Order no.: PCE-SLS 10

Pressure / Fill Level Sensor PCE-SLS 10


£ 505.00
£ 606.00
:
4250348723079
PCE-SLS 10
price ex. (VAT / delivery)
Basic price is recalculated multiplied by the cable length.
m
Cable length is subject to a surcharge based on the length and the selected cable type.
Delivery time: 2 weeks (order-related production)

Description

Pressure / fill level sensor with ceramic membrane / Sensor and cable can be separated /
4 ... 20 mA or 0 ... 10 V output / Up to 100 mH2O measurable / ±0.35% accuracy


The level sensor is based on a ceramic measuring cell. This level sensor was developed for the measurement of levels in waste water, polluted and highly viscous media. As a special feature of this level sensor, the probe and cable part can be separated from one another. As a result, maintenance or assembly work on the sensor can be quickly replaced. The fill level sensor has a removable protective cap to protect the sensor membrane. Depending on the model, the measuring range of the level sensor extends from 0 ... 40 cmH2O to 0 ... 100 mH2O. The level sensor outputs the measured level as an analog signal. This signal can be processed by process displays, PLCs or data loggers.

Highlights

- Nominal pressures up to 100 mH2O
- Accuracy ±0.35% of the measuring range
- 39.5 mm diameter
- Cable and probe can be separated
- Suitable for sewage, fuels and water
- Ceramic sensor
- Can be used for dirty and viscous media
- Different configurations possible

Specification

Nominal pressure Filling level Overload
0.04 Bar 0 ... 0.4 mH2O 2 Bar
0.06 Bar 0 ... 0.6 mH2O 2 Bar
0.1 Bar 0 ... 1 mH2O 4 Bar
0.16 Bar 0 ... 1.6 mH2O 4 Bar
0.25 Bar 0 ... 2.5 mH2O 6 Bar
0.4 Bar 0 ... 4 mH2O 6 Bar
0.6 Bar 0 ... 6 mH2O 8 Bar
1 Bar 0 ... 10 mH2O 8 Bar
1.6 Bar 0 ... 16 mH2O 15 Bar
2.5 Bar 0 ... 25 mH2O 25 Bar
4 Bar 0 ... 40 mH2O 25 Bar
6 Bar 0 ... 60 mH2O 35 Bar
10 Bar 0 ... 100 mH2O 35 Bar
     
Accuracy (selectable) ≤ ±0.35 % of rdg. (standard)
≤ ±0.25 % of rdg. (option)
 
Output signal (selectable) 4 ... 20 mA (2-wire)
0 ... 10 V (3-wire)
 
Load Rmax = [(UB – UB min) / 0.02 A] Ω  
Influence effects auxiliary power: 0.05 % FSO / 10 V 
load: 0.05 % FSO / kΩ
 
Long-term stability ≤ ± 0.1 % FSO / year under reference conditions  
Switch-on time 700 ms  
Mean response time ≤ 200 ms  
Maximum response time 380 ms  
Measuring rate 5 Hz  
Temperature error ≤ ± 1 % of rdg. (-20 ... 80 °C)  
Short-circuit strength permanent  
Reverse polarity protection no damage, but also no function  
Lightning protection 2-wire: integrated
3-wire: none
 
Connection cable (selectable) PVC ( -5 ... 70 °C) grey Ø 7.4 mm 
PUR (-25 ... 70 °C) black Ø 7.4 mm 
FEP 4 (-25 ... 70 °C) black Ø 7.4 mm 
TPE-U (-25 ... 125 °C) blue Ø 7.4 mm
 
Housing stainless steel 1.4404  
Seals (selectable) FKM
EPDM
 
Separating membrane (selectable) ceramic Al2O3 96 %
ceramic Al2O399.9 %
 
Max. current consumption 21 mA  
Media water
sewage
fuels and oils
 
Areas of application groundwater level measurement
rain overflow basin measurement
sewage treatment plants
water treatment
level monitoring in open containers
fuel storage
tank batteries
biogas plants
 
Operating conditions -25 ... 125 °C  
Lab conditions -40 ... 40 °C  
Dimensions Ø 39.5 mm x 178.5 mm   
Weight ca. 650 g (without cable)  
     

Delivery Scope

1 x Pressure / Fill Level Sensor PCE-SLS 10 in the selected configuration
1 x User manual

Downloads