Sound Level Data Logger PCE-322ALEQ-ICA incl. ISO Calibration Certificate
545,90 €
Price excl. VAT &. delivery
ISO Calibration
The sound level data logger PCE-322A is particularly suitable for measuring noise in the field of industrial, health, safety and environmental monitoring. The PCE-322A sound level data logger has a logger function, which allows storage of up to 32700 readings.


  • Automatic range: 30 … 130 dB
  • Manual range: 30 … 80 / 50 … 100 / 80 … 130 dB
  • Resolution: 0.1 dB
  • Accuracy: ±1.4 dB
  • Memory capacity: 32700 values
  • incl. software for LEQ calculation
  • incl. ISO calibration certificate Important! The LEQ value is only calculated by the software after the data transfer from the device to the PC or laptop.

Hygiene Tester PCE-ATP 1 KIT3 for surfaces and water
1.859,90 €
Price excl. VAT &. delivery
The PCE-ATP 1-KIT3 is used to quickly and easily check the cleanliness of surfaces and water. The  ATP Testing Meter displays a measurement result on the large LC display after only 10 seconds. Up to 10,000 measurement data sets with time and date can be stored on the internal memory of the ATP measuring device.

  • Measuring width: 0 … 999,999 RLU
  • Fast hygiene tests in just 10 seconds
  • USB and Bluetooth printer interface
  • Automatic calibration
  • For HACCP implementation
  • Data storage
  • Incl. 100 Test tubes (swabs) for surfaces
  • Incl. 100 Test tubes (swabs) for water
Particle Counter PCE-PQC 35EU Incl. Calibration Certificate
8.359,90 €
Price excl. VAT &. delivery
ISO Calibration
The environmental particle counter PCE-PQC 35EU is characterized by its small size and easy wall mounting. The fixed installation of the environmental particle counter ensures high-precision air quality studies.

  • Measuring range: 0.3 … 25 μm
  • Measurement channel sizes: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm
  • Counting efficiency: 50% at 0.3 μm, 100% at > 0.45 μm according to JIS
  • CO2 Sensor: 0 … 5000 ppm
  • PID Sensor: 0 … 50 ppm
  • Ethernet, USB
  • Includes temperature and humidity sensor
  • Incl. calibration certificate traceable to NIST ISO 21501-4 and JIS B9921
HVAC Meter PCE-VE 900N4 1.2 m / 4-way-head / Ø 2 mm
11.749,90 €
Price excl. VAT &. delivery

The HVAC meter has a 1.2 m / 3.9 ft long endoscope cable. With a diameter of only 2 mm, cavities with the smallest access can be viewed with the help of this HVAC meter. The camera head of this HVAC meter can move freely in 4 directions.

  • Cable / head diameter: 2 mm
  • Direction of movement camera head: 4-way
  • Camera head length: 7 mm
  • Bending radius: 6 mm
  • 1.2 m / 3.9 ft endoscope cable
  • 5" monitor
  • Image and video memory
  • IP58 camera cable
  • 400 x 400 pixel image resolution

Air Quality Meter PCE-AQD 20-ICA Incl. ISO Calibration Certificate
859,90 €
Price excl. VAT &. delivery
ISO Calibration
The air quality meter is an ideal measuring device for monitoring the air quality at workplaces. The health and environmental air quality meter is ideal for continuous logging of air temperature, humidity, CO2, PM2.5 and air pressure.

Measuring function
  • PM2.5
  • Humidity
  • Temperature
  • CO2
  • Air pressure
  • Memory: SD card max. 32 GB
  • Ideal for workplace monitoring
  • Alarm function
  • Incl. ISO calibration certificate
HVAC Meter 2-Channel PCE-PA 7500-ICA incl. ISO-Calibration Certificate
1.586,90 €
Price excl. VAT &. delivery
ISO Calibration
The HVAC meter is used for the quick and precise measurement or analysis of parameters such as power consumption and quality. The power meter has 2 input channels for measuring parameters including voltage, current, active power, power factor, frequency, and energy consumption in kWh.

  • Power range: 0.1 … 5000 W
  • Current range: 0.001 … 20 A AC
  • Frequency, power factor, energy
  • Accuracy: ±(0.4% of reading + 0.1)
  • 2 input channels
  • Color display
  • incl. ISO-Calibration Certificate
Data Logging Sound Level Meter PCE-322ALEQ
452,90 €
Price excl. VAT &. delivery
Topseller
The data logging sound level meter PCE-322ALEQ is particularly suitable for measuring noise in the field of industrial, health, safety and environmental monitoring. The PCE-322ALEQ data logging sound level meter / noise level meter has a logger function, which allows storage of up to 32700 readings.


  • Automatic range: 30 … 130 dB
  • Manual range: 30 … 80 / 50 … 100 / 80 … 130 dB
  • Resolution: 0.1 dB
  • Accuracy: ±1.4 dB
  • Memory capacity: 32700 values
  • incl. software for LEQ calculationImportant! The LEQ value is only calculated by the software after the data transfer from the device to the PC or laptop.

HVAC meter PCE-PA 8500-ICA incl. ISO-Calibration Certificate
3.714,90 €
Price excl. VAT &. delivery
ISO Calibration
The HVAC meter redefines standards in electrical measurement technology, offering a comprehensive range of features for precise and detailed measurements. The HVAC meter allows accurate measurements of electrical voltage, current, frequency, harmonics, and starting currents. In addition, precise power and energy measurements can be performed, enabling accurate monitoring and optimization of energy consumption.

  • Voltages: 1 … 1000 V
  • Current: 15 … 3000 A AC
  • Graphical representation of waveform and vector graphics
  • Data logger with 8 GB storage
  • LAN and USB data interface
  • Includes flexible current clamps
  • Compliance with standards: IEC61000-4-30, 61000-4-15, 
      61000-4-7, EN50160
  • incl. ISO-Calibration Certificate
HVAC Meter PCE-PA 8500 HP
3.283,90 €
Price excl. VAT &. delivery
Topseller
The HVAC meter redefines the standards in electrical measurement technology and offers a comprehensive range of functions for precise and detailed measurements. The HVAC meter enables accurate measurements of electrical voltage, current, frequency, harmonics, harmonic and starting currents. In addition, precise power and energy measurements can be made, enabling accurate monitoring and optimisation of energy consumption.

  • Voltages: 1 … 1000 V
  • Current: 1 … 1500 A AC
  • Graphical representation of the
      waveform and vector graphics
  • Data logger with 8 GB memory
  • LAN and USB data interface
  • incl. flexible current clamps
  • Test standards:
    IEC61000-4-30, 61000-4-15, 61000-4-7, EN50160