2 year Warranty
The PCE-VM 40C Vibration data Logger with SMS alert functionality was designed for vibration and shock metering on buildings, bridges, towers, and other artificial structures. The Vibration data Logger measures vibrations in accordance to DIN 4150-3, BS 7385 and SN 640312A standards. With its internal memory for up to 100,000 readings, the PCE-VM 40C Data Logger can determine the effects of construction sites, traffic, or industrial processing on buildings over a long period of time. Features a micro SD card, GSM modem (optional), warning and alarm leds, relay output, SMS alerts, and an internal battery. These vibration logging test instruments are manufacturer calibrated. An ISO calibration certificate is an option.
- Triaxial acceleration meter
- In accordance with BS 7385 standard
- Quad band GSM (optional)
- SMS alarm notifications
- Memory size of 100,000 values (SD card)
- Integrated NiMH battery
- FFT analysis, XYZ and vector sum display
The 4-channel PCE-VM 5000 vibration data logger performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration data logger is able to record vibrations at different points of the component to be tested.
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity and displacement
- Connection of up to 4 sensors simultaneously
- Data storage on SD card
- Including 2 additional sensors for vibration
The 4-channel PCE-VM 5000 Data Logging Instrument performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested. These Data Logging Instrument are manufacturer calibrated. An ISO calibration certificate is an option.
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity and displacement
- Connection of up to 4 sensors simultaneously, 2 included
- Data storage on SD card
The 4-channel PCE-VM 5000 Vibration Data Logger performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration data logger is able to record vibrations at different points of the component to be tested.
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity and displacement
- Connection of up to 4 sensors simultaneously
- Data storage on SD card
- Including 2 additional sensors for vibration
- Including ISO Calibration Certificate
The 4-channel PCE-VM 5000-ICA Vibration Data Logger performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration measuring device is able to record vibrations at different points of the component to be tested.
- 4 channels / inputs
- Frequency range: 10 Hz ... 1 kHz
- Measurement of acceleration, velocity, displacement
- Connection of up to 4 sensors simultaneously, 2 included
- Data storage on SD card
- Sampling rate: minimum 1 sec.
- Incl. ISO calibration certificate
The Class 1 IoT data logger can be used, e.g, for sound measurement of street noise, aircraft and train noise, event noise, noise coming from construction sites, ports, factories involving heavy machinery, airport/bus stations, stadiums, horse/motor racing tracks etc. The weather conditions do not matter, and hail, snow, rain and similar are no problem for this system for outdoor noise monitoring. The IoT data logger is equipped with a GPS receiver which allows the user to assign the measured values to an exact position.
- Accuracy class 1
- GPS function
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- Incl. Outdoor Alarm Noise Meter Kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
The data logger with USB interface PCE-428-EKIT, from the field of environmental measurement technology, is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The data logger with USB interface is a class 2 device and is equipped with an octave band frequency filter. Optionally, the data logger with USB interface PCE-428-EKIT can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a SPL meter over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time
weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
The PCE-VM 31-HAWB Human Vibration Analyzer is designed for measuring human vibration at the workplace. The Vibration Analyzer can calculate hand-arm vibration measurements according to ISO 5349 and whole-body vibration measurements according to ISO 2631. Each sensor consists of a triaxial Vibration Analyzer that captures acceleration, velocity, and displacement measurements.
- Measuring of human vibration at the workplace
- Velocity, acceleration, displacement
- 3 channel FFT
- TEDS support
The PCE-830-2 Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logger also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6802 amp clamp (1000 A)
- Electrical conductor pick-up: 55 mm / 2.1 in diameter
- Range selection: manual (10 A, 100 A, 1000 A)
- Clamp dimensions: 244 mm x 97 mm x 46 mm / 9.6 in x 3.7 in x 1.8 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
The class 2 outdoor sound level data logger PCE-428-EKIT, from the field of environmental measurement technology, is an optimal sound level data logger for measurements at workplaces, construction sites, in traffic, airports, etc. The outdoor sound level data logger is equipped with an octave band frequency filter. Optionally, the outdoor sound level data logger PCE-428-EKIT can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a sound level meter over a long period of time, even in the rain.
- Accuracy class 2
- A, B, C & Z frequency rating
- Fast, Slow, Pulse and Peak time
weighting
- Statistics function
- 1/1 octave band included
- 1/3 octave band optional
- incl. outdoor noise level meter kit PCE-4xx-EKIT
- Outdoor measurement of sound and noise
The easy-to-use PCE-PA 8300 Data Logger is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:
- Voltage measurement range of 10 V ... 600 V AC
- Current measurement range of (Set 2) 30 A ... 3000 A AC
- Performance measurement range of 0 kW ... 9.999 MW (VA/VAR)
- Simultaneous display of harmonics and waveform
- Graphic Phasor diagram
- Captures transients including dip, swell, and outage
The PCE-830 Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logger also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-6801 amp clamp (100 A)
- Electrical conductor pick-up: 30 mm / 1.1 in diameter
- Range selection: manual (1 A, 10 A, 100 A)
- Clamp dimensions: 210 mm x 62 mm x 36 mm / 8.2 in x 2.4 in x 1.4 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values (single phase)
The PCE-VM 31-HAWB Human Vibration Recorder is designed for measuring human vibration at the workplace. The Vibration Recorder can calculate hand-arm vibration measurements according to ISO 5349 and whole-body vibration measurements according to ISO 2631. Each sensor consists of a triaxial Vibration Recorder that captures acceleration, velocity, and displacement measurements.
- Measuring of human vibration at the workplace
- Velocity, acceleration, displacement
- 3 channel FFT
- TEDS support
The PCE-830-3 Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logger also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
- PCE-830 + PCE-3007 flexible amp clamp (3000 A)
- Electrical conductor pick-up: 170 mm / 6.69 in diameter
- Length of electrical conductor: 610 mm / 24.0 in
- Dimensions: 257 mm x 155 mm x 57 mm / 10.1 in x 6.1 in x 2.2 in
- Sampling rate: 2 sec.
- Memory size: 512 kB (max. 52,000 values - single phase)