Order no.: PCE-HT 422

CO2 Analyser PCE-HT 422

£ 320.00
£ 384.00
PCE-HT 422
price ex. (VAT / delivery)
Delivery time: 10 - 14 days

Description

CO2 Analyser for temperature, relative humidity, CO2, TVOC and light intensity / 4GB memory / Power over Ethernet / MQTT / Email alarm / HTTP / FTP


The CO2 analyser is used to measure and store environmental data such as temperature, humidity, illuminance, CO2 content and TVOC concentration. The CO2 analyser also calculates the dew point, absolute humidity and the water vapor content in the air. The CO2 analyser is used for stationary monitoring of laboratories, greenhouses, medicine and food stores, museums, etc. The data measured and calculated by the CO2 analyser are stored in the internal memory and can be called up via Ethernet and sent to the user. In addition to storing the measurement data, the CO2 analyser can send alarms by email or display them on a website. The CO2 analyser can be supplied via a power supply unit or autonomously via Power over Ethernet. An internal battery is built into the CO2 analyser to buffer the memory and the settings.

In addition to the built-in Ethernet interface, the CO2 analyser also has an RS485 interface available to the user. This can be addressed via Modbus RTU. The user can communicate with the CO2 analyser via Modbus TCP / IP, HTTP, FTP via the Ethernet interface. A web and FTP server as well as a DHCP and SMTP client complete the functionality of the CO2 analyser's network interface.


Highlights

- Temperature measuring range (-20 ... +60 °C)
- Relative humidity measuring range (0 ... 95%)
- CO2, TVOC and light measurement
- Ethernet interface (PoE compatible)
- Alarm (acoustic, email, visual)
- 4 GB memory
- Adjustable sampling / storage rate
- FTP, HTTP server

Specification

Measured variableAir humidity
Measuring range 0 ... 95% r.H.
Accuracy ± 3 % of reading (10 .. 90 %)
  ± 5 % of other
Resolution
-
   
Measured variable Temperature
Measuring range -20 ... 60 °C
Accuracy
± 0.6 °C (10 ... 40 °C)
  ± 1 °C of other
Resolution
-
   
Measured variable Illuminance
Measuring range 0 ... 60000 lx
Accuracy
-
Resolution
-
   
Measured variable TVOC
Measuring range 0 ... 60000 ppb
Accuracy
-
Resolution
1 ppb (0 ... 2008 ppb)
  6 ppb (... 11110 ppb)
  32 ppb (... 60000 ppb)
   
Measured variable CO2
Measuring range 400... 60000 ppm
Accuracy
-
Resolution
1 ppm (400 ..1479ppm)
  3 ppm (... 5144 ppm)
  9 ( ...17597 ppm)
  31 ppm ( .. 60000 ppm)
   
Measured variables dew point absolute humidity
  saturated steam pressure, enthalpy
Interface
RS485 (Modbus RTU)
Ethernet Modbus TCP, HTTP, FTP, MQTT
Memory 4 GB
Power supply DC power pack 6 V / 1 A
  PoE IEEE 802.3af
Power consumption < 2 VA
Warm-up time 15 minutes
Operating conditions -20 ... 60°/ 95% r.H
Degree of protection IP20
Mounting Rear mounting hole for
  Wall mounting, sensor facing down
Dimensions
120 x 80 x 25 mm
Weight
300 g
   

Delivery Scope

1 x CO2 Analyser PCE-HT 422
1 x instruction manual

Note: The power supply unit must be selected as an option!