Order no.: AQ-300 Set ECL

Chlorine Gas Leak Detector AQ-300 Set ECL

£ 979.00
£ 1,174.80
AQ-300 Set ECL
price ex. (VAT / delivery)
Delivery time: 10 - 14 days

Description

Chlorine gas leak detector / Replaceable sensor head / Alarm function /
Data logger / Optional sensor for temperature and humidity

The chlorine gas leak detector is a highly accurate measuring device for measuring the chlorine concentration in our ambient air. Furthermore, sensor heads for other gases are also available for the chlorine measuring device, which are automatically recognized when they are plugged into the device. So you can use the chlorine meter in many different areas.

By using leading GSS Technology sensors, the Aeroqual gas leak detector has a high level of measurement accuracy and a very long service life for the sensor heads. The unique possibility of refreshing the sensors from the chlorine measuring device offers cost-effective maintenance of the devices compared to other sensor technologies. Depending on the model, the measured concentrations can be output via an analogue interface with a 0…5 V output signal, written to the internal memory of the chlorine measuring device or transferred to a PC via a USB interface.

A remote kit is also optionally available, which allows measurements to be taken with the chlorine meter in a safe room while the sensor is connected to the chlorine meter by cable. Due to the simplicity of the operation, the alarm thresholds for the optical or acoustic signaling can be changed in a very short time. In addition to the measured concentrations, which are displayed in ppm or mg/m³, the LCD display also shows the high and low alarms.

Highlights

- High accuracy and functionality
- Easy to operate and maintain
- Fast response time
- Interchangeable sensor heads
- LCD display
- Battery operation
- Alarm function
- Sensor calibration function
- Max. / Min. / Average function
- Analog output

Specification

Model 300 Series
as Model 200 Series, in addition
Alarm function"High", "Low", Mute
Alarm outputTransistor output, 150 mA max
Low Alarm, High Alarm & Control
Analog output0 ... 5 V
Location IDStorage of the measuring location
Model 200, 300 and 500 Series
Power supply12 V DC
Rechargeable batteryLithium-Polymer 12 V DC / 2700 mAh
Charger12.6 V 2 A
Charging voltage12.6 V
Charging time2 ... 3 hours
Lifecycle> 500 charges
HousingPC & ABS / IP20 & NEMA 1
Dimensions (incl. sensor)195 x 122 x 54 mm / 7.7 x 4.8 x 2.1"
Weight< 460 g / 16.2 oz (with batteries)
ApprovalsEN 50082-1: 1997, EN 50081-1: 1992, CE



Optional accessories for the gas detector:

Sensors:

Gas
Code
Meas. (ppm)Min.
(ppm)
Meas.
(ppm)
Resolution. 
(ppm)
Temp. °C/ humidity. %
GSS sensors (semiconductor sensors):
Ozone
(O3)  OZU
0 ... 0.150.001< ±0.005 %0.0010 ... +40 
10 ... 90 
Ozone
(O3) OZL
0 ... 0.50.001

< ±0.008 

0 ... 0.1

0.0010 ... +40 
10 ... 90 
Ozone
(O3) OZG
0 ... 100.01 < ±0.1
0...1 
0.010 ... +40 
10 ... 90 
Hydrogen
(H2) HA
0 ... 50005< ±10 %10 ... +40 
10 ... 90 
Chlorine
(CL2) ECL
0 ... 100.1< ±10 %0.010 ... +40 
10 ... 90 

Ozone (O3) 

Leakage finder OZK


0.01
0.010 ... +40 
10 ... 90 
Methane
(CH4) MT
0 ... 10,00010< ±15 %10 ... +40 
10 ... 90 
NMHC
VN
0 ... 250.1< ±10 % 
0.1 ... 25 
0.10 ... +40 
10 ... 90 
Tetrachlorethylene
(C2CL4) PE
0 ... 2001< ±5 
0 ... 50
10 ... +40 
10 ... 90 
(VOC) 
VM
0 ... 250.1±10 %0.10 ... +40 
10 ... 90 
(VOC) 
VP
0 ... 5001±10 %10 ... +40 
10 ... 90 

GSE sensors (electrochemical sensors):
Ammonia
(NH3) ENG
0 ... 1000.2±10 %0.10 ... +40 
10 ... 90 
Carbon monoxide (CO) ECN0 ... 1000.1< ±1 
0... 10
0.10 ... +40 
10 ... 90 
Carbon monoxide
(CO) ECM
0 ... 250.02< ±0.5
0 ... 5
0.010 ... +40 
10 ... 90 
Formaldehyde
(CH2O) EF
0 ... 100.01< ±0.05
0 ... 0.5
0.010 ... +40 
10 ... 90 
Sulfur-
hydrogen (H2S) EHS
0 ... 100.01< ±0.05
0 ...0.5
0.010 ... +40 
10 ... 90 
Sulfur-
hydrogen (H2S) EHT
0 ... 1000.2< ±0.5
0 ... 5
0.10 ... +40 
10 ... 90 
Nitrogen dioxide (NO2) ENW0 ... 10.002< ±0.02 
0 ... 0.1
0.0010 ... +40 
10 ... 90 
Sulfur dioxide (SO2) ESO0 ... 100.01< ±0.05
0 ... 0.5
0.010 ... +40 
10 ... 90 
Sulfur dioxide (SO2) ESP0 ... 1000.2< ±0.05
0 ... 0.5
0.10 ... +40 
10 ... 90 

NDIR sensors (infrared sensors):
Carbon dioxide (CO2) CD0 ... 20002< ±5 % 
(of the display)
10 ... +40 
10 ... 90 
Carbon dioxide (CO2) CE0 ... 50005<± 5 % 
(of the display)
10 ... +40 
10 ... 90 
Carbon dioxide
(CO2) CF
0 ... 5 %0.02 %<± 5 % 
(of the display)
0.01 %0 ... +40 
10 ... 90 

PID sensors (photoionization detector sensors):
VOC 
PDL
0 ... 200.01< ±10 %0.010 ... +40 
10 ... 90 
VOC
PDH
0 ... 10000.2< ±10 %0.10 ... +40 
10 ... 90 

Combi sensors:
CO2
CO
PID
Code: MS2
0 ... 2000
0 ... 100
0 ... 25
2
0.1
0.01
±40  + 3 %
±10 % 1 ...100
±10 % of result
1
0.1
0.01
0 ... +40 
10 ... 90 
CO2
CO
Code: MS1
0 ... 2000
0 ... 100
2
0.1
±40  + 3 %
±10 % 1 ...100
1
0.1
0 ... +40 
10 ... 90 

Delivery Scope

1 x Chlorine Gas Leak Detector AQ-300 SET ECL
1 x Sensor head ECL (chlorine (Cl2) 0-10 ppm)
1 x 12 V DC 800 mA AC/DC plug-in power supply
1 x Battery pack 12 V
1 x Instruction manual

Downloads