Order no.: PCE-CM 5

Automotive Tester PCE-CM 5

£ 26.00
£ 31.20
:
4250348719102
PCE-CM 5
price ex. (VAT / delivery)
Delivery time: 1-2 working days

Description

Automotive tester PCE-CM 5
Digital multimeter with NCV measurement / Current measurement up to 200 A AC / Frequency measurement directly at the current clamp / Ready for immediate use / Simple operation


The digital multimeter is a multimeter with a multitude of different functions. Thus, with the digital multimeter, current measurements up to 200 A AC can be carried out without contact. This current range of the digital multimeter already covers a large range of current measurements. Thanks to the contactless current measurements of the digital multimeter can be measured during operation. Thus, no measurement preparation must be made with the digital multimeter, since it is possible to measure directly on the line to be measured.

Another contactless feature of the digital multimeter is the NCV (Not Connected Voltage) measurement. In this measurement, the digital multimeter can indicate whether a voltage is applied to a line. Again, no measurement preparation must be carried out during operation with the digital multimeter. These two features of the digital multimeter reduce the risk of injury from electric shock.

Other useful functions of the ammeter are the measurement of the resistance and the continuity test. With the continuity check of the digital multimeter, it can be determined, for example, whether a relay in a switch box is completely closed. Thanks to the fast measuring frequency of the digital multimeter, possible power fluctuations can be determined. This makes the digital multimeter an indispensable tool for every electrician.


Highlights

- Inductive current measurement up to 200 A AC
- Voltage measurement with frequency meter
- "Hold" function for freezing the measured value
- Temperature measurement with thermocouple
- Small and compact design
- Smaller internal resistance with the LowZ function


Specification

Alternating current 
Measuring rangeResolutionAccuracy
200 A0.1 A± (3.0% + 3 digits)
Frequency range: 40 ... 400 Hz
Maximum input current: 200 A AC
  

 
Direct current 
Measuring rangeResolutionAccuracy
600 µA0.1 µA± (1.0% + 4 digits)
1000 µA1 µA± (1.0% + 4 digits)
Maximum input current: 1000 µA
  

 
DC 
Measuring rangeResolutionAccuracy
600 mV0.1 mV± (0.7% + 3 digits)
6V0.001 V± (0.7% + 3 digits)
60V0.01 V± (0.7% + 3 digits)
600V0.1 V± (0.7% + 3 digits)
Input impedance: 10 MΩ
maximum input voltage: 600V DC AC rms
   

 
AC 
Measuring rangeResolutionAccuracy
6V0.001V± (0.8% + 3 digits)
60V0.01V± (0.8% + 3 digits)
600V0.1V± (0.8% + 3 digits)
Input impedance: 10 MΩ
Maximum input voltage: 600V DC AC rms
Frequency range: 40 ... 400 Hz
 

 
LowZ AC / DC 
Measuring rangeResolution   Accuracy
600V0.1V± (2.0% + 3 digits)
Input impedance: 10 MΩ
Maximum input voltage: 600V DC AC rmsS
Frequency range: 40 ... 400 Hz
   

 
Resistance 
Measuring rangeResolutionAccuracy
600 Ω0.1 Ω± (0.8% + 3 digits)
6 kΩ0.001 kΩ± (0.8% + 3 digits)
60 kΩ0.01 kΩ± (0.8% + 3 digits)
600 kΩ0.1 kΩ± (0.8% + 3 digits)
6 MΩ0.001 MΩ± (1.2% + 3 digits)
60 MΩ0.1 MΩ± (1.2% + 3 digits)
Test voltage (open circuit): 0.4V
Surge protection: 250V AC / DC rms
 

 
Continuity test 
Measuring rangeResolutionaccuracy
-0.1 Ω-
Surge protection: 250 V AC / DC rms
Beep at <50 Ω
   

 
Diode test 
Measuring rangeResolutionAccuracy
-0.001V-
Surge protection: 250V AC / DC rms
Forward current: 1-mA DC
Forward voltage: 3.3V DC
   

 
Capacities 
Measuring rangeResolutionAccuracy
99.99 nF0.01 nF± (4.0% + 5 digits)
999.9 nF0.1 nF± (4.0% + 5 digits)
9.999 µF0.001 µF± (4.0% + 5 digits)
99.99 µF0.01 µF± (4.0% + 5 digits)
999.9 µF0.1 µF± (4.0% + 5 digits)
9.999 mF1 µF± (4.0% + 5 digits)
99.99 mF0.01 mF± (4.0% + 5 digits)
Surge protection: 250V AC / DC rms
   

 
Temperature (thermocouple type K) 
Measuring rangeResolutionAccuracy
-20 ... 0°C1°C± (3.0% + 2 digits)
1 ... 400°C1°C± (2.0% + 2 digits)
-4 ... 32°F1°F± (3.0% + 4 digits)
33 ... 752°F1°F± (2.0% + 4 digits)
Surge protection: 250V AC / DC rms
   

 
Frequency (with current probe) 
Measuring rangeResolutionAccuracy
99.99 Hz0.01 Hz
± (1.5% + 5 digits)
999.9 Hz0.1 Hz± (1.5% + 5 digits)
> 1 kHz0.001 kHzfor reference only
Frequency range: 10 Hz ... 1 kHz
Maximum input current: 200 A AC rms
Input range: > 60 A AC rms (if the input current increases, the frequency also increases)
   

 
Frequency (when measuring voltage) 
Measuring rangeResolutionAccuracy
99.99 Hz0.01 Hz± (1.5% + 5 digits)
999.9 Hz0.1 Hz± (1.5% + 5 digits)
9.999 Hz0.001 kHz± (1.5% + 5 digits)
> 10 kHz0.01 kHzfor reference only
Frequency range: 10 Hz ... 10 kHz
   

 
Frequency (direct measurement) 
Measuring rangeResolutionAccuracy
99.99 Hz0.01 Hz± (0.3% + 5 digits)
999.9 Hz0.1 Hz± (0.3% + 5 digits)
9.999 Hz1 Hz± (0.3% + 5 digits)
99.99 kHz0.01 kHz± (0.3% + 5 digits)
999.9 kHz0.1 kHz± (0.3% + 5 digits)
9.999 kHz1 kHz± (0.3% + 5 digits)
99.99 MHz0.01 MHz± (0.3% + 5 digits)
   
Measuring range: 10 Hz ... 60 MHz
Input impedance: 10 MΩ
Input range:> 0.2V AC rms (the input voltage increases, the frequency also increases)
Maximum input voltage: 250V AC rms
 

 
Duty cycle 
Measuring rangeResolutionAccuracy
5 ... 95%0.1%± 0.3%
   
More specifications 
Range selectionAutomatically and manually
Maximum working height2000 m / 6561.7 ft
DisplayLCD display
Largest display value5999
Overrange"OL" display
Measuring range underflow"-OL" display
Measuring rate3 measurements per second
Automatic shutdownAfter 15 minutes of inactivity
Power supply1 x 9V block battery
Operating conditions0 ... 40°C / 32 ... 104°F
Storage conditions-10 ... 50°C / 14 ... 122°F
Dimensions201 x 65 x 43 mm / 7.9 x 2.6 x 1.7 in
WeightApprox. 265 g / < 1 lb (with battery)
  


Delivery Scope

1 x Automotive tester PCE-CM 5
1 x Pair of test leads
1 x Transport bag 
1 x 9V Bock battery
1 x User manual