Zum Hauptinhalt springen
Automotive Tester LM-MCDX-1FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Automotive Tester. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Automotive Tester allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 1000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 px)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for small indoor spaces
Automotive Tester LM-MCDX-6FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Automotive Tester. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Automotive Tester allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 6000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for interiors and pipes
Car Measuring Device LM-MCDX-1FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Car Measuring Device. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Car Measuring Device allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 1000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 px)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for small indoor spaces
Car Measuring Device LM-MCDX-6FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Car Measuring Device. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Car Measuring Device allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 6000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for interiors and pipes
Coating Thickness Gauge LM-MCDX-1FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Coating Thickness Gauge. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Coating Thickness Gauge allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 1000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 px)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for small indoor spaces
Coating Thickness Gauge LM-MCDX-6FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Coating Thickness Gauge. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Coating Thickness Gauge allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 6000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for interiors and pipes
Material Tester LM-MCDX-1FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Material Tester. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Material Tester allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 1000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 px)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for small indoor spaces
Material Tester LM-MCDX-6FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Material Tester. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Material Tester allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 6000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for interiors and pipes
Material Thickness Meter LM-MCDX-1FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Material Thickness Meter. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Material Thickness Meter allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 1000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 px)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for small indoor spaces
Material Thickness Meter LM-MCDX-6FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Material Thickness Meter. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Material Thickness Meter allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 6000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for interiors and pipes
Paint Gauge / Paint Tester LM-MCDX-1FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Paint Gauge / Paint Tester. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Paint Gauge / Paint Tester allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 1000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 px)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for small indoor spaces
Paint Gauge / Paint Tester LM-MCDX-6FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Paint Gauge / Paint Tester. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Paint Gauge / Paint Tester allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 6000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for interiors and pipes
Paint Test Equipment / Paint Testing Equipment LM-MCDX-1FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Paint Test Equipment / Paint Testing Equipment. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Paint Test Equipment / Paint Testing Equipment allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 1000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 px)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for small indoor spaces
Paint Test Equipment / Paint Testing Equipment LM-MCDX-6FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Paint Test Equipment / Paint Testing Equipment. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Paint Test Equipment / Paint Testing Equipment allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 6000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for interiors and pipes
Surface Testing LM-MCDX-1FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Surface Testing. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Surface Testing allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 1000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 px)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for small indoor spaces
Surface Testing LM-MCDX-6FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Surface Testing. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Surface Testing allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 6000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for interiors and pipes
Thickness Gauge LM-MCDX-1FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Thickness Gauge. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Thickness Gauge allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 1000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 px)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for small indoor spaces
Thickness Gauge LM-MCDX-6FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Thickness Gauge. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Thickness Gauge allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 6000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for interiors and pipes
Thickness Meter LM-MCDX-1FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Thickness Meter. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Thickness Meter allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 1000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 px)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for small indoor spaces
Thickness Meter LM-MCDX-6FT
1.300,00 €
Price excl. VAT &. delivery
Numerous specialized digital probes can be connected to the Thickness Meter. This makes applications on particularly small openings, thick coatings and hard-to-reach or small measuring points possible without any problems. The magnetic induction method for this Thickness Meter allows measurements of paint, varnish, plastic, rubber, ceramics, galvanized coatings and galvanic coatings on steel. The eddy current method can be used to measure insulating layers such as paint, varnish, plastic or anodized coatings on non-ferrous metals.

  • Layer thickness: 2 ... 6000 µm
  • smallest resolution: 0.1 µm
  • Accuracy: ±1 % (100 ... 1000 µm)
  • Single measurement, scan measurement, duplex measurement
  • Color touch screen (320 × 480 pixels)
  • Data storage
  • USB and wireless
  • Rod-shaped transversal probe for interiors and pipes
Class 2 Data Logging Decibel Meter PCE-428-ICA incl. ISO Calibration Cert.
1.299,90 €
Price excl. VAT &. delivery
ISO Calibration

PCE-428 is a class 2 data logging decibel meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy decibel meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The decibel meter calculates the equivalent continuous sound level Leq (LXeq).

  • Measuring range: 25 … 136 db(A)
  • LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
  • Frequency weighting: A, B, C and Z
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)
  • incl. ISO Calibration Certificate

Class 2 Data Logging Noise Meter / Sound Meter PCE-428-ICA incl. ISO Cal. Cert.
1.299,90 €
Price excl. VAT &. delivery
ISO Calibration

PCE-428 is a class 2 data logging noise meter / sound meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy noise meter / sound meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The noise meter / sound meter calculates the equivalent continuous sound level Leq (LXeq).

  • Measuring range: 25 … 136 db(A)
  • LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
  • Frequency weighting: A, B, C and Z
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)
  • incl. ISO Calibration Certificate

Class 2 Data Logging Sound Level Meter PCE-428-ICA incl. ISO Calibration Cert.
1.299,90 €
Price excl. VAT &. delivery
ISO Calibration

PCE-428 is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).

  • Measuring range: 25 … 136 db(A)
  • LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
  • Frequency weighting: A, B, C and Z
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)
  • incl. ISO Calibration Certificate

Class 2 Data Logging SPL Meter PCE-428-ICA incl. ISO Calibration Cert.
1.299,90 €
Price excl. VAT &. delivery
ISO Calibration

PCE-428 is a class 2 data logging SPL meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy SPL meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The SPL meter calculates the equivalent continuous sound level Leq (LXeq).

  • Measuring range: 25 … 136 db(A)
  • LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
  • Frequency weighting: A, B, C and Z
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)
  • incl. ISO Calibration Certificate

Condition Monitoring Sound Level Meter PCE-428-ICA incl. ISO Calibration Cert.
1.299,90 €
Price excl. VAT &. delivery
ISO Calibration

The Condition Monitoring Sound Level Meter is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy Condition Monitoring Sound Level Meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The Condition Monitoring Sound Level Meter calculates the equivalent continuous sound level Leq (LXeq).

  • Measuring range: 25 … 136 db(A)
  • LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
  • Frequency weighting: A, B, C and Z
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)
  • incl. ISO Calibration Certificate

 

Data Logger with USB Interface PCE-428-ICA incl. ISO Calibration Certificate
1.299,90 €
Price excl. VAT &. delivery
ISO Calibration

The data logger with USB interface is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy data logger with USB interface has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).

  • Measuring range: 25 … 136 db(A)
  • LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
  • Frequency weighting: A, B, C and Z
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)
  • incl. ISO Calibration Certificate

Electromagnetic Field Meter PCE-PSM 10
1.299,90 €
Price excl. VAT &. delivery
The Electromagnetic Field Meter has a measurement range of 0.1 to 200 kV and an accuracy of ±10 % and is a test device for detecting the electrostatic voltage on the surface of objects. It uses non-contact measurement technology to detect the electrostatic field. In addition, the Electromagnetic Field Meter has an earth connection to ensure proper earthing and therefore safety during use.

  • static charge: 0.1 ... 200 kV
  • resolution: 0.1 kV DC
  • accuracy: ±10 %
  • measuring function: hold
  • earth connection
EMF measuring device PCE-PSM 10
1.299,90 €
Price excl. VAT &. delivery
The EMF measuring device has a measurement range of 0.1 to 200 kV and an accuracy of ±10 % and is a test device for detecting the electrostatic voltage on the surface of objects. It uses non-contact measurement technology to detect the electrostatic field. In addition, the EMF measuring device has an earth connection to ensure proper earthing and therefore safety during use.

  • static charge: 0.1 ... 200 kV
  • resolution: 0.1 kV DC
  • accuracy: ±10 %
  • measuring function: hold
  • earth connection
Environmental Meter PCE-428-ICA incl. ISO Calibration Certificate
1.299,90 €
Price excl. VAT &. delivery
ISO Calibration

The environmental meter is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy environmental meter has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).

  • Measuring range: 25 … 136 db(A)
  • LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
  • Frequency weighting: A, B, C and Z
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)
  • incl. ISO Calibration Certificate

Environmental Tester PCE-428-ICA incl. ISO Calibration Certificate
1.299,90 €
Price excl. VAT &. delivery
ISO Calibration

The environmental tester is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy environmental tester has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).

  • Measuring range: 25 … 136 db(A)
  • LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
  • Frequency weighting: A, B, C and Z
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)
  • incl. ISO Calibration Certificate

Health & Safety PCE-PSM 10
1.299,90 €
Price excl. VAT &. delivery
The Health & Safety has a measurement range of 0.1 to 200 kV and an accuracy of ±10 % and is a test device for detecting the electrostatic voltage on the surface of objects. It uses non-contact measurement technology to detect the electrostatic field. In addition, the Health & Safety has an earth connection to ensure proper earthing and therefore safety during use.

  • static charge: 0.1 ... 200 kV
  • resolution: 0.1 kV DC
  • accuracy: ±10 %
  • measuring function: hold
  • earth connection
Radiation Detector PCE-PSM 10
1.299,90 €
Price excl. VAT &. delivery
The Radiation Detector has a measurement range of 0.1 to 200 kV and an accuracy of ±10 % and is a test device for detecting the electrostatic voltage on the surface of objects. It uses non-contact measurement technology to detect the electrostatic field. In addition, the Radiation Detector has an earth connection to ensure proper earthing and therefore safety during use.

  • static charge: 0.1 ... 200 kV
  • resolution: 0.1 kV DC
  • accuracy: ±10 %
  • measuring function: hold
  • earth connection
Radioactivity Meter PCE-PSM 10
1.299,90 €
Price excl. VAT &. delivery
The Radioactivity Meter has a measurement range of 0.1 to 200 kV and an accuracy of ±10 % and is a test device for detecting the electrostatic voltage on the surface of objects. It uses non-contact measurement technology to detect the electrostatic field. In addition, the Radioactivity Meter has an earth connection to ensure proper earthing and therefore safety during use.

  • static charge: 0.1 ... 200 kV
  • resolution: 0.1 kV DC
  • accuracy: ±10 %
  • measuring function: hold
  • earth connection
Sound Level Data Logger PCE-428-ICA incl. ISO Calibration Cert.
1.299,90 €
Price excl. VAT &. delivery
ISO Calibration

PCE-428 is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level data logger has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).

  • Measuring range: 25 … 136 db(A)
  • LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
  • Frequency weighting: A, B, C and Z
  • Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
  • adjustable data-recording interval from 1 s … 24 h
  • 1/1 octave band filter (optional 1/3 octave band filter upgrade)
  • incl. ISO Calibration Certificate

Class 2 Data Logging Decibel Meter PCE-428-Kit-N with Sound Calibrator
1.298,90 €
Price excl. VAT &. delivery

The data logging decibel meter is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The decibel meter is a class 2 device and is equipped with an octave band frequency filter. The decibel meter can optionally be upgraded with a 1/3 octave band filter.

  • Accuracy class 2
  • A, B, C & Z frequency weighting
  • Fast, Slow, Impulse and Peak time weighting
  • Statistics function
  • 1/1 octave band included
  • 1/3 octave band optional
  • Including class II sound calibrator

Class 2 Data Logging Noise Meter / Sound Meter PCE-428-Kit-N & Sound Calibrator
1.298,90 €
Price excl. VAT &. delivery

The data logging noise meter / sound meter is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The noise meter / sound meter is a class 2 device and is equipped with an octave band frequency filter. The noise meter / sound meter can optionally be upgraded with a 1/3 octave band filter.

  • Accuracy class 2
  • A, B, C & Z frequency weighting
  • Fast, Slow, Impulse and Peak time weighting
  • Statistics function
  • 1/1 octave band included
  • 1/3 octave band optional
  • Including class II sound calibrator