IoT Data Logger PCE-NR30IoT

Order no.: PCE-NR30IoT
£ 262.00
£ 314.40
PCE-NR30IoT
price ex. (VAT / delivery)
Note: When using the PCE-S4AO, the Modbus interface cannot be used for other systems.
Delivery time: Check availability
IoT Data Logger up to 63 A for Top-Hat DIN rail mounting / 1 and 3-phase measurement / memory / Ethernet / LC display / alarm relay / Modbus RTU, TCP / HTTP and FTP function / MQTT protocol for Industry 4.0 applications


The IoT Data Logger is able to measure currents directly up to 63 A AC. The IoT Meter can also be used with the aid of x / 1A or x / 5A current transformers. The IoT Meter measures network parameters of symmetrically and asymmetrically loaded single-phase 2-wire systems and three-phase 3 or 4-wire systems. The PCE-NR30 power indicator is also able to measure harmonics up to the 51st order. The power indicator impresses with its high accuracy class of 0.2s. Thus, the indicator meter is also suitable for demanding measurement and research tasks. The display always provides information about all network parameters and the maximum and minimum measured values ​​can be shown directly at the push of a button. Two adjustable alarm outputs round off the overall package of the power indicator. Optionally, the power indicator can be expanded by 4 x 4 ... 20 mA or 0 ... 10 V outputs via the PCE-S4AO module.

The IoT Data Logger is mounted on the top hat rail and is built according to EN62208. An RS485 and an Ethernet interface are available as standard. The interface is accessed via Modbus RTU or Modbus TCP. It is also possible to read out the power indicator via HTTP request or via FTP. The power indicator can be set using the buttons on the front or via the USB interface using the programming software.

 


- Measurement of 54 network parameters
- 1-phase 2-wire or 3-phase 3- or 4-wire symmetrical and asymmetrical measurement
- Accuracy class 0.2s
- Illuminated LC display
- Direct measurement up to 63A and indirect measurement via current transformer (x / 1A or x / 5A)
- Scaled display when measuring with the aid of current transformers
- Storage of minimum and maximum values
- 2 configurable alarm outputs
- Optional analog outputs
- RS485 Modbus RTU interface
- Ethernet interface Modbus TCP / HTTP / FTP  / MQTT protocol for Industry 4.0 applications
- 8 GB memory
- Configuration by software
- DIN rail mounting
Technical Data
Measuring range
Current (class 0.2)
1 A AC
5 A AC
63 A AC

0.1 ... 1.2 A
0.5 ... 6.0 A
0.1 ... 70 A
max. display range: 100kA
Voltage L-N (class 0.2)
57.7 V AC
100 V AC
230 V AC
400 V AC

11.5 ... 70 V
20 ... 120 V
46 ... 276 V
80 ... 480 V
max. display range: 480 kV
Voltage L-L (class 0.5)
100 V AC
170 V AC
400 V AC
690 V AC

20 ... 120 V
34 ... 204 V
80 ... 480 V
138 ... 830 V
max. display range: 830 kV
Active power (class 0.5) ± 1999.9 W
max. display range: ± 1999.9 MW
Reactive power (class 1) ± 1999.9 Var
max. display range: ± 1999.9 MVar
Apparent power (class 0.5) 0 ... 1999.9 Va
max. display range: 0 ... 1999.9 MVA
Active energy (class 0.2s) ± 1999.9Wh
max. display range: ± 1999.9 MWh
Reactive energy (class 1) ± 1999.9 Varh
max. display range: ± 1999.9 MVarh
Apparent energy (class 0.5) 0 ... 1999 VAh
max. display range: 0 ... 1999.9 MVAh
Active power factor -1 .... 1
Coefficient tg
-999.99 ... 999.99
Frequency 45 ... 65 Hz
Harmonic distortion 0 ... 100 %
Harmonics current and voltage up to the 51st order 0 ... 100 %
Additional Technical Data
Relay output
2 x relays (250 V / 0.5 A AC or 30 V / 5 A)
USB
USB 1.1 / 2.0
RS485 interface Modbus RTU
8N2, 8E1, 8O1, 8N1
Address: 1 ... 247
Baud rate: 4800, 9600,19200, 38400, 57600, 115200
Ethernet 10/100 protocols: TCP, HTTP. FTP, MQTT
Display20 x 4 LCD lines with lighting
Dimensions105 x 110 x 60 mm
Weight 300 g
Protection class Front: IP50
Connection side: IP00
Power supply 85 ... 253 V AC / 90 ... 300 V DC
20 ... 40 V AC / 20 ... 60 V DC
Power consumption 6 VA
Power loss Voltage side: 0.5 VA
Current side: 0.1 VA (1/5 A) / 2 VA (63 A)
Heating time 5 minutes
Operating conditions -10 ... 55 °C / 0 ... 95 % r.H.
Operating positionany
Overload Voltage: 2 x Un (5 seconds)
Current: 50 A at 1/5 A (1 second)
630 A to 63 A (1 second)
Electromagnetic compatibility EN 61000-6-2
EN 61000-6-4
Housing insulation double according to EN61010-1
Degree of pollution 2
Installation category III
Operating conditions
-10 ... 55 °C / 0 ... 95 % r.H.


1 x IoT Data Logger PCE-NR30IoT in the selected configuration