2 year Warranty
The data logger with USB interface PCE-428-EKIT, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The data logger with USB interface is a class 2 device and is equipped with an octave band frequency filter. Optionally, the data logger with USB interface PCE-428-EKIT can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a SPL meter over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time
weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
The data logger with USB interface PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The data logger with USB interface is equipped with an octave band frequency filter. Optionally, the data logger with USB interface can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a data logger with USB interface over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
- incl. ISO calibration certificate
The data logger with USB interface is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy data logger with USB interface has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level meter calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
This data logger with USB interface is a 12-channel temperature data logger that accommodates SD cards up to 16 GB in size. The optional software allows the data logger to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
This data logger with USB interface is a 12-channel temperature data logger that accommodates SD cards up to 16 GB in size. The optional software allows the data logger to connect to a PC via USB for direct data transfer and analysis via Microsoft Excel.
- 12-channel data logger for temperature (°C / °F)
- Works with type K, J, T, E, R and S thermocouple sensors
- Adjustable datalogging interval from 1 ... 3600 seconds per channel
- Includes 2 Type K sensors 1-meter in length
The data logger with USB interface is a class 2 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy data logger with USB interface has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).
- Measuring range: 25 ... 136 db(A)
- LXY (SPL), Leq (LXeq), LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN
- Frequency weighting: A, B, C and Z
- Time weighting: Fast (125 ms), slow (1 sec) and impulse (35 ms), decay (1500 ms)
- adjustable data-recording interval from 1 s ... 24 h
- 1/1 octave band filter (optional 1/3 octave band filter upgrade)
- incl. ISO Calibration Certificate
The data logger with USB interface is used to measure indoor / outdoor wet bulb globe temperature (WBGT), black globe temperature (TG), wet bulb temperature (WB), dew point temperature, air temperature (TA) and relative humidity. Thus, this multipurpose data logger with USB interface is an ideal tool for evaluating heat stress risks in different work environments.
- Programmable WBGT alarm setting with audible and visual alerts
- Manual (push-button) or automatic (adjustable 1 ... 3600 sec) sampling
- SD card memory (1 ... 16 GB) allows for quick and easy data transfer to a PC
- Automatic range: 30 ... 130 dB
- Manual range: 30 ... 80 / 50 ... 100 / 80 ... 130 dB
- Resolution: 0.1 dB
- Accuracy: ±1.4 dB
- Memory capacity: 32700 values
- incl. software for LEQ calculation
Important! The LEQ value is only calculated by the software after the data transfer from the device to the PC or laptop.
- Automatic range: 30 ... 130 dB
- Manual range: 30 ... 80 / 50 ... 100 / 80 ... 130 dB
- Resolution: 0.1 dB
- Accuracy: ±1.4 dB
- Memory capacity: 32700 values
- incl. software for LEQ calculation
- incl. ISO calibration certificate
Important! The LEQ value is only calculated by the software after the data transfer from the device to the PC or laptop.