Clamp on Tester

Order no.: CA-D30CN

The CA-D30CN D Series Clamp on Tester for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Clamp on Tester is particularly suitable for busbars and cables with a large cross section. The Clamp on Tester adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 3000 A
- Transformer Ratio: 3 A / 1 mA
- Connection: cable with plug

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D36N

CA-D36N D Series Clamp on Tester
for oscilloscopes / for AC currents from 100 mA to 3000 A / 30 Hz - 50 kHz bandwidth / enclosure - Ø 64 mm / no power supply needed

The CA-D36N D Series Clamp on Tester for oscilloscopes, from Chauvin Arnoux, with its excellent characteristics is very suitable for the measurement of high currents. The high quality, low phase shift, and the wide frequency range of the D Series Clamp on Tester ensures accurate measurements, even with power measurements. The Clamp on Tester has a high-quality iron core with evenly distributed windings, allowing for accurate AC current measurement even at currents up to 3000 A. Due to the rectangular shape, the D Series is particularly suitable for busbars and cables with a large cross section. In total there are 10 different models of the D Series current transformers for oscilloscopes. They differ mainly in measuring range, CT ratio, and output. When measuring with the D Series the range that can be selected is between the maximum values 1500 A and 3000 A. The conversion ratio must be configured on either alternating current or voltage. And finally, the different models of the D Series differ in their output. There is a variant socket, cable with safety plug, and cable with BNC connector. Thus the D Series is suitable for both oscilloscopes and multimeters.

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C148

The Multi-caliber Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Multi-caliber Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Multi-caliber Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 1 A ... 250 A, 1 A ... 500 A, 1 A ... 1000 A
- Transformer Ratio: 250 / 5, 500 / 5, 1000 / 5
- Connection: 4 mm / 0.2 in sockets

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-E1N

The CA-E Series Clamp on Tester for multimeters and oscilloscopes is a small current transformer with a clamp diameter of 8 mm (0.3 in) with a measuring range of 5 mA to a maximum of 150 A and a frequency range of up to 100 kHz.
- Measuring range: 0.05 A ... 150 A AC / DC
- Conversion ratio: 1 A / 1 mV
- 4 mm / 0.2 in banana plug

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-E6N

The CA-E Series Clamp on Tester for multimeters and oscilloscopes is a small current transformer with a clamp diameter of 8 mm (0.3 in) with a measuring range of 5 mA to a maximum of 150 A and a frequency range of up to 100 kHz.
- Measuring range: 5 mA ... 80 A AC / DC
- Conversion ratio: 1 A / 10 mV
- 4 mm / 0.2 in plug

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D31N

The CA-D31N D Series Clamp on Tester for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Clamp on Tester is particularly suitable for busbars and cables with a large cross section. The Clamp on Tester adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 500 A, 1 A to 1000 A, 1 A to 1500 A
- Transformer Ratio: 0.5 A / 1 mA, 1 A / 1 mA, 1.5 A / 1 mA
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D37N

The CA-D37N D Series Clamp on Tester for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Clamp on Tester is particularly suitable for busbars and cables with a large cross section. The Clamp on Tester adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 30 A, 1 A to 300 A, 1 A to 3000 A
- Transformer Ratio: 1 A / 1 V, 100 A / 1 V, 1000 A / 1 V
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D32N

The CA-D32N D Series Clamp on Tester for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Clamp on Tester is particularly suitable for busbars and cables with a large cross section. The Clamp on Tester adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 1000 A, 1 A to 2000 A, 1 A to 3000 A
- Transformer Ratio: 1 A / 1 mA, 2 A / 1 mA, 3 A / 1 mA
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D34N

The CA-D34N D Series Clamp on Tester for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Clamp on Tester is particularly suitable for busbars and cables with a large cross section. The Clamp on Tester adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 500 A, 1 A to 1000 A, 1 A to 1500 A
- Transformer Ratio: 0.5 A / 1 mA, 1 A / 1 mA, 1.5 A / 1 mA
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-K1

Clamp on Tester for process streams up to max. 4.5 A, 3.9 mm diameter pliers, for multimeter.


- Range: 1 m A 4.5 A peak
- Measurement: AC A, DC A 

 

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-K2

Clamp on Tester for process streams up to max. 4.5 A, 3.9 mm diameter pliers, for multimeter.


- Range: 0.1 mA ... 450 mA peak
- Measurement: AC A, DC A

 

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D35N

The CA-D35N D Series Clamp on Tester for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Clamp on Tester is particularly suitable for busbars and cables with a large cross section. The Clamp on Tester adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 1000 A, 1 A to 2000 A, 1 A to 3000 A
- Transformer Ratio: 1 A / 1 mA, 2 A / 1 mA, 3 A / 1 mA
- Connection: 4 mm / 0.2 in socket

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C173

The 4-caliber Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The 4-caliber Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the 4-caliber Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 1 mA ... 1 A, 10 mA ... 10 A, 100 mA ... 100 A, 1 A ... 1000 A
- Transformer Ratio: 1 A / 1 V, 10 A / 1 V, 100 A / 1 V, 1000 A / 1 V
- Connection: 4 mm / 0.2 in male plugs
- Output: AC voltage

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-C160

The Clamp on Tester from the C1XX series for multimeters has a diameter of 52 mm (2.0 in), maximum 1000 A AC, and is designed for power and harmonics measurement. The Clamp on Tester can be connected via 4 mm (0.2 in) safety plugs to a multimeter. It is also possible to connect the Clamp on Tester via the 4 mm (0.2 mm) sockets or the BNC connector to a data acquisition system. The test instrument comes manufacturer calibrated. As all instruments, it can be certified to ISO as an option.
- Measuring range: 100 mA ... 10 A, 100 mA ... 100 A, 1 A ... 1000 A
- Input / Output: 100 mV / 1 A, 10 mV / 1 A, 1 mV / 1 A
- Connection: 4 mm / 0.2 in BNC connector for oscilloscopes
- Output: AC voltage

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-D38N

The CA-D38N D Series Clamp on Tester for oscilloscopes has a high-quality iron core with evenly distributed windings. This allows accurate AC current measurement, even at currents up to 3000 A. Due to the rectangular shape, the Clamp on Tester is particularly suitable for busbars and cables with a large cross section. The Clamp on Tester adapter comes manufacturer calibrated with ISO calibration as an option.
- Measuring range: 1 A to 30 A, 1 A to 300 A, 1 A to 3000 A
- Transformer Ratio: 1 A / 1 V, 100 A / 1 V, 1000 A / 1 V
- Connection: BNC

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer
Order no.: CA-B102

The CA-B102 Clamp on Tester is designed for fast location of insulation faults. The Clamp on Tester has a maximum diameter up to 112 mm (4.4 in), and can be used with multimeters. Two selectable measuring ranges are available to allow for precise measurement according to DIN VDE 010.
- Dual range: 4 A and 400 A AC
- Large jaw diameter: 112 mm / 4.4 in
- For measurement according to DIN VDE 0100

Manufacturer: Chauvin Arnoux GmbH
Test Instruments manufacturer