Technical Data | |
Housing | |
Dimensions | 227 x 145 x 130 mm / 8.9 x 5.7 x 5.1" |
Weight | 0.5 kg / 1 lb 1 oz |
Protection | IP67 |
Electrical parameter | |
Input voltage range | 9-36 VDC |
Current consumption (without dome heating) |
120 mA (in calm weather
@24V); 360 mA (from about 7 m/s wind @24V) |
Heating dome | 24 VA @ 24 VDC |
Max. input power | 32.5 VA @ 24 VDC |
Environmental conditions | |
Perm. rel. humidity | 0 ... 100 % |
Perm. operating temperature | -40 ... +60 °C / -40 ... 140 °F |
Communication | |
Interfaces | RS485, 2-wire, half duplex; WLAN (2.4 GHz; 802.11b/g/n) |
Protocol | Modbus, UMB, UMB ASCII 2.0 |
Compass | |
Measuring range | 360 ° |
Accuracy | ±10 ° (free field) |
GPS | |
Accuracy | ±5 m (50% CEP) |
Environmental temperature | |
Measuring principle | PTC |
Measuring range | -40 ... +60 °C / -40 ... 140 °F |
Accuracy | ±1.0 °C (+5 ... +60 °C) else < ±2.0 °C |
Rel. humidity | |
Measuring principle | capacative |
Measuring range | 0 ... 100 % r.H. |
Accuracy | ±5% (at 20 °C and <80 % r.H.) |
Precipitation (liquid) | |
Measuring principle | Doppler radar |
Measuring range | 0 ... 100 mm/h |
Accuracy | 20% under laboratory conditions |
Precipitation | |
Parameter | rain, snow, sleet, freezing rain, hail |
Global radiation | |
Measuring principle | silicon pyranometer |
Measuring range | 0 ... 1500 W/m² |
Accuracy | 10% or ±120 W/m², larger value applies |
Sun | |
Measuring principle | calculated |
UVA / UVB index | |
Measuring principle | silicon pyranometer |
Measuring range | 0 ... 15 UV index |
Brightness (ambient light sensor) | |
Measuring principle | silicon pyranometer |
Measuring range | 0 ... 160 klx |
Accuracy | ±5 % of measuring range |
Twilight | |
Measuring principle | silicon pyranometer |
Measuring range | 0 ... 500 lx |
Accuracy | ±10 lx |
Air pressure | |
Measuring principle | capacative |
Measuring range | 300 ... 1100 hPa |
Accuracy | ±0.5 hPa (at room temp. 25 °C) |
Wind direction | |
Measuring principle | thermal |
Measuring range | 0 ... 359.9 ° |
Accuracy | ± 10 ° |
Wind speed | |
Measuring principle | thermal |
Measuring range | 0 ... 40 m/s / 0 ... 89 mph |
Accuracy | ±1 m/s (2.2 mph) or 5%, larger value applies |
PCE-KD5 is a display recorder or data logger for the capturing, monitoring and controlling of process parameters. The data logger is based on a Linux operating system and has three slots that can be equipped with several different inputs and outputs. Depending on your specific needs, it is possible to equip the PCE-KD5 data logger with up to 48 analog or binary inputs, 24 thermocouple inputs, 12 resistance temperature detector (RTD) inputs, 16 relays / solid state relays (SSRs) or 8 analog outputs.
- Up to 48 analog or binary inputs
- Up to 24 thermocouple inputs
- Up to 12 inputs for RTDs
- Up to 16 relays / SSRs
- Maximum sampling rate of 10 Hz
- 1.5 GB internal memory
**Not eligible for 30-day return policy due to custom configuration**
Price excl. VAT &. delivery
2 year Warranty