Environmental Tester PCE-353N-ICA Incl. ISO Calibration Certificate

Order no.: PCE-353N-ICA
ISO Calibration
£ 159.00
£ 190.80
4250348720252
PCE-353N-ICA
price ex. (VAT / delivery)
Delivery time: 10 - 14 days
Environmental tester PCE-353N-ICA incl. ISO Calibration Certificate
Industrial Safety Gauge with graphic display / DC output up to 2.5V / Windbreak /  Various measuring functions / Frequency weighting A and C / Data memory / For mobile and stationary use / Tripod mount

The safety device is a sound measuring instrument with an adjustable measuring range of 30 ... 130 dB. On the one hand, the measured values ​​are displayed as a normal numerical value and on the other hand also graphically in the measuring range set by the operator. A special feature of the health and safety measuring instrument is the measurement function LEQ (equivalent continuous sound level) in addition to the normal sound measurement. This measurement function is a globally recognized measure of the average sound exposure, taking into account the duration, frequency and intensity of the individual sound events.

In addition to the sound measurement, the safety device can also be connected to a process interface. Here, the safety device generates a linear voltage signal of up to 2.5V. With the tripod mount on the back of the safety device can be optimally positioned the application. Thanks to the 9V interface, the safety device can be permanently operated stationary.

- Measuring range 30 ... 130 dB
- Measurement functions Lp, LAeq, LAe, LCpeak
- DC output for process connection
- For stationary and mobile use
- Backlit LCD display
- 1/2" microphone with windscreen
Measuring range

30 ... 130 dBA

  35 ... 130 dBC
Accuracy ± 1.5 dB (at 1 KHz and 94 dB), Class 2
Resolution digital display 0.1 dB
Resolution bar graph 1 dB
Frequency A and C
Manual measuring range 30 ... 80 dB
  50 ... 100 dB
  60 ... 110 dB
  80 ... 130 dB
Dynamic display area 50 dB
Display outside the measuring range      "Over" at overrange
  "Under" at measuring range undershoot
Measurement functions Lp, LAeq, LAe, LCpeak
Data storage 10 readings
DC output 0 ... 2.5V, 25mV / dB
Output resistance 600 Ω
Term review Fast (125 ms)
  Slow (1 s)
Frequency range 31.5 Hz ... 8 kHz
Power supply battery 9V block battery
Power supply power supply 9VDC, 100-mA
Sound sensor
1/2" polarized condenser microphone
Display LCD display, 4 digits
Operating conditions 0 ... 40°C / 32 ... 104°F, < 80% rh
working height < 2000 m / 6561.7 ft
Dimensions 200 x 72 x 35 mm / 7.9 x 2.8 x 1.4 in
Weight About 290 g / < 1 lb
Standard IEC 61672-1: 2002 (Class II),
  JJG 188-2002
   


1 x Environmental tester PCE-353N-ICA
1 x Connection cable for DC output
1 x Windbreak
1 x 9V block battery
1 x Transport bag
1 x Operating Instructions
1 x ISO calibration certificate