2 year Warranty
PCE-ATP 1 is a food safety / hygiene - ATP tester, ATP meter, lumitester or luminometer used for surface testing. This luminometer allows for quick and easy first-generation adenosine triphosphate (ATP) testing and monitoring to ensure proper cleanliness, sterilization and sanitization. PCE-ATP 1 is an ATP tester that can be used for cleanliness control and documentation in many different applications.
- Measurement range: 0 ... 999,999 relative light units (RLUs)
- Stores up to 10,000 date- and time-stamped data records to internal memory
- Enables rapid detection of bacterial or microbial residue
PCE-TDS 100H is a portable handheld clamp-on ultrasonic flow meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 57 … 720 mm / approx. 2 ... 28 in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 50 … 700, 57 … 720 mm
- Sensor temperature range: 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-M1
PCE-TDS 100H-ICA is a portable handheld clamp-on ultrasonic flow meter used for non-invasive, unobstructed and highly accurate measurements of the flow velocity of liquids in metal, plastic and rubber pipes and tubes with a diameter of 57 … 720 mm / approx. 2 ... 28 in. Software sold separately - see accessories for details.
- Measuring range: -32 ... 32 m/s, -105 ... 105 ft/s
- Resolution: 0.0001 m/s, 0.00033 ft/s
- Pipe size: DN 50 … 700, 57 … 720 mm
- Sensor temperature range: 32 ... 320°F
- Sensor installation: V, Z
- Incl. sensors TDS-M1
- Incl. ISO Calibration Certificate
The PCE-360 is a Single-Phase Power Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB
(non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
- incl. ISO Calibration Certificate
The PCE-360 is a Single-Phase Power Meter with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB
(non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
- incl. ISO Calibration Certificate
This device is a Three-Phase Power Meter / 3-Phase Power Analyzer with data logger functionality. This versatile power analyzer can take single-phase and three-phase power measurements both in real time and over an extended time period.
- Measuring range: 10 ... 999.9 V
- AC voltage AC
- Alternating current AC
- Active power
- Power factor
- Phase angle
- Frequency
- Harmonic measurement
- Data memory: 512 kB
(non-volatile memory)
- incl. 4 current clamps / tapping terminals
- Standards: IP 30 / IEC 61 010, 600 V / CAT III
- incl. ISO Calibration Certificate
The PCE-VM 31-HA Condition Monitoring Human Vibration Meter is designed for measuring human vibration at the workplace. The Condition Monitoring Vibration Meter can calculate hand-arm vibration measurements according to ISO 5349 and whole-body vibration measurements according to ISO 2631.
- Measuring of human vibration at the workplace
- Velocity, acceleration, displacement
- 3 channel FFT
- TEDS support
- Includes hand-arm sensor only - whole-body sensor sold separately (see
accessories)
The PCE-VM 31-WB Condition Monitoring Human Vibration Meter or Analyzer is designed for measuring human vibration at the workplace. The Condition Monitoring Vibration Meter can calculate hand-arm vibration measurements according to ISO 5349 and whole-body vibration measurements according to ISO 2631.
- Measuring of human vibration at the workplace
- Velocity, acceleration, displacement
- 3 channel FFT
- TEDS support
- Includes whole-body sensor only - hand-arm sensor sold separately (see
accessories)
The PCE-VM 31-HAWB Condition Monitoring Human Vibration Meter is designed for measuring human vibration at the workplace. The Condition Monitoring Vibration Meter can calculate hand-arm vibration measurements according to ISO 5349 and whole-body vibration measurements according to ISO 2631. Each sensor consists of a triaxial Vibration Meter that captures acceleration, velocity, and displacement measurements.
- Measuring of human vibration at the workplace
- Velocity, acceleration, displacement
- 3 channel FFT
- TEDS support
PCE-IR 100 is both an infrared thermometer for measuring surface temperature and a contact thermometer with probe for measuring core temperature of food. This food-grade thermometer allows for quick and easy testing of food surface temperatures without contamination using the infrared sensor, while also offering the possibility of testing food internal temperatures using the food-quality sensor probe.
- Infrared temperature range: -33 ... 220 ºC / -27 ... 428 ºF
- Probe temperature range: -55 ... 330 ºC / -67 ... 626 ºF
- Resolution: 0.2 ºC / 0.36 ºF
- IP 65 ingress protection rating allows hygienic cleaning
Without a doubt, the main advantage of this handheld cup vane air flow meter is that it doesn't need to be held exactly in the direction of the wind. Air flow meter with impellers typically have to be held exactly in the direction of the air flow to take accurate measurements. Digital cup vane air flow meter, wind direction will not influence the measurement.
- 0.9 to 35.0 m/s
- 2.5 to 126.0 km/h
- 1.4 to 68.0 knots
- 1.6 to 78.2 miles/h
Without a doubt, the main advantage of this handheld cup vane air flow meter is that it doesn't need to be held exactly in the direction of the wind. Air flow meter with impellers typically have to be held exactly in the direction of the air flow to take accurate measurements. Digital cup vane air flow meter, wind direction will not influence the measurement.
- 0.9 to 35.0 m/s
- 2.5 to 126.0 km/h
- 1.4 to 68.0 knots
- 1.6 to 78.2 miles/h
- incl. ISO Calibration Certificate