Current Clamp

Order no.: CA-Y3N

The Y-Series Current Clamp Adapter is designed to be used with multimeters or oscilloscopes and can measure up to 600 A, with a maximum enclosure diameter of 30 mm (1.2 in). his universally applicable Current Clamp Adapter does not need its own power supply, just connect the instrument with the test leads to the meter, removing the need to worry about the battery charge. The Current Clamp Adapter comes manufacturer calibrated.
- Measuring range: 4 A ... 600 A AC
- Accuracy: 3%
- Transformer ratio (E:A): 100 : 1

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C113

The Current Clamp from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Current Clamp can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Current Clamp via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 10 mA ... 1000 A
- Transformer Ratio: 1000 / 1
- Connection: 4 mm / 0.2 in plug

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D33N

The CA-D33N D Series Current Clamp for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows for accurate AC current measurement even at currents up to 3000 A. Due to the rectangular shape, the D Series is particularly suitable for busbars and cables with a large cross section. The Current Clamp adapter comes manufacturer calibrated with ISO certification as an option.
- Measuring range: 1 A to 3000 A
- Transformer Ratio: 1 A / 1 mA
- Connection: 4 mm / 1.6 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-Y7N

The Y-Series Current Clamp Adapter is designed to be used with multimeters or oscilloscopes and can measure up to 600 A, with a maximum enclosure diameter of 30 mm (1.2 in). his universally applicable Current Clamp Adapter does not need its own power supply, just connect the instrument with the test leads to the meter, removing the need to worry about the battery charge. The Current Clamp Adapter comes manufacturer calibrated.
- Measuring range: 1 A ... 500 A AC
- Accuracy: ≤2%
- Transformer ratio (E:A): 1 A : 1 mV AC

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D30N

The CA-D30N D Series Current Clamp for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Current Clamp is particularly suitable for busbars and cables with a large cross section.
- Measuring range: 1 A to 3000 A
- Transformer Ratio: 3 A / 1 mA
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D30CN

The CA-D30CN D Series Current Clamp for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Current Clamp is particularly suitable for busbars and cables with a large cross section. The Current Clamp adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 3000 A
- Transformer Ratio: 3 A / 1 mA
- Connection: cable with plug

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D36N

The CA-D36N D Series Current Clamp for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Current Clamp is particularly suitable for busbars and cables with a large cross section. The Current Clamp adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 3000 A
- Transformer Ratio: 1 A / 1 mA
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C148

The Multi-caliber Current Clamp from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Multi-caliber Current Clamp can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Multi-caliber Current Clamp via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 1 A ... 250 A, 1 A ... 500 A, 1 A ... 1000 A
- Transformer Ratio: 250 / 5, 500 / 5, 1000 / 5
- Connection: 4 mm / 0.2 in sockets

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-E1N

The CA-E Series Current Clamp for multimeters and oscilloscopes is a small current transformer with a clamp diameter of 8 mm (0.3 in) with a measuring range of 5 mA to a maximum of 150 A and a frequency range of up to 100 kHz.
- Measuring range: 0.05 A ... 150 A AC / DC
- Conversion ratio: 1 A / 1 mV
- 4 mm / 0.2 in banana plug

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-E6N

The CA-E Series Current Clamp for multimeters and oscilloscopes is a small current transformer with a clamp diameter of 8 mm (0.3 in) with a measuring range of 5 mA to a maximum of 150 A and a frequency range of up to 100 kHz.
- Measuring range: 5 mA ... 80 A AC / DC
- Conversion ratio: 1 A / 10 mV
- 4 mm / 0.2 in plug

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D31N

The CA-D31N D Series Current Clamp for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Current Clamp is particularly suitable for busbars and cables with a large cross section. The Current Clamp adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 500 A, 1 A to 1000 A, 1 A to 1500 A
- Transformer Ratio: 0.5 A / 1 mA, 1 A / 1 mA, 1.5 A / 1 mA
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D37N

The CA-D37N D Series Current Clamp for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Current Clamp is particularly suitable for busbars and cables with a large cross section. The Current Clamp adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 30 A, 1 A to 300 A, 1 A to 3000 A
- Transformer Ratio: 1 A / 1 V, 100 A / 1 V, 1000 A / 1 V
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D32N

The CA-D32N D Series Current Clamp for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Current Clamp is particularly suitable for busbars and cables with a large cross section. The Current Clamp adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 1000 A, 1 A to 2000 A, 1 A to 3000 A
- Transformer Ratio: 1 A / 1 mA, 2 A / 1 mA, 3 A / 1 mA
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D34N

The CA-D34N D Series Current Clamp for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Current Clamp is particularly suitable for busbars and cables with a large cross section. The Current Clamp adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 500 A, 1 A to 1000 A, 1 A to 1500 A
- Transformer Ratio: 0.5 A / 1 mA, 1 A / 1 mA, 1.5 A / 1 mA
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-K1

Current Clamp for process streams up to max. 4.5 A, 3.9 mm diameter pliers, for multimeter.


- Range: 1m A 4.5 A peak
- Measurement: AC A, DC A 

 

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-K2

Current Clamp for process streams up to max. 4.5 A, 3.9 mm diameter pliers, for multimeter.


- Range: 0.1 mA ... 450 mA peak
- Measurement: AC A, DC A

 

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D35N

The CA-D35N D Series Current Clamp for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Current Clamp is particularly suitable for busbars and cables with a large cross section. The Current Clamp adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 1000 A, 1 A to 2000 A, 1 A to 3000 A
- Transformer Ratio: 1 A / 1 mA, 2 A / 1 mA, 3 A / 1 mA
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C173

The 4-caliber Current Clamp from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The 4-caliber Current Clamp can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the 4-caliber Current Clamp via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 1 mA ... 1 A, 10 mA ... 10 A, 100 mA ... 100 A, 1 A ... 1000 A
- Transformer Ratio: 1 A / 1 V, 10 A / 1 V, 100 A / 1 V, 1000 A / 1 V
- Connection: 4 mm / 0.2 in male plugs
- Output: AC voltage

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C160

The Current Clamp from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Current Clamp can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Current Clamp via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 100 mA ... 10 A, 100 mA ... 100 A, 1 A ... 1000 A
- Input / Output: 100 mV / 1 A, 10 mV / 1 A, 1 mV / 1 A
- Connection: 4 mm / 0.2 in BNC connector for oscilloscopes
- Output: AC voltage

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D38N

The CA-D38N D Series Current Clamp for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Current Clamp is particularly suitable for busbars and cables with a large cross section. The Current Clamp adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 30 A, 1 A to 300 A, 1 A to 3000 A
- Transformer Ratio: 1 A / 1 V, 100 A / 1 V, 1000 A / 1 V
- Connection: BNC

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer