2 year Warranty
The HVAC meter PCE-PDA 100L is a reliable differential pressure gauge for pressure measurement of gases in the range of -100 to +200 kPa. The HVAC meter PCE-PDA 100L has many different pressure measuring functions.
- Measuring range: -100 ... 200 kPa / -14.5 ... 29 psi / -1 ... 2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
The HVAC meter PCE-PDA 10L is a reliable differential pressure gauge for pressure measurement of gases in the range of ±20 kPa. The HVAC meter PCE-PDA 10L has many different pressure measuring functions.
- Measuring range: ± 20 kPa / ± 2.9 psi / ± 0.2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
- Pitot tube not included in delivery / optionally selectable
The HVACR tester is used for fast surface temperature measurement. The two laser points of the HVACR tester mark the exact measuring point and thus offer excellent assistance with the temperature measurement.
- Temperature measurement up to 1600°C / 2912°F
- Cross laser thermometer
- K-Type or infrared measurement
- Optical resolution: 60:1
- Adjustable emissivity
- Can be calibrated
- Suitable for long-term measurements
HVAC meter is an industrial inspection camera, endoscope or borescope for the non-destructive evaluation (NDE) of engines, machines and more. This HVA meter provides excellent image quality at an affordable price. An ideal tool for diagnosing issues in hard-to-reach places, the waterproof camera head features 6 LED lights with adjustable intensity for optimal illumination. In addition, digital image magnification or zoom of up to 4 times is available.
- 3.7 mm / 0.14 in diameter
- 3 m / 9.8 ft cable length
- 1600 x 1200 pixels JPEG image / 640 x 480 pixels AVI video
The IR HVAC Meter was designed for taking non-contact temperature measurements. To get accurate readings, the emissivity of the thermometer can be adjusted, depending on the operation purpose. Besides taking infrared images, the thermometer can also take normal pictures, as well as a mixture of both, due to the built-in digital camera.
- Measurement range: -20 ... +600°C / -4 ... 1112°F
- Accuracy: ± 2%, ± 2°C / 3.6°F
- Frequency image recording: 9 Hz
- Camera: 32 x 31 Pixel
The PCE-VA 20-SET is a multi-functional HVAC meter including flow hoods for assessing and balancing heating, ventilation and air conditioning or cooling (HVAC) installations. This multi-faceted anemometer-thermometer-hygrometer incorporates a 10 cm / 3.9" diam. fan impeller, easy-to-view backlit LCD, and useful functions, e.g. display hold, average val, maximum val, minimum val, auto power-off, low battery indication, and imperial/metric option.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew
point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±(3% of
measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1°C / 0.18°F
- Includes 2 x capture hoods (1 x round 210 mm / 8.3 in Ø, 1 x square 346 x 346
mm / 13.6 x 13.6 in)
- Incl. ISO Calibration Certificate
HVACR tester for visual inspection in small and narrow holes and cavities. With a diameter of 4 mm and a length of 175 or 432 mm / 6.9 or 17 in this HVACR tester is very versatile. The integrated LED lamp allows for a very good illumination of cavities to be inspected.
- Diameter only 4 mm / 0.16 in
- Useful length 175 or 432 mm / 6.9 or 17 in
- LED lighting
- Battery operation
PCE-330 is an HVAC meter or hygro-thermometer with a quick-response sensor for determining ambient temperature, relative humidity and dew point temperature. Equipped with an easy-to-read dual display, this data-logging indoor air quality (IAQ) meter features a large internal memory with storage for up to 16,000 recorded values.
- Temperature range: -20 ... 60°C / -4 ... 140°F
- Relative humidity range: 0 ... 100% RH
- Resolution: 0.1° / 0.18°F
- Accuracy: ± 0.8°C / ± 1.5°F, ± 2.0 ... 4.0% RH
- Internal memory: up to 16,000 date- and time-stamped readings
- Incl. ISO calibration certificate
PCE-WB 20SD is a data-logging HVAC meter used to measure indoor / outdoor wet bulb globe temperature (WBGT), black globe temperature (TG), wet bulb temperature (WB), dew point temperature, air temperature (TA) and relative humidity. Thus, this multipurpose data-recording device is an ideal tool for evaluating heat stress risks in different work environments.
- Programmable WBGT alarm setting with audible and visual alerts
- Manual (push-button) or automatic (adjustable 1 ... 3600 sec) sampling
- SD card memory (1 ... 16 GB) allows for quick and easy data transfer to a PC
HVAC meter is an industrial inspection camera, endoscope or borescope for the non-destructive evaluation (NDE) of engines, machines and more. This HVAC meter provides excellent image quality at an affordable price. An ideal tool for diagnosing issues in hard-to-reach places, the waterproof camera head features 6 LED lights with adjustable intensity for optimal illumination. In addition, digital image magnification or zoom of up to 4 times is available.
- 3.7 mm / 0.14 in diameter
- 1 m / 3.28 ft cable length
- 180° image rotation
With the HVAC meter it is possible to measure climate conditions such as temperature and relative humidity, as well as determining surface temperature of objects simultaneously by using the included external temperature sensor or using an infrared measurement. The HVAC meter offers features such as average value, maximum, minimum, and hold functions at a reasonable price.
- Internal probe
- Temperature: -20°C ... 60°C / -4 ... 140°F
- Relative humidity: 10 ... 90% r.H.
- Temperature of global: -22°C ... 60°C / -8 ... 140°F
- Humidity: -68°C ... 60°C / -90 ... 140°F
- Dew point temperature: depending on the sensor
- External probe
- Temperature: -50° C ... 500° C / -58 ... 932°F
- incl. ISO Calibration Certificate