2 year Warranty
PCE-WMM 50-ICA is a wall-mounted carbon dioxide meter that uses diffusion to monitor carbon dioxide (CO2) gas levels and ambient temperature (ºC / ºF) indoors. This indoor carbon dioxide meter features an alarm-activated potential-free contact that can, for example, activate a fan to reduce CO2 gas concentration in the room.
- CO2 gas measurement range: 0 ... 50,000 ppm
- Temperature measurement range: 0 ... +45 ºC / +32 ... +113 ºF
- IP54-rated enclosure on sensor and remote display units
- 2 adjustable alarm thresholds
- 3- to 4-digit remote display (depends on range)
- incl. ISO Calibration Certificate
PCE-WMM 50-ICA is a wall-mounted CO2 analyzer that uses diffusion to monitor carbon dioxide (CO2) gas levels and ambient temperature (ºC / ºF) indoors. This indoor CO2 analyzer features an alarm-activated potential-free contact that can, for example, activate a fan to reduce CO2 gas concentration in the room.
- CO2 gas measurement range: 0 ... 50,000 ppm
- Temperature measurement range: 0 ... +45 ºC / +32 ... +113 ºF
- IP54-rated enclosure on sensor and remote display units
- 2 adjustable alarm thresholds
- 3- to 4-digit remote display (depends on range)
- incl. ISO Calibration Certificate
The HVACR Tester is used for measuring one to three phases of electrical quantities for alternating current (AC). This HVACR Tester also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.2 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 x 97 x 46 mm / 9.6 x 3.8 x 1.8 in
- Incl. ISO calibration certificate
The HVAC meter is a portable handheld Clamp Meter used for the testing and inspection of 3-phase / 4-wire, 3-phase / 3-wire, 1-phase / 2-wire and 1-phase / 3-wire electrical circuits. This handy HVAC meter not only measures multiple electrical properties in real time, but also saves the measurement data in .xls format to the included SD card memory for quick and easy data transfer and analysis using Microsoft Excel.
- True RMS measurement for ACA, ACV
- True power: W, KW, MW
- VA, KVA, MVA, VAR, KVAR, MVAR
- PF (power factor), phase angle (Φ)
- KWH, KVAH, KVARH, PFH
- Voltage measurement range: 10 ... 600 ACV
- Current measurement range: 0.2 ... 1200 ACA
- Real-time current, voltage and power consumption measurement
- Built-in data recorder with adjustable sample rate: 2 ... 7,200 sec.
- Incl. ISO Calibration Certificate
PCE-WMM 50 is a wall-mounted gas detector that uses diffusion to monitor carbon dioxide (CO2) gas levels and ambient temperature (ºC / ºF) indoors. This indoor air quality meter features an alarm-activated potential-free contact that can, for example, activate a fan to reduce CO2 gas concentration in the room.
- CO2 gas measurement range: 0 ... 50,000 ppm
- Temperature measurement range: 0 ... +45 ºC / +32 ... +113 ºF
- IP54-rated enclosure on sensor and remote display units
- 2 adjustable alarm thresholds
- 3- to 4-digit remote display (depends on range)
The PCE-PCO 1 is a handheld laser dust monitor, or dust measuring device, for measuring the concentration of particles in the air. The dust monitor:
- Measures 6 sizes of particles: 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm
- Offers a robust 80 MB internal memory and microSD card slot
- Features a large, full-color LCD display with backlight
- Includes a built-in camera for image and video recording
- Contains sensors for measuring air temperature, dew point and relative humidity
- Displays temperature in degrees Celsius (°C) or Fahrenheit (°F)
PCE-RCM 10 is a portable handheld dust particle measuring device or particle counter used to monitor particulate matter (PM) concentrations in the air. Designed to aid in indoor air quality (IAQ) assessments, this particle counter also measures air temperature and relative humidity (RH).
- PM channels: PM 2.5, PM 10
- Particle sizes (in micrometers): 2.5 µm, 10 µm
- Temp. measuring range: -20 ... +70 °C / -4 ... +158 °F
- Humidity measuring range: 0 ... 100 % RH
- 2.4" full-color LCD with user-friendly graphics
- For indicative measurements
PCE-RCM 10 is a portable handheld environmental tester or particle counter used to monitor particulate matter (PM) concentrations in the air. Designed to aid in indoor air quality (IAQ) assessments, this environmental tester also measures air temperature and relative humidity (RH).
- PM channels: PM 2.5, PM 10
- Particle sizes (in micrometers): 2.5 µm, 10 µm
- Temp. measuring range: -20 ... +70 °C / -4 ... +158 °F
- Humidity measuring range: 0 ... 100 % RH
- 2.4" full-color LCD with user-friendly graphics
- For indicative measurements
PCE-PCO 1 is a handheld particle-counting air quality meter or dust measuring device for measuring the concentration of particles in the air. The PCE-PCO 1 hygienic dust measuring device:
- Measures 6 sizes of particles: 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm
- Offers a robust, 80 MB internal memory
- Features a large, full-color LCD display with backlight
- Includes a built-in camera for image and video recording
- Contains sensors for measuring air temperature, dew point and relative
humidity
- Displays temperature in degrees Celsius (°C) or Fahrenheit (°F)
PCE-PCO 1 is an airborne particle-counting hygiene meter or dust measuring device for measuring the concentration of particles in the air. The PCE-PCO 1 handheld particle counter:
- Measures 6 sizes of particles: 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm
- Offers a robust, 80 MB internal memory
- Features a large, full-color LCD display with backlight
- Includes a built-in camera for image and video recording
- Contains sensors for measuring air temperature, dew point and relative
humidity
- Displays temperature in degrees Celsius (°C) or Fahrenheit (°F)
PCE-PCO 1 is a handheld laser optical particle counter, or dust particle measuring device, for measuring the concentration of particles in the air. The dust particle measuring device:
- Measures 6 sizes of particles: 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm, 10 µm
- Offers a robust 80 MB internal memory and microSD card slot
- Features a large, full-color LCD display with backlight
- Includes a built-in camera for image and video recording
- Contains sensors for measuring air temperature, dew point and relative
humidity
- Displays temperature in degrees Celsius (°C) or Fahrenheit (°F)
PCE-WMM 50 is a wall-mounted air quality meter that uses diffusion to monitor carbon dioxide (CO2) gas levels and ambient temperature (ºC / ºF) indoors. This indoor air quality meter features an alarm-activated potential-free contact that can, for example, activate a fan to reduce CO2 gas concentration in the room.
- CO2 gas measurement range: 0... 50,000 ppm
- Temperature measurement range: 0... +45 ºC / +32... +113 ºF
- IP54-rated enclosure on sensor and remote display units
- 2 adjustable alarm thresholds
- 3- to 4-digit remote display (depends on range)
The PCE-830 HVAC Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This HVAC Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm / 1.1 in diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 mm x 62 mm x 36 mm / 8.2 in x 2.4 in x 1.4 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
The PCE-830-3 HVAC Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This HVAC Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-3007 flexible amp clamp (3000 A)
- Electrical conductor pick-up: 170 mm / 6.69 in diameter
- Length of electrical conductor: 610 mm / 24.0 in
- Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values - single phase)
This hygrometer kit includes gauges for demanding applications with advanced functionality. The hygrometer kit has been specially formulated to meet all requirements with regard to the assessment of the environment. With these devices, the recorded values are saved and can then be evaluated on a PC or laptop. The hygrometer kit consists of the following devices:
- P1 / PCE-322A
- P2 / PCE-890U
- P3 / PCE-174
- P4 / PCE-330