Condition Monitoring

Condition Monitoring Sound Level Meter PCE-SLT-TRM
£ 309.00
Price excl. VAT &. delivery

The class 2 (type 2) Condition Monitoring Sound Level Meter is a noise meter, sound pressure level (SPL), or decibel (dB) meter with an audible or visual alarm. Used for long-term measurement of occupational noise exposure limits, the Condition Monitoring Sound Level Meter is an effective device across the industry spectrum. 


  • Class 2
  • Measuring range: 30 … 130 dB in 3 ranges
  • Resolution: 0.1 dB
  • Accuracy: ±1.5 dB
  • Frequency weighting: A
  • Time weighting: Fast
  • Output: 4 … 20 mA
  • IP 54 ingress protection rating on transmitter

 

Condition Monitoring Thermometer PCE-313A-ICA incl. ISO Calibration Certificate
£ 407.00
Price excl. VAT &. delivery
ISO Calibration

The Condition Monitoring Thermometer measures relative humidity and temperature and can be used in the air-conditioning sector. The Condition Monitoring Thermometer can be connected to type K thermo-elements to detect, for instance, the temperature of a wall by means of a surface probe. The internal memory of this test equipment allows the Condition Monitoring Thermometer to record humidity and temperature data at an adjustable measurement interval. Thanks to its SD memory card (1 to 16 GB) the Condition Monitoring Thermometer can be used for long term data acquisition.


  • Relative humidity: 5 … 95% r.H.
  • Temperature: 0 … 50°C / 32 … 122°F
  • Type K: -50 … 1300°C / -58 … 2372°F
  • Calculated dew point: -25.3 … 48.9°C / -13.5 … 120°F
  • Wet bulb temperature: -21 … 50°C / -5.8 … 122°F
  • Memory: SD card (1 … 16 GB)
  • Incl. ISO Calibration Certificate

 

Condition Monitoring Paint Viscosity Tester PCE-RVI 8
£ 1,830.00
Price excl. VAT &. delivery

The condition monitoring paint viscosity tester has a measuring range of 27…. 5250 cp and an accuracy of +1% of the measuring range. The condition monitoring paint viscosity tester is used, for example, in quality control of production processes. In addition, the condition monitoring paint viscosity tester is particularly used in laboratories of all kinds.

  • Measuring range: 27 … 5250 cp
  • Rotation speed: 200 RPM
  • Volume measuring cup: 600 ml
  • Large touch screen for easy operation
  • Temperature measuring range: -20 … 250 °C / -4 … 482 °F

 

Condition Monitoring Sound Level Meter PCE-SLT-TRM-ICA incl ISO calibration cert
£ 387.00
Price excl. VAT &. delivery
ISO Calibration
The Condition Monitoring Sound Level Meter consists of a microphone with handle, a wall bracket with 1.5 m / 4.9 ft cable, and a sound transmitter. The main application area of this Condition Monitoring Sound Level Meter lies in continuous noise monitoring of factory sites, production lines, as well as in major events such as auto racing and festivals. 

  • Measuring range: 30 … 130 dB in three ranges
  • Resolution: 0.1 dB
  • Relay output and control output
  • Handle and wall holder
  • Analog output signal
  • Incl. ISO calibration
Condition Monitoring Class 2 Sound Level Data Logger PCE-SDL 1
£ 199.00
Price excl. VAT &. delivery

PCE-SDL 1 is a Condition Monitoring Class 2 (type 2) Data-logging Sound Level Meter, sound pressure level (SPL) meter, noise meter or decibel (dB) meter used for long-term acoustic measurements.


  • Measuring range: 30 … 130 dB
  • Accuracy: ± 1.4 dB
  • Frequency: 31.5 Hz … 8 kHz
  • Frequency weighting: A and C
  • Memory: Stores up to 129,920 data sets or 36 hours at 1-sec interval
  • Includes USB interface and Windows-compatible software for data transfer to PC

 

Condition Monitoring Sound Meter PCE-SDL 1-ICA incl. ISO-Calibration Certificate
£ 289.00
Price excl. VAT &. delivery
ISO Calibration

The PCE-SDL 1 is a class 2 (type 2) data-logging Condition Monitoring Sound Level Meter, sound pressure level (SPL) meter, noise meter or decibel (dB) meter used for long-term acoustic measurements. The Condition Monitoring Sound Level Meter is equipped with a USB interface for download the logged data to a PCE or portable.


 

  • Class 2
  • Measuring range: 30 … 130 dB
  • Accuracy: ± 1.4 dB
  • Frequency: 31.5 Hz … 8 kHz
  • Frequency weighting: A and C
  • Memory: Stores up to 129,920 data sets or 36 hours at 1-sec interval
  • Includes USB interface and PC-compatible software for data transfer
  • incl. ISO Calibration Certificate

 

Condition Monitoring Thermometer PCE-HPT 1
£ 424.00
Price excl. VAT &. delivery

The condition monitoring thermometer is a highly accurate 1-channel temperature measuring device. The condition monitoring thermometer is ideally suited to operate various PT-100 sensors and thus for condition monitoring. By using four-wire technology, the response time is particularly fast and accurate.

  • Measuring range: -100 … +400 °C / -148 … 752 °F
  • Accuracy: ± 0.05% + 0.1 °C / 0.18 °F (at 18 to 28 °C / 64.4 … 82.4 °F) device only
  • Resolution: 0.01 °C / 0.018 °F
  • PT-100 sensor

 

Condition Monitoring Inspection Camera PCE-VE 180
£ 267.00
Price excl. VAT &. delivery

The PCE-VE 180 is a rechargeable handheld condition monitoring inspection camera with video recording and image capture functionality. Equipped with built-in LED lighting on the waterproof camera tip, the condition monitoring inspection camera features a detachable remote control with integrated 3.5" LCD for easy viewing and navigation. The remote control communicates using radio transmission at 2.4 GHz.

 

  • Semi-flexible gooseneck cable
  • 1 m / 3.28 ft cable length
  • 3.9 mm / .16 in cable diameter- Includes detachable 4.5 mm / .18 in mirror, hook and magnet

 

Condition Monitoring Inspection Camera PCE-VE 390N
£ 1,246.00
Price excl. VAT &. delivery

The PCE-VE 390N is the ideal condition monitoring inspection camera for the analysis of buildings (walls, supports, eaves, gutters, attics, crawl spaces), plumbing (pipes, drains, sewers, wells) and heating, ventilation, air conditioning and refrigeration (HVACR) systems (ducts, furnaces, chimneys, boiler and condenser tubes). The IP68-rated cable of this condition monitoring inspection camera is waterproof and heavy duty, making it well suited for use in tough environments like construction sites and industrial installations.


  • Camera head diameter: 28 mm / 1.1"
  • Camera cable length: 10 m / 32 ft 9"
  • Interface: Mini-USB 1.1 and AV out
  • Memory: 8 GB SD memory card (incl.)
  • Especially suitable for chimneys, downpipes, ventilation ducts etc.