Electrical Tester PCE-HDM 20
TRMS digital multimeter for current, voltage, capacity, frequency and resistance /
CAT IV 600 V / CAT III 1000 V / with contactless temperature measurement via infrared /
MAX, MIN and HOLD function

The Electrical Tester PCE-HDM 20 is a universal measuring instrument. The Electrical Tester PCE-HDM 20 allows a variety of measurement projects. This makes it easy to investigate current, voltage, capacitance, frequency and resistances. In addition to these measurements, the PCE-HDM 20 digital electrical tester can also perform measurements such as duty cycle, diode test and continuity test.

In addition to the electrical parameters, the digital electrical tester can also be used for temperature determination. The determination of the temperature can be done in two different ways. In the first case, the temperature can be measured by plugging in a thermocouple. In the second case, the digital electrical tester offers non-contact temperature measurement. For this purpose, an infrared optic is installed on the digital multimeter, which thus enables the temperature determination from a distance. The thermal image is then clearly shown on the display. For a closer look, there are five different colour palettes available, which can be chosen at will. To measure the temperature using the IR sensor, a lamp helps to make darkened areas brighter. In addition, the digital electrical tester has a laser that helps to locate the target area.

- Automatic shutdown
- 2.8" LC Display
- Built-in thermal imaging camera
- Heat measurement via IR or thermocouple
- Resistance measurement and continuity test
- Diode test and capacitance measurement
Temperature measurement with thermal imaging camera
   
Sampling rate 3 times per second
Field of view (FOV) 21° x 21°C / 0.5 m / 1 ft 7.6"
Spatial resolution (IFOV) 4.53 mrad
Resolution infrared camera 80 x 80 Pixel
Thermal sensitivity / NETD <0.1°C (0.18°F) at 30°C (86°F) / 100 mK
Frame rate 50 Hz
Focal length 7.5 mm
   
Sensor type uncooled microbolometer
Spectral range 8 ... 14 µm
Measuring range object temperature -20 ... 260°C / -4 ... 500°F
Measurement accuracy ± 3°C / 5.4°F or 3% of the measured value, at 10 ... 35°C /  50 ... 95°F ambient temperature and > 0°C / 32°F object temperature
   
General Technical Data  
Display Colour TFT, 6000 points with status display
Conversion TRMS
Reference standards IEC/EN61010-1, IEC/EN61326-1
Isolation Double
Pollution degree 2
Overload category CAT IV 600 V, CAT III 1000 V
Battery type 1 x 7.4V Li-Ion battery, 2300-mAh
Power supply charger 100 / 240V AC, 50/60 Hz, 10V DC, 1 A
Battery level indicator Yes
Automatic shutdown
After 15, 30 or 60 minutes of inactivity (deactivatable)
Fuses F10A/1000V, 10 x 38 mm (Input 10 A)
F800mA/1000V, 6 x 32 mm (Input mA, µA)
Test temperature 18 ... 28°C / 64 ... 82°F
Operating conditions 5 ... 40°C / 41 ... 104°F, <80% r.H.
Storage conditions -20 ... 60°C / -4 ... 140°F, <80% r.H.
Maximum operating height 2000 m / 2187 yd
Dimensions 175 x 85 x 55 mm / 6.9 x 3.3 x 2.1 in
Weight 540 g / 1 lb 3oz
   
Technical Data DC Voltage    
Measuring range Resolution Measurement accuracy Input resistance Overload protection
600 mV 0.1 mV ± (0.2% of measurement value + 5 Dgt) >10 MΩ 1000V DC / ACrms
6V 0.001V ± (0.2% of measurement value + 5 Dgt) >10 MΩ 1000V DC / ACrms
60V 0.01V ± (0.2% of measurement value + 5 Dgt) >10 MΩ 1000V DC / ACrms
600V 0.1V ± (0.2% of measurement value + 5 Dgt) >10 MΩ 1000V DC / ACrms
1000V 1V ± (0.2% of measurement value + 5 Dgt) >10 MΩ 1000V DC / ACrms
         
Technical Data AC Voltage (TRMS)    
Measuring range Resolution Measurement accuracy
(50 ... 60 Hz)
Measurement accuracy
(61 Hz ... 1 kHz)
Overload protection
6V 0.001V ± (0.8% of measurement value +5 Dgt)±

(2.4% of measurement value +5 Dgt) 1000V DC / ACrms
60V 0.01V ± (0.8% of measurement value +5 Dgt) ± (2.4% of measurement value +5 Dgt) 1000V DC / ACrms
600V 0.1V ± (0.8% of measurement value +5 Dgt) ± (2.4% of measurement value +5 Dgt) 1000V DC / ACrms
1000V 1V ± (0.8% of measurement value +5 Dgt) ± (2.4% of measurement value +5 Dgt) 1000V DC / ACrms
         
Technical Data DC and AC voltage (TRMS)  
Measuring range Resolution Measurement accuracy Input resistance Overload protection
6V 0.001V ± (2.4% of measurement value +20 Dgt) >10 MΩ 1000V DC / ACrms
60V 0.01V ± (2.4% of measurement value +20 Dgt) >10 MΩ 1000V DC / ACrms
600V 0.1V ± (2.4% of measurement value +20 Dgt) >10 MΩ 1000V DC / ACrms
1000V 1V ± (2.4% of measurement value +20 Dgt) >10 MΩ 1000V DC / ACrms
         
Technical Data Direct Current    
Measuring range Resolution Measurement accuracy Overload protection  
600 µA 0.1µA ± (0.9% of measurement value +5 Dgt) Protection 800-mA / 1000 V  
6000 µA 1 µA ± (0.9% of measurement value +5 Dgt) Protection 800-mA / 1000V  
60-mA 0.01-mA ± (0.9% of measurement value +5 Dgt) Protection 800-mA / 1000V  
600-mA 0.1-mA ± (0.9% of measurement value +8 Dgt) Protection 800-mA / 1000V  
10 A 0.01 A ± (1.5% of measurement value +5 Dgt) Protection 10 A / 1000V  
         
Technical Data Alternating Current (TRMS)    
Measuring range Resolution Measurement accuracy Overload protection  
600 µA 0.1 µA ± (1.2% of measurement value +5 Dgt) Protection 800-mA / 1000V  
6000 µA 1 µA ± (1.2% of measurement value +5 Dgt) Protection 800-mA / 1000V  
60-mA 0.01-mA ± (1.2% of measurement value +5 Dgt) Protection 800-mA / 1000V  
600-mA 0.1-mA ± (1.2% of measurement value +5 Dgt) Protection 800-mA / 1000V  
10 A 0.01 A ± (1.5% of measurement value +5 Dgt) Protection 10 A / 1000V  
         
Technical Data Coil Current    
Measuring range Resolution Measurement accuracy
(50 ... 60 Hz)
Measurement accuracy (61 Hz ... 1 kHz) Overload protection
30 A 0.01 A ± (0.8% of measurement value +5 Dgt) ± (2.4% of measurement value +5 Dgt) 1000V DC / ACrms
300 A 0.1 A ± (0.8% of measurement value +5 Dgt) ± (2.4% of measurement value +5 Dgt) 1000V DC / ACrms
3000 A 1 A ± (0.8% of measurement value +5 Dgt) ± (2.4% of measurement value +5 Dgt) 1000V DC / ACrms
         
Technical Data Diode Test    
Test current <1.5-mA      
Maximum voltage at the open circuit 3.3V DC      
         
Resistance and continuity test    
Measuring range Resolution Measurement accuracy Acoustic warning sound Overload protection
600 Ω 0.1Ω ± (0.5% of measurement value +10 Dgt) >50 Ω 1000V DC / ACrms
6 Ω 0.001 kΩ ± (0.5% of measurement value +5 Dgt) >50 Ω 1000V DC / ACrms
60 kΩ 0.01 kΩ ± (0.5% of measurement value +5 Dgt) >50 Ω 1000V DC / ACrms
600 kΩ 0.1 kΩ ± (0.5% of measurement value +5 Dgt) >50 Ω 1000V DC / ACrms
6 MΩ 0.001 MΩ ± (0.5% of measurement value +5 Dgt) >50 Ω 1000V DC / ACrms
60 MΩ 0.01 MΩ ± (2.5% of measurement value +10 Dgt) >50 Ω 1000V DC / ACrms
         
Technical Data Frequency    
Measuring range Resolution
Measurement accuracy Overload protection  
40 Hz ... 10 kHz 0.01 Hz ... 0.001 kHz ± (0.5% of measurement value) 1000V DC / ACrms  
60 Hz 0.01 Hz ± (0.09% of measurement value +5 Dgt) 1000V DC / ACrms  
600 Hz 0.1 Hz ± (0.09% of measurement value +5 Dgt) 1000V DC / ACrms  
6 kHz 0.001kHz ± (0.09% of measurement value +5 Dgt) 1000V DC / ACrms  
60 kHz 0.01kHz ± (0.09% of measurement value +5 Dgt) 1000V DC / ACrms  
600 kHz 0.1 kHz ± (0.09% of measurement value +5 Dgt) 1000V DC / ACrms  
6 MHz 0.001 MHz ± (0.09% of measurement value +5 Dgt) 1000V DC / ACrms  
10 MHz 0.01 MHz ± (0.09% of measurement value +5 Dgt) 1000V DC / ACrms  
         
Technical Data Duty Cycle    
Measuring range Resolution Measurement accuracy    
5 ... 95% 0.1% ± (1.2% of measurement value +2 Dgt)    
         
Technical Data Capacitance    
Measuring range Resolution Measurement accuracy Overload protection  
60 nF 0.01 nF ± (1.5% of measurement value +20 Dgt) 1000V DC / ACrms  
600 nF 0.1 nF ± (1.2% of measurement value +8 Dgt) 1000V DC / ACrms  
6 µF 0.001 µF ± (1.5% of measurement value +8 Dgt) 1000V DC / ACrms  
60 µF 0.01 µF ± (1.2% of measurement value +8 Dgt) 1000V DC / ACrms  
600 µF 0.1 µF ± (1.5% of measurement value +8 Dgt) 1000V DC / ACrms  
6000 µF 1 µF ± (2.5% of measurement value +20 Dgt) 1000V DC / ACrms  
         
Technical Data Temperature (Thermoelement Type K)  
Measuring range
Resolution
Measurement accuracy Overload protection  
-40 ... 600°C / -40 ... 1112°F 0.1°C / 0.18°F ± (1.5% of measurement value 3°C / 5.4°F) 1000V DC / ACrms  
600 ... 1000°C / 1112°F ... 1832°F 1°C / 1.8°F ± (1.5% of measurement value 3°C / 5.4°F) 1000V DC / ACrms  
         

1 x Multimeter PCE-HDM 20
2 x Measurement line
1 x Type K Type K thermocouple probe
2 x Li-ion battery
1 x Charger
1 x Power plug
3 x Attachment for power plug
1 x Micro-SD Card (8 GB)
1 x Magnet
1 x Fabric loop
1 x Temperature adapter
1 x User manual