Handheld Multimeter / Oscilloscope PCE-OC 2

Order no.: PCE-OC 2
£ 80.00
£ 96.00
4250348712257
PCE-OC 2
price ex. (VAT / delivery)
Delivery time: 1-2 working days
Digital multimeter with 20 MHz bandwidth / Integrated multimeter / 
Internal memory for up to 50 waveforms and readings / 
LC display with 2 brightness levels / Frequency counter/ USB interface

The handheld digital multimeter is a versatile and universally applicable instrument, combined with an oscilloscope and a True RMS multimeter. The bandwidth of the handheld oscilloscope multimeter can be up to 20 MHz. The digital multimeter was developed for practical and mobile use and is suitable for fault detection thanks to the versatile equipment

The digital multimeter is an ideal companion for the service technician on site or in any electrical workshop. The brightness of the LC display of the digital multimeter with a resolution of 128 x 128 pixels can be set in 2 levels and thus individually tailored to the user or location. Furthermore, the digital multimeter has an internal memory in which both up to 50 waveforms as well as measured values can be stored. 

The integrated multimeter is equipped with the standard functions voltage, current and resistance measurement as well as diode and continuity tests and also has the additional functions frequency and capacitance measurement. The USB interface can be used to charge the digital multimeter via the PC.  

- Analog bandwidth: 20 MHz
- Auto range multimeter
- Auto-setting for easy handling
- LC display with 2 brightness levels
- USB interface for data transmission
- Frequency counter
- Mains or battery operation
- Internal memory for up to 50 readings

Measuring function    
DC voltage measurement    
Range Resolution Accuracy
400.0 mV 0.1 mV ±(0.75 % + 10 dgt.)
4.000 V 1 mV ±(0.75 % + 10 dgt.)
40.00 V 10 mV ±(0.75 % + 10 dgt.)
400.0 V 100 mV ±(0.75 % + 10 dgt.)
1000 V 1 V ±(1.5 % + 10 dgt.)
     
AC voltage measurement    
Range Resolution Accuracy
400.0 mV 0.1 mV 50 Hz ... 1 kHz: ±(1 % + 10 dgt.)
4.000 V 1 mV 400 Hz ... 10 kHz: ±(1 % + 10 dgt.)
40.00 V 10 mV (not defined above 10 kHz)
400.0 V 100 mV  
750 V 1 V 50 Hz ... 1 kHz: ±(1.5 % + 10 dgt.)
     
DC current measurement    
Range Resolution Accuracy
40.00 mA 10 µA ±(1.2 % + 10 dgt.)
400.0 mA 100µA ±(1.2 % + 10 dgt.)
4.000 A 1 mA ±(1.2 % + 10 dgt.)
20.00 A 10 mA ±(1.2 % + 10 dgt.)
     
AC current measurement    
Range Resolution Accuracy
40.00 mA 10 µA 50 Hz ... 1 kHz: ±(1.5 % + 10 dgt.)
400.0 mA 100µA (not defined above 1 kHz)
4.000 A 1 mA  
20.00 A 10 mA  
     
Resistance measurement    
Range Resolution Accuracy
400.0 Ω 0,1 Ω ±(1.0 % + 5 dgt.)
4.000 kΩ 1 Ω ±(1.0 % + 5 dgt.)
40.00 kΩ 10 Ω ±(1.0 % + 5 dgt.)
400.0 kΩ 100 Ω ±(1.0 % + 5 dgt.)
4.000 MΩ 1 kΩ ±(1.0 % + 5 dgt.)
40.00 MΩ 10 kΩ ±(3.0 % + 5 dgt.)
     
Capacitance    
Range Resolution Accuracy
51.20 nF 1 pF ±(2 % + 10 dgt.)
512.0 nF 10 pF ±(1 % + 3 dgt.)
5.120 µF 100 pF ±(1 % + 3 dgt.)
51.20 µF 1 nF ±1.5 % + 3 dgt.)
100.0 µF 10 nF -
     
Frequency counter    
Range Resolution Accuracy
5.12 Hz ... 5.12 MHz 0.1 ... 1 kHz ±(1 % + 5 dgt.)
    at a signal amplitude of
    > 3 Vpp, ACV or 20 mA RMS, AC A
     
Frequency ratio    
Range Resolution Accuracy
0.1 ... 99.9 % 0.1 % -
     
Diode measurement open circuit 1.5 V, max. current 1.5 mA
Continuity test Beep at> 30 Ω
Automatic measuring range at every function
Exceeding the measuring range    O.L. is displayed
Measuring rate 2.5 times / sec.
dB (-80 ... +80 dB) reference 2, 3, 8, 16, 50, 75, 93, 110, 125,
  135, 150, 300, 600, 900, 1000, 1200 Ω
Fuse 0.5 A / 250 V; 20 A / 500 V
   
Oscilloscope  
Analog bandwidth DC 20 MHz (50 mV / div ... 2 V / div)
  DC 10 MHz (5 V / div ...10 V / div)
  >10 V / div for reference only
Real-time sample rate 80 MS/s
Vertical resolution 8 Bits
Nonlinearity ± 1 Bit
Channel number 1
Input coupling DC/AC/GND
Display Vertical ±4.8 horizontal 12.8
Vertical display area 50 mV/div ... 200 V/div
Vertical accuracy ± (5 % + 0.1 div.)
Horizontal display area 31.25 ns/div ... 20 s/div
Horizontal accuracy ± (0.01 % + 0.1 div.)
Trigger edge Increases in length / falls in length
Trigger level ± 12 div (at each step 0.1 div)
Trigger position ± 6 div (at each step 0.1 div)
Automatic settings Vertical amplitude and automatic settings
Measurement mode Automatic / Normal / Single
Automatic measuring function Vpp, Vavg, RMS, dBm
Cursor measurement function dV, dt, 1/dt (frequency)
Automatic measurement accuracy     ± (5 % + 0.1 div)
Automatic zero reference In DC/dB measurement
Recording length 12.8 div
   
General technical data  
Display 128 x 128 pixel LC-display
Backlight white LED, 2 brightness levels
Power supply battery
Li-Ion battery, 3.7 V, 18650
Power supply mains Primary: 100 ... 240 V 50/60 Hz
  Secondary: 5 VDC, 1.5 A
Memory 50 measurement data
  (one DMM and DSO are recorded per measurement file)
Battery life ca. 6 ... 8 hours
Operating conditions 0 ... 50°C / 32 ... 122°F; <75 % r.H.
Dimensions 86 x 186 x 32 mm / 3.39 x 7.32 x 1.26 in
Input impedance 10 MΩ
Auto power off Switch-off, 5 .. 60 min. adjustable
Charging time ca. 3 hours
Storage conditions -10 ... 60°C / -14 ... 140°F
Weight 325 g / 0.72 lb
Standards IEC1010 CAT III 1000V

1 x Handheld Multimeter / Oscilloscope PCE-OC 2
1 x Set of test leads
1 x AC adapter / charger
1 x USB cable
1 x Carrying case
1 x User manual