HVAC Meter PCE-DC 10-ICA incl. ISO Calibration Certificate

Order no.: PCE-DC 10-ICA
ISO Calibration
£ 145.00
£ 174.00
PCE-DC 10-ICA
price ex. (VAT / delivery)
Delivery time: 10 - 14 days
HVAC Meter incl. ISO Calibration Certificate
Digital multimeter with "SMART" function / Current probe opening of 26 mm (1") / Automatic shutdown after 15 minutes / Backlight with torch/flashlight / Extensive measuring functions / For fast and mobile use

The HVAC meter is an ideal measuring device for the fast measurement of currents and voltages. To perform current measurements, a digital multimeter must be connected in series to the load. With this digital multimeter, current measurements directly on the supply line can be performed inductively without disconnecting them to switch on a digital multimeter. Thanks to this inductive current measurement, the risk of electric shock is drastically reduced because the operator has no direct contact with the supply line thanks to the digital multimeter.

In addition to current measurement of up to 600 A AC, the HVAC meter can also measure voltages up to 600V AC/DC, resistors, capacitances and the voltage network frequencies. Another special feature of the digital multimeter is the "SMART" function. With this function the digital multimeter sets the measuring function itself. Thus, the digital multimeter is also used in schools, training centers or other educational institutions.

- Current measurement up to 600 AAC
- Maximum forceps opening 26 mm / 1"
- Voltage measurement up to 600V AC / DC
- Three measurements per second
- "SMART" function facilitates operation
- Backlit LCD display
- incl. ISO Calibration Certificate
Measuring function  
AC current  
Measuring range Resolution Accuracy
2 A 0.01 A ±(2.5 % + 8 digits)
20 A 0.01 A ±(2.5 % + 8 digits)
200 A 0.1 A ±(2.5 % + 8 digits)
600 A 1 A ±(3.0 % + 10 digits)
     
Frequency range: 45 ... 65 Hz
The frequency is only displayed from a current of 0.2A upwards.
Maximum input current: up to 600 A for no more than 60 seconds.
Accuracy refers to RMS sine waves.
     
Measuring function  
AC voltage  
Measuring range Resolution Accuracy
6 V 0.01 V ±(0.8 % + 5 digits)
60 V 0.1 V  
600 V 1 V  
     
Input impedance: 10 MΩ
Overvoltage protection 600 V AC/DC rms
Smallest measurable voltage: 1 V AC/DC
Frequency range: 45 ... 65 Hz
Accuracy refers to RMS sine waves
If a current is detected during the voltage measurement, "Err" appears on the display
     
Measuring function  
DC voltage  
Measuring range Resolution Accuracy
6 V 0.01 V ±(0.5 % + 3 digits)
60 V 0.1 V  
600 V 1 V  
 
Input impedance: 10 MΩ
Overvoltage protection 600 V AC/DC rms
Smallest measurable voltage: 1 V AC/DC
 
Measuring function  
Resistance  
Measuring range Resolution Accuracy
2 kΩ 0.001 kΩ ±(0.8 % + 3 digits)
20 kΩ 0.01 kΩ ±(0.8 % + 3 digits)
200 kΩ 0.1 kΩ ±(0.8 % + 3 digits)
2 MΩ 0.001 MΩ ±(0.8 % + 3 digits)
10 MΩ 0.01 MΩ ±(1 % + 5 digits)
     
Measuring voltage in open circuit: ca. 0.4 V
Overvoltage protection: 250 V AC/DC rms
Continuity test
Audible signal at <40 Ω
Measuring voltage in open circuit: ca. 0.4 V
Overvoltage protection: 250 V AC/DC rms
     
Measuring function  
Frequency  
Measuring range Resolution Accuracy
60 Hz 0.1 Hz ±(1 % + 5 digits)
600 Hz 1 Hz  
3 kHz 10 Hz  
     
Total measuring range: 40 ... 3 kHz
Minimum voltage: >1 AC RMS (the measurement frequency will increase with the voltage)
Overvoltage protection: 600 V AC/DC rms
 
Measuring function  
Duty cycle  
Measuring range Resolution Accuracy
10 ... 90 % 1 % ±2 %
     
Maximum current clamp opening 26 mm / 1"
Insulation CAT III 600 V
Measuring rate ca. 3 measurements per second
Display 3 5/6 digit LCD
Display range
5999, 1999 for resistance measurement
Measurement outside the measuring range "OL" display
Automatic shutdown after 15 minutes, can be deactivated
Coefficients 0.1 x accuracy x °C*
Power supply 3 x 1.5 V AAA batteries
Operating conditions 0 ... 40 °C / 32 ... 104 °F, <80 % RH
Storage conditions -10 ... 60 °C / 14 ... 140 °F, <70 % RH (without batteries)
Maximum working height 2000 m / 6561 ft
Dimensions 204 x 78 x 43 mm / 8 x 3.1 x 1.7"
Weight ca. 195 g / 6.8 oz
   
Accuracies are given at ambient conditions of 18 ... 28 °C, 65 ... 83 °F. *The temperature is the difference between the temperature of the operating conditions and the current ambient temperature.
   
Example:  
Is the current ambient temperature greater than the temperature of the operating conditions
(50 °C / 122 °F (current ambient temperature)) - (40 °C / 104 °F (operating temperature)) = 10 °C / 50 °F
Is the current ambient temperature less than the temperature of the operating conditions
(0 °C / 32 °F (operating temperature)) - (-5 °C / 23 °F (current ambient temperature)) = 5 °C / 41 °F
 

1 x HVAC Meter PCE-DC 10-ICA
1 x Pair of test leads
1 x Transport bag
3 x 1.5V AAA batteries
1 x User manual
1 x ISO Calibration Certificate

N.B. Calibration certificates are issued specifically for the customer and are excluded from the right of return.