PCE Instruments: Test Instruments

Order no.: CA-Y3N

The Y-Series Clamp on Tester Adapter is designed to be used with multimeters or oscilloscopes and can measure up to 600 A, with a maximum enclosure diameter of 30 mm (1.2 in). his universally applicable Clamp on Tester Adapter does not need its own power supply, just connect the instrument with the test leads to the meter, removing the need to worry about the battery charge. The Clamp on Tester Adapter comes manufacturer calibrated.
- Measuring range: 4 A ... 600 A AC
- Accuracy: 3%
- Transformer ratio (E:A): 100 : 1

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-Y4N

The Y-Series Clamp on Tester Adapter is designed to be used with multimeters or oscilloscopes and can measure up to 600 A, with a maximum enclosure diameter of 30 mm (1.2 in). his universally applicable Clamp on Tester Adapter does not need its own power supply, just connect the instrument with the test leads to the meter, removing the need to worry about the battery charge. The Clamp on Tester Adapter comes manufacturer calibrated.
- Measuring range: 4 A ... 600 A AC
- Accuracy: 2%
- Transformer ratio (E:A): 1 A : 1 mV DC

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-Y7N

The Y-Series Clamp on Tester Adapter is designed to be used with multimeters or oscilloscopes and can measure up to 600 A, with a maximum enclosure diameter of 30 mm (1.2 in). his universally applicable Clamp on Tester Adapter does not need its own power supply, just connect the instrument with the test leads to the meter, removing the need to worry about the battery charge. The Clamp on Tester Adapter comes manufacturer calibrated.
- Measuring range: 1 A ... 500 A AC
- Accuracy: ≤2%
- Transformer ratio (E:A): 1 A : 1 mV AC

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-A100-504

The AmpFLEX CA-A100-504 series Clamp on Tester measures the current according to the Rogowski principle. This Flex Clamp on Tester can safely measure the current contactless up to 2000 A. The flexible current probe can be connected to, for example, a multimeter via 4 mm (1.6 in) safety plugs. The Flex Clamp on Tester can be up to 45 cm (1.6 in) in length and can be easily set to busbars or large cable bundles.
- Range: 0.2 kA - 2 kA
- Accuracy: 1 %
- Loop length: 45 cm / 17.7 in

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-B102

The CA-B102 Clamp on Tester is designed for fast location of insulation faults. The Clamp on Tester has a maximum diameter up to 112 mm (4.4 in), and can be used with multimeters. Two selectable measuring ranges are available to allow for precise measurement according to DIN VDE 010.
- Dual range: 4 A and 400 A AC
- Large jaw diameter: 112 mm / 4.4 in
- For measurement according to DIN VDE 0100

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C100

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 0.1 A ... 1000 A
- Transformer Ratio: 1000 / 1
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-C102

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 0.1 A ... 1000 A
- Transformer Ratio: 1000 / 1
- Connection: 4 mm / 0.2 in socket
- Output protected against voltage surges

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-C103

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 0.1 A ... 1000 A
- Transformer Ratio: 1000 / 1
- Connection: 4 mm / 0.2 in male plugs

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-C106

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 0.1 A ... 1000 A
- Transformer Ratio: 1000 / 1
- Connection: 4 mm / 0.2 in socket
- Output: AC voltage

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-C107

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 0.1 A ... 1000 A
- Transformer Ratio: 1000 / 1
- Connection: 4 mm / 0.2 in plug
- Output: AC voltage

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-C112

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 10 mA ... 1000 A
- Transformer Ratio: 1000 / 1
- Connection: 4 mm / 0.2 in sockets

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-C113

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 10 mA ... 1000 A
- Transformer Ratio: 1000 / 1
- Connection: 4 mm / 0.2 in plug

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-C122

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 1 A ... 1000 A
- Transformer Ratio: 1000 / 5
- Connection: 4 mm / 0.2 in sockets

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-C160

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 100 mA ... 10 A, 100 mA ... 100 A, 1 A ... 1000 A
- Input / Output: 100 mV / 1 A, 10 mV / 1 A, 1 mV / 1 A
- Connection: 4 mm / 0.2 in BNC connector for oscilloscopes
- Output: AC voltage

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-D30CN

The CA-D30CN D Series Clamp on Tester for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Clamp on Tester is particularly suitable for busbars and cables with a large cross section. The Clamp on Tester adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 3000 A
- Transformer Ratio: 3 A / 1 mA
- Connection: cable with plug

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-D30N

The CA-D30N D Series Clamp on Tester for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Clamp on Tester is particularly suitable for busbars and cables with a large cross section.
- Measuring range: 1 A to 3000 A
- Transformer Ratio: 3 A / 1 mA
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-D31N

The CA-D31N D Series Clamp on Tester for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Clamp on Tester is particularly suitable for busbars and cables with a large cross section. The Clamp on Tester adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 500 A, 1 A to 1000 A, 1 A to 1500 A
- Transformer Ratio: 0.5 A / 1 mA, 1 A / 1 mA, 1.5 A / 1 mA
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-D32N

The CA-D32N D Series Clamp on Tester for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Clamp on Tester is particularly suitable for busbars and cables with a large cross section. The Clamp on Tester adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 1000 A, 1 A to 2000 A, 1 A to 3000 A
- Transformer Ratio: 1 A / 1 mA, 2 A / 1 mA, 3 A / 1 mA
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-D33N

The CA-D33N D Series Clamp on Tester for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows for accurate AC current measurement even at currents up to 3000 A. Due to the rectangular shape, the D Series is particularly suitable for busbars and cables with a large cross section. The Clamp on Tester adapter comes manufacturer calibrated with ISO certification as an option.
- Measuring range: 1 A to 3000 A
- Transformer Ratio: 1 A / 1 mA
- Connection: 4 mm / 1.6 in socket

Manufacturer: Chauvin Arnoux GmbH
Order no.: CA-D34N

The CA-D34N D Series Clamp on Tester for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Clamp on Tester is particularly suitable for busbars and cables with a large cross section. The Clamp on Tester adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 500 A, 1 A to 1000 A, 1 A to 1500 A
- Transformer Ratio: 0.5 A / 1 mA, 1 A / 1 mA, 1.5 A / 1 mA
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH

ISO-Certified Test Instruments Manufacturer

Custom-Made Test Instruments

PCE Instruments offers a wide range of stock products. However, despite an extensive selection of stock product offerings, sometimes a custom product is required to satisfy the specific requirements of a new, groundbreaking or special application.

Are you looking for custom test instruments?
Look no further than PCE Instruments. The DIN EN ISO 9001-certified PCE Product and Development Company GmbH produces customized test instruments tailored to meet the unique needs of a diverse customer base. By capitalizing on the expert knowledge and extensive experience of PCE’s industry-leading Tailored Test Instrumentsengineers and technicians to create custom-built test instruments, customers obtain measuring devices designed specifically for the task at hand.

Throughout the design, development and production process, PCE's engineers and technicians work hand-in-hand with each customer to ensure the final test instrument exceeds expectations. Specifications are clearly defined from the start of the project. Sensors, microprocessors and other electronic components are sourced from high-quality suppliers. Software is written to best support the customer's systems, processes and procedures. Qualified calibration laboratories are tasked with verifying the measurement accuracy of the custom test instrument, and rigorous testing is conducted to make certain that the device will function properly under the anticipated operating conditions.

If you are interested in pursuing the creation of a custom test instrument designed to accommodate an unusual or highly specialized measuring task, please contact the friendly and knowledgable staff at info@industrial-needs.com or +44 (0) 2380 987 035 for PCE Instruments UK, or at info@pce-americas.com or +1 (561) 320-9162 for PCE Americas Inc.