2 year Warranty
The PCE-BSH 10000 is an accurate compact digital scale or balance with piece or part counting functionality. Ideal for use in kitchens, laboratories and offices, this paper scale has a USB port for data transfer and printing.
- Weighing unit selections: g, oz, lb, dwt, ozt, ct, tl.T, tl.H, tl.J, GN, dr, MM, ToLA,
GSM, TAR, TMR
- Weighing range: 0.6 ... 10000 g / 0.0014 ... 22 lbs
- Readability or resolution: 0.2 g
- Accuracy: ± 0.6 g
- Calibratable
PCE-RCM 10 is a portable handheld particle counter used to monitor particulate matter (PM) concentrations in the air. Designed to aid in indoor air quality (IAQ) assessments, this particle counter also measures air temperature and relative humidity (RH).
- PM channels: PM 2.5, PM 10
- Particle sizes (in micrometers): 2.5 µm, 10 µm
- Temp. measuring range: -20 ... +70 °C / -4 ... +158 °F
- Humidity measuring range: 0 ... 100 % RH
- 2.4" full-color LCD with user-friendly graphics
- For indicative measurements
The photometer consists of a measurement sensor and a small wall bracket or holder with a 1.5 m / 4.9 ft cable, and a light transmitter. The application field of the photometer is the continuous measurement of daylight and light control in photo labs and production facilities, such as in the manufacturing of food and medicine.
- Measuring range: 0 ... 50000 Lux in three areas
- Resolution: 0.1 lx / lx 1
- Accuracy: ± 5% of reading
PCE-BSH 10000 is a an accurate compact digital scale or balance with piece or part counting functionality. Ideal for use in kitchens, laboratories and offices, this portable precision scale has a USB port for data transfer and printing.
- Weighing unit selections: g, oz, lb, dwt, ozt, ct, tl.T, tl.H, tl.J, GN, dr, MM, ToLA,
GSM, TAR, TMR
- Weighing range: 0.6 ... 10000 g / 0.0014 ... 22 lbs
- Readability or resolution: 0.2 g
- Accuracy: ± 0.6 g
- Calibratable
PCE-BSH 10000 is a an accurate compact digital scale or balance with piece or part counting functionality. Ideal for use in kitchens, laboratories and offices, this precision scale has a USB port for data transfer and printing.
- Weighing unit selections: g, oz, lb, dwt, ozt, ct, tl.T, tl.H, tl.J, GN, dr, MM, ToLA,
GSM, TAR, TMR
- Weighing range: 0.6 ... 10000 g / 0.0014 ... 22 lbs
- Readability or resolution: 0.2 g
- Accuracy: ± 0.6 g
- Calibratable
The radiation detector consists of a measurement sensor and a small wall bracket or holder with a 1.5 m / 4.9 ft cable, and a light transmitter. The application field of the radiation detector is the continuous measurement of daylight and light control in photo labs and production facilities, such as in the manufacturing of food and medicine.
- Measuring range: 0 ... 50000 Lux in three areas
- Resolution: 0.1 lx / lx 1
- Accuracy: ± 5% of reading
PCE-BSH 10000 is a an accurate compact digital scale or balance with piece or part counting functionality. Ideal for use in kitchens, laboratories and offices, this scale with software has a USB port for data transfer and printing.
- Weighing unit selections: g, oz, lb, dwt, ozt, ct, tl.T, tl.H, tl.J, GN, dr, MM, ToLA,
GSM, TAR, TMR
- Weighing range: 0.6 ... 10000 g / 0.0014 ... 22 lbs
- Readability or resolution: 0.2 g
- Accuracy: ± 0.6 g
- Calibratable
PCE-BSH 10000 is a an accurate compact digital scale or balance with piece or part counting functionality. Ideal for use in kitchens, laboratories and offices, this precision scale has a USB port for data transfer and printing.
- Weighing unit selections: g, oz, lb, dwt, ozt, ct, tl.T, tl.H, tl.J, GN, dr, MM, ToLA,
GSM, TAR, TMR
- Weighing range: 0.6 ... 10000 g / 0.0014 ... 22 lbs
- Readability or resolution: 0.2 g
- Accuracy: ± 0.6 g
- Calibratable
PCE-RCM 10 is a portable handheld Temperature Meter or particle counter used to monitor particulate matter (PM) concentrations in the air. Designed to aid in indoor air quality (IAQ) assessments, this particle counter also measures air temperature and relative humidity (RH).
- PM channels: PM 2.5, PM 10
- Particle sizes (in micrometers): 2.5 µm, 10 µm
- Temp. measuring range: -20 ... +70 °C / -4 ... +158 °F
- Humidity measuring range: 0 ... 100 % RH
- 2.4" full-color LCD with user-friendly graphics
- For indicative measurements
PCE-RCM 10 is a portable handheld Thermometer or particle counter used to monitor particulate matter (PM) concentrations in the air. Designed to aid in indoor air quality (IAQ) assessments, this particle counter also measures air temperature and relative humidity (RH).
- PM channels: PM 2.5, PM 10
- Particle sizes (in micrometers): 2.5 µm, 10 µm
- Temp. measuring range: -20 ... +70 °C / -4 ... +158 °F
- Humidity measuring range: 0 ... 100 % RH
- 2.4" full-color LCD with user-friendly graphics
- For indicative measurements
The weather station is compatible with and can be mounted on to a wide variety of available measuring equipment. The sensor will detect even the minutest movements of air and the results are then output in analogue form.
- Output signal: 4 … 20-mA
- Operating voltage: 12 … 36V DC
- Measurement reading range: 0.5 m/s … 50 m/s (1.1 ... 111.8 mph)
The Wind Measurer is compatible with and can be mounted on to a wide variety of available measuring equipment. The sensor will detect even the minutest movements of air and the results are then output in analogue form.
- Output signal: 4 … 20-mA
- Operating voltage: 12 … 36V DC
- Measurement reading range: 0.5 m/s … 50 m/s (1.1 ... 111.8 mph)
The wind speed sensor is compatible with and can be mounted on to a wide variety of available measuring equipment. The sensor will detect even the minutest movements of air and the results are then output in analogue form.
- Output signal: 4 … 20-mA
- Operating voltage: 12 … 36V DC
- Measurement reading range: 0.5 m/s … 50 m/s (1.1 ... 111.8 mph)
The Wind Speed Meter is compatible with and can be mounted on to a wide variety of available measuring equipment. The sensor will detect even the minutest movements of air and the results are then output in analogue form.
- Output signal: 4 … 20-mA
- Operating voltage: 12 … 36V DC
- Measurement reading range: 0.5 m/s … 50 m/s (1.1 ... 111.8 mph)
Without a doubt, the main advantage of this handheld cup vane air flow meter is that it doesn't need to be held exactly in the direction of the wind. Air flow meter with impellers typically have to be held exactly in the direction of the air flow to take accurate measurements. Digital cup vane air flow meter, wind direction will not influence the measurement.
- 0.9 to 35.0 m/s
- 2.5 to 126.0 km/h
- 1.4 to 68.0 knots
- 1.6 to 78.2 miles/h
Without a doubt, the main advantage of this handheld cup vane air velocity meter is that it doesn't need to be held exactly in the direction of the wind. Air velocity meter with impellers typically have to be held exactly in the direction of the air flow to take accurate measurements. Digital cup vane air velocity meter, wind direction will not influence the measurement.
- 0.9 to 35.0 m/s
- 2.5 to 126.0 km/h
- 1.4 to 68.0 knots
- 1.6 to 78.2 miles/h