Voltmeter PCE-LCT 3

Order no.: PCE-LCT 3
£ 231.00
£ 277.20
4250348719096
PCE-LCT 3
price ex. (VAT / delivery)
Delivery time: 1-2 working days
Voltmeter PCE-LCT 3 
Multimeter for determining the leakage current / Temperature measurement with thermocouple / Inductive current measurement up to 150 A AC / Current probe opening 30 mm / Many measuring functions

The multimeter is the ideal measuring instrument to measure leakage currents. This is made possible by the extensive measuring range of the multimeter. Also, current measurements up to 150 A AC can be made with the multimeter. To test supply lines with a current of up to 150 A, the multimeter for the corresponding cable cross-section can be opened up to 30 mm. 

In addition to the current measurement, the multimeter can also measure voltages up to 600V directly. Because of the current and voltage measurement, the multimeter is the perfect measuring instrument to carry out measurements and analyzes on, for example, three-phase networks. For example, the continuity test can be used to find a wrong wiring in sub-distribution boxes.

- 30 mm current clamp opening
- Temperature measurement with thermocouple type K
- Current measurement up to 150 A AC
- Covers a wide range of measurements
- Voltage measurement up to 600V AC / DC RMS
- Transport bag for mobile use
AC current measurement 
measuring rangeResolution   AccuracyAccuracy
4-mA0.001-mA± (2% + 10 digits)± (3% + 5 digits)
40-mA0.01-mA± (2% + 10 digits)± (3% + 5 digits)
400-mA0.1-mA± (2% + 5 digits)± (3% + 3 digits)
4 A0.001 A± (2% + 5 digits)± (3% + 3 digits)
40 A0.01A± (2% + 10 digits)± (3% + 5 digits)
150 A0.1 A± (2% + 10 digits)± (3% + 5 digits)
    
Frequency range: 40 Hz ... 1 kHz (sine wave)
Maximum input current: 150 A AC
    

 
DC voltage 
measuring rangeResolutionAccuracy
4V0.001V± (0.5% + 4 digits)
40V0.01V 
400V0.1V 
600V1V 
   
Input impedance: 10 MΩ
Maximum input voltage: 600V AC / DC RMS
   

 
AC voltage  
measuring rangeResolutionAccuracy
4V0.001V
± (1% + 3 digits)
40V0.01V 
400V0.1V 
600V1V 
   
Input impedance: 10 MΩ
maximum input voltage: 600V AC / DC RMS
Frequency range: 40 Hz ... 1 kHz (sine wave)
   

 
Resistance 
measuring rangeResolutionAccuracy
400 Ω0.1 Ω± (0.8% + 3 digits)
4 kΩ0.001 kΩ 
40 kΩ0.01 kΩ 
400 kΩ0.1 kΩ 
4 MΩ0.001 MΩ 
40 MΩ0.01 MΩ± (1% + 3 digits)
   
Measuring voltage in open circuit: approx. 0.4V
Overvoltage protection: 600V AC / DC RMS
   

 
Continuity test 
measuring rangeResolutionAccuracy
Beep at < 40 Ω0,1Ω-
   
Overvoltage protection: 600V AC / DC RMS
   

 
Temperature 
measuring rangeResolutionAccuracy
-20 ... 0°C1°C± (3% + 5 digits)
-4 ... 32°F1°F 
-0 ... 400°C1°C± (1.5% + 5 digits)
32 ... 757°F1°F 
400 ... 1000°C1°C± (3% + 5 digits)
752 ... 1832°F1°F 
   
Overvoltage protection: 600V AC / DC RMS
The temperature accuracies do not include the accuracies of the temperature sensors
   

 
Capacity 
measuring rangeResolutionAccuracy
40.00 n0.01 nF± (3% + 8 digits)
400.0 nF0.1 nF 
4,000 μF0.001 μF 
40.00 μF0.01 μF 
400.0 μF0.1 μF 
4,000mF0.001 μF 
40.00 mF0.01 μF 
   
Overvoltage protection: 600V AC / DC RMS
   

 
Diode test 
measuring rangeResolutionAccuracy
3.2V0.001V-
   
Overvoltage protection: 600V AC / DC RMS
Test voltage: 3.2V
Forward current: 1-mA
The accuracies refer to the following ambient conditions: 23 ± 5°C / 9°F and < 75% RH
  
General specifications 
Maximum current clamp opening30 mm
Automatic shutdownAfter 30 minutes, can be deactivated
Power supply2 x 1.5V AAA battery
Measuring rate3 measurements per second
Display with overvoltage"OIL"
Maximum display4000
DisplayLCD display
Maximum working height2,000 m / 13,123 ft
Temperature coefficient0.1 x accuracy x °C, °F*
Operating conditions18 ... 28°C / 64 ... 82°F
Store control admixtures-10 ... 50°C / 14 ... 122°F
Dimensions213 x 62 x 38 mm / 8.4 x 2.4 x 1.5 in
WeightAbout 238 g / < 1 lb with batteries
  
*The temperature is the difference between the temperature of the operating conditions and the current ambient temperature.
 
Example:
Is the current ambient temperature greater than the temperature of the operating conditions
(50°C / 122°F (current ambient temperature)) - (40°C 104°F (operating temperature)) = 10°C / 50°F
Is the current ambient temperature less than the temperature of the operating conditions
(0°C / 32°F (operating temperature)) - (-5°C / 23°F (current ambient temperature)) = 5°C / 41°F
 


1 x Voltmeter PCE-LCT 3
1 x Transport bag
1 x Thermocouple type K
1 x Pair of test leads
2 x 1.5V AAA batteries
1 x User manual