2 year Warranty
VHF-Band Moisture Meter Crushed Stone, Gravel, Ore (conveyor). The device is resistant to corrosion (stainless steel and dielectric materials) and can operate in the conditions deviating from the norm, for example, at temperatures of 145 °C. The humidity detector probe can be mounted on the walls in the hoppers, in pipelines or on trays in conveyors. Due to pluggable design this version of the humidity detector can also be used for soil moisture control.
- Measurement range: 0 ... 100 %
- Limits of error: <0.5% below 10% moisture
- Range of working temperatures:
0 ... +90 °C (industrial version)
0 ... +115 °C (extended temperature range)
0 ... +250 °C (drying kilns)
VHF-Band Moisture Meter Crushed Stone, Gravel, Ore (conveyor). The device is resistant to corrosion (stainless steel and dielectric materials) and can operate in the conditions deviating from the norm, for example, at temperatures of 145 °C. The moisture meter probe can be mounted on the walls in the hoppers, in pipelines or on trays in conveyors. Due to pluggable design this version of the moisture meter can also be used for soil moisture control.
- Measurement range: 0 ... 100 %
- Limits of error: <0.5% below 10% moisture
- Range of working temperatures:
0 ... +90 °C (industrial version)
0 ... +115 °C (extended temperature range)
0 ... +250 °C (drying kilns)
VHF-Band Moisture Analyzer Crushed Stone, Gravel, Ore (conveyor). The device is resistant to corrosion (stainless steel and dielectric materials) and can operate in the conditions deviating from the norm, for example, at temperatures of 145 °C. The moisture analyzer probe can be mounted on the walls in the hoppers, in pipelines or on trays in conveyors. Due to pluggable design this version of the moisture analyzer can also be used for soil moisture control.
- Measurement range: 0 ... 100 %
- Limits of error: <0.5% below 10% moisture
- Range of working temperatures:
0 ... +90 °C (industrial version)
0 ... +115 °C (extended temperature range)
0 ... +250 °C (drying kilns)
VHF-Band Moisture sensor Crushed soil, sand, stone, Gravel, Ore. The device is resistant to corrosion (stainless steel and dielectric materials) and can operate in the conditions deviating from the norm, for example, at temperatures of 250 °C. The moisture sensor probe can be mounted on the walls in the hoppers, in pipelines or on trays in conveyors. Due to pluggable design this version of the moisture sensor can also be used for soil moisture control.
- Measurement range: 0 ... 100 %
- Limits of error: <0.5% below 10% moisture
- Range of working temperatures:
0 ... +90 °C (industrial version)
0 ... +115 °C (extended temperature range)
0 ... +250 °C (drying kilns)
VHF-Band Moisture Analyzer Crushed Stone, Gravel, Ore (conveyor). The device is resistant to corrosion (stainless steel and dielectric materials) and can operate in the conditions deviating from the norm, for example, at temperatures of 145 °C. The moisture Analyzer probe can be mounted on the walls in the hoppers, in pipelines or on trays in conveyors. Due to pluggable design this version of the moisture analyzer can also be used for soil moisture control.
- Measurement range: 0 ... 100 %
- Limits of error: <0.5% below 10% moisture
- Range of working temperatures:
0 ... +90 °C (industrial version)
0 ... +115 °C (extended temperature range)
0 ... +250 °C (drying kilns)
The dual infrared thermometer is used for fast surface temperature measurement.The two laser points of the infrared thermometer PCE-895 mark the exact measuring point and thus offer excellent assistance with the temperature measurement.
- Temperature measurement up to 1600 °C / 2912 °F
- Cross laser thermometer
- K-Type or infrared measurement
- Optical resolution 60:1
- Adjustable emissivity
- Can be calibrated
- Suitable for long-term measurements
PCE-TC 28 is an infrared thermometer designed for non-contact temperature measurement. This infrared thermometer has adjustable emissivity and captures infrared images. This infrared thermometer also can take normal pictures, as well as a mixture of both normal and infrared, due to the built-in digital camera.
- Measurement range: -20 ... +600°C / -4 ... 1112°F
- Accuracy: ± 2%, ± 2°C / 3.6°F
- Frequency image recording: 9 Hz
- Camera: 32 x 31 Pixel
PCE-TC 28 is an infrared thermometer designed for non-contact temperature measurement. This infrared thermometer has adjustable emissivity and captures infrared images. This infrared thermometer also can take normal pictures, as well as a mixture of both normal and infrared, due to the built-in digital camera.
- Measurement range: -20 ... +600°C / -4 ... 1112°F
- Accuracy: ± 2%, ± 2°C / 3.6°F
- Frequency image recording: 9 Hz
- Camera: 32 x 31 Pixel
- incl. ISO Calibration Certificate
The dual infrared thermometer is used for fast surface temperature measurement. The two laser points of the infrared thermometer PCE-895-ICA mark the exact measuring point and thus offer excellent assistance with the temperature measurement.
- Temperature measurement up to 1600°C / 2912°F
- Cross laser thermometer
- K-Type or infrared measurement
- Optical resolution: 60:1
- Adjustable emissivity
- Suitable for long-term measurements
- Incl. ISO Calibration Certificate
Infrared thermometer for temperatures up to + 500 °C. The measured data can be stored and snet to a computer later on, but the main significant feature of this infrared thermometer is the built-in printer. This makes the test instrument very attractive for use in food applications. As all test equipment, this infrared thermometer is delivered manufacturer calibrated and can additionally be certified to ISO.
- Temperature range: -40 to 500 °C / -40 ... 932 °F
- Resolution: 0.1 °C / 0.18 °F
- Accuracy: ±2 % of reading or ±2 °C / 3.6 °F
- Optical resolution: 8:1
- Emissivity: 0.3 to 1.0 (adjustable)
- Interface: RS-232
- Display: LCD