Description

The condition monitoring sound level meter is a class II (type 2) sound level, sound pressure level (SPL), decibel (dB) or noise meter with audible or visual alarm output capability. The condition monitoring sound level meter is used for long-term, continuous monitoring of occupational noise exposure limits in industrial environments such as foundries, factories and manufacturing production floors. The measuring device consists of a wall-mountable acoustic sensor on a 1.5 m / 4.92' long cable and a transmitter.

***Includes digital indicator with IP 65 rating***

Highlights

- Measuring range: 30 ... 130 dB in 3 ranges
- Resolution: 0.1 dB
- Accuracy: ± 1.5 dB
- IP 54 ingress protection rating on transmitter offers limited protection against dust ingress (no harmful
  deposit) and protection against splashed water from any direction
- IP 65 ingress protection rating on digital indicator offers total protection against dust ingress and protection
  against low-pressure water jets from any direction. Limited ingress permitted.

Specification

Measuring range 30 ... 130 dB in 3 ranges:
I. 30 ... 80 dB(A)
II. 50 ... 100 dB(A)
III. 80 ... 130 dB(A)
Resolution 0.1 dB
Accuracy ±1.5 dB
Frequency weighting
A
Power supply Via transmitter
Cable length (sensor to transmitter) 1.5 m / 4.92'
Operating conditions 0 ... 50°C / 32 ... 122°F, max. 85% RH
Microphone 1/2" precision electret
Standard IEC 61 672 (Class II)

Transmitter

Housing

ABS plastic

Power supply 90 ... 260 AC V
Calibration Adjustable by set screw
Output 4 ... 20-mA
Protection class IP 54 ingress protection rating
Operating conditions 0 ... 50°C / 32 ... 122°F, max. 85 % RH
Digital indicator
Transmitter input signal 4 – 20-mA
Indicator - 1999 ... 9999 (1 ... 3 decimals, according to the measurement value / chosen by the user)
Programming data (decimals, limit value ..)Saved in the unit
Regulation output 3 points (Com, NO, NC)
Alarm outputRelay output: 5 A / 240V AC
Power 90 ... 260 AC V / 50 ... 60 Hz
Dimensions / Switchboard according to DIN 92 (+ 0.8) mm x 45 (+ 0.5) mm
WeightApprox. 250 g / 0.56 lb
Operating conditions 0 ...50°C / 32 ... 122°F, max. 85% RH
Protection class IP 65 ingress protection rating

Delivery Scope

1 x Condition Monitoring Sound Level Meter PCE-SLT (consisting of 1 x acoustic sensor on a 1.5 m / 4.92' long cable and a transmitter)
1 x Wall-mounting bracket for sensor
1 x Digital indicator
1 x User manual