Ozone Meter AQ-200

Order no.: AQ-200

£ 356.00
£ 427.20
AQ-200
price ex. (VAT / delivery)
Delivery time: 10 - 14 days
Ozone meter for measurement of ozone / Many different sensors available /
Broad range of application / Replaceable sensor head / Optional sensor for temperature and humidity

The Ozone Meter AQ-200 is a highly accurate instrument for measuring ozone concentrations in the air. The Ozone Meter can be equipped with four different heads that vary in their measurement range. Furthermore, the ozone tester has sensor heads for other gases available, which are automatically recognized when plugged into the device. Thus, you can use the ozone tester in many different areas. The possibilities of the ozone tester extend the use of ozone in your processes for bleaching oils, greases, wax, paper, synthetic fibers, cellulose or textiles,within the paper, textile, or lubricant productionies. Another field of application for the Ozone Meter is in cleaning, disinfection and sterilisation of swimming pools, water treatment facilities or after fire damage or water damage. With a head for lower measurements of up to 0.150 ppm, you can measure ozone concentrations that have a negative effect on the mental state of humans. Thanks to the leading GSS technology of the sensors, the Ozone Meter is not only high precision, it also has a long lifespan. The unique possibility to refresh the sensors makes their maintenance more economical than the maintenance of other types of sensors. Depending on the model, the measured concentrations may be written to the internal memory of the Ozone Meter via an analog interface with a 0... 5V output, or the output is transferred via a USB interface to a PC. Similarly, a remote kit is available as an option, allowing the Ozone Meter to take measurements in a secure room while the sensor is connected via cable to the Ozone Meter. The measured concentrations are displayed in ppm or mg / m³ on the LCD display.

Attention! No sensor head is included in the delivery, it must be ordered separately as an accessory!



- High accuracy and functionality
- Easy to operate and maintain
- Fast response time
- Interchangeable sensor heads
- LCD display
- Battery operation
- Sensor calibration function
- Max. / Min. / Average function

Technical Specification of the Gas Detector
Model 200 Series
Measurement unitsppm or mg/m³
FunctionsMax, Min, Average, Average 15 min
Sensor headRemovable / Replaceable, EOZ included
Display status indicatorBattery, sensor, standby
Calibration functionZero calibration
Model 200, 300 and 500 Series
Power supply12V DC
Rechargeable batteryLithium-Polymer 12V DC / 2700 mAh
Charger12.6V 2 A
Charging voltage12.6V
Charging time2... 3 hours
Lifecycle> 500 charges
HousingPC & ABS / IP20 & NEMA 1
Dimensions (incl. opt. sensors available)7.7 x 4.8 x 2.1 in 195 x 122 x 54 mm
Weight< 1 lb / 460 g (with battery)
ApprovalsEN 50082-1: 1997, EN 50081-1: 1992, CE

You can find the technical data on a variety of sensor heads to the ozone measurement device AQ series below in the "Optional accessories for Gas Detector AQ series".

Delivery Contents of the Ozone Meter
1 x Basic device AQ-200
1 x 12 V DC 800 mA AC/DC Power Supply Unit
1 x Battery Pack 12V
1 x Operating instructions  

Attention! No sensor head is included in the delivery, it must be ordered separately as an accessory!


Optional accessories for ozonemeter AQ series:

Sensors:

Gas
Code
Measuring range (ppm)Min.
(ppm)
Accuracy
(ppm)
Resolution 
(ppm)
Temp. °C/ Humid. %
GSS-Sensors (semiconductors sensors):
Ozone 
(O3)  OZU0 ... 0.150.001< ±0.005 %0.0010 ... +40 
10 ... 90 
Ozone 
(O3) OZL0 ... 0.50.001

< ±0.008 

0 ... 0.1

0.0010 ... +40 
10 ... 90 
Ozone 
(O3) EOZ0 ... 100.01 < ±0.1
0...1 0.010 ... +40 
10 ... 90 
Hydrogen
(H2) HA0 ... 50005< ±10 %10 ... +40 
10 ... 90 
Chlorine
(CL2) ECL0 ... 100.1< ±10 %0.010 ... +40 
10 ... 90 

Ozone (O3) 

Leckfin. OZK

0.010.010 ... +40 
10 ... 90 
Methane 
(CH4) MT0 ... 10,00010< ±15 %10 ... +40 
10 ... 90 
NMHC
VN0 ... 250.1< ±10 % 
0.1 ... 25 0.10 ... +40 
10 ... 90 
Tetrachlorethylene
(C2CL4) PE0 ... 2001< ±5 
0 ... 5010 ... +40 
10 ... 90 
(VOC) 
VM0 ... 250.1±10 %0.10 ... +40 
10 ... 90 
(VOC) 
VP0 ... 5001±10 %10 ... +40 
10 ... 90 

GSE-Sensors (electrochemical sensors):
Ammonia
(NH3) ENG0 ... 1000.2±10 %0.10 ... +40 
10 ... 90 
Carbon monoxide (CO) ECN0 ... 1000.1< ±1 
0... 100.10 ... +40 
10 ... 90 
Carbon monoxide
(CO) ECM0 ... 250.02< ±0.5
0 ... 50.010 ... +40 
10 ... 90 
Formaldehyde
(CH2O) EF0 ... 100.01< ±0.05
0 ... 0.50.010 ... +40 
10 ... 90 
Hydrogen sulfide (H2S) EHS0 ... 100.01< ±0.05
0 ...0.50.010 ... +40 
10 ... 90 
Hydrogen sulfide (H2S) EHT0 ... 1000.2< ±0.5
0 ... 50.10 ... +40 
10 ... 90 
Nitrogen dioxide (NO2) ENW0 ... 10.002< ±0.02 
0 ... 0.10.0010 ... +40 
10 ... 90 
Sulfur dioxide (SO2) ESO0 ... 100.01< ±0.05
0 ... 0.50.010 ... +40 
10 ... 90 
Sulfur dioxide (SO2) ESP0 ... 1000.2< ±0.05
0 ... 0.50.10 ... +40 
10 ... 90 

NDIR-Sensors (infrared sensors):
Carbon dioxide (CO2) CD0 ... 20002< ±5 % 
(the display)10 ... +40 
10 ... 90 
Carbon dioxide (CO2) CE0 ... 50005<± 5 % 
(the display)10 ... +40 
10 ... 90 
Carbon dioxide
(CO2) CF0 ... 5 %0.02 %<± 5 % 
(the display)0.01 %0 ... +40 
10 ... 90 

PID-Sensors (photoionization detector sensors):
VOC 
PDL0 ... 200.01< ±10 %0.010 ... +40 
10 ... 90 
VOC
PDH0 ... 10000.2< ±10 %0.10 ... +40 
10 ... 90 

Combined Sensors:
CO2
CO
PID
Code: MS20 ... 2000
0 ... 100
0 ... 252
0.1
0.01±40  + 3 %
±10 % 1 ...100
±10 % des Erg.1
0.1
0.010 ... +40 
10 ... 90 
CO2
CO
Code: MS10 ... 2000
0 ... 1002
0.1±40  + 3 %
±10 % 1 ...1001
0.10 ... +40 
10 ... 90