dimensions ( L x W x H x ø ) | 210 x 80 x 50 x 80 mm |
| Weight | 2100 g |