2 year Warranty
The PCE-WMH-3 is an environmental tester or analyzer used to measure the moisture content of wood. This hammer-style environmental tester features preset characteristic curves for measuring moisture in 270 different wood types.
- Measuring range: 6 ... 60 % moisture content
- Accuracy: ±1 % (within 6 ... 12 % range), ±2 % (13 ... 28 %), ±2 % (29 ... 60 %)
- Resolution: 0.1 %
The environmental tester including flow hoods for assessing and balancing heating, ventilation and air conditioning or cooling (HVAC) installations. This environmental tester incorporates a 10 cm / 3.9" diam. fan impeller, easy-to-view backlit LCD, and useful functions, e.g. display hold, average val, maximum val, minimum val, auto power-off, low battery indication, and imperial/metric option.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew
point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±(3% of
measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1°C / 0.18°F
- Includes 2 x capture hoods (1 x round 210 mm / 8.3 in Ø, 1 x square 346 x 346
mm / 13.6 x 13.6 in)
- Incl. ISO Calibration Certificate
PCE-330 is an environmental tester or hygro-thermometer with a quick-response sensor for determining ambient temperature, relative humidity and dew point temperature. Equipped with an easy-to-read dual display, this data-logging indoor air quality (IAQ) meter features a large internal memory with storage for up to 16,000 recorded values.
- Temperature range: -20 ... 60°C / -4 ... 140°F
- Relative humidity range: 0 ... 100% RH
- Resolution: 0.1° / 0.18°F
- Accuracy: ± 0.8°C / ± 1.5°F, ± 2.0 ... 4.0% RH
- Internal memory: up to 16,000 date- and time-stamped readings
- Incl. ISO calibration certificate
PCE-WB 20SD is a data-logging environmental tester used to measure indoor / outdoor wet bulb globe temperature (WBGT), black globe temperature (TG), wet bulb temperature (WB), dew point temperature, air temperature (TA) and relative humidity. Thus, this multipurpose data-recording device is an ideal tool for evaluating heat stress risks in different work environments.
- Programmable WBGT alarm setting with audible and visual alerts
- Manual (push-button) or automatic (adjustable 1 ... 3600 sec) sampling
- SD card memory (1 ... 16 GB) allows for quick and easy data transfer to a PC
Environmental tester with acoustic signal, internal memory and software.
The environmental tester is a class II (type 2) sound level, sound pressure level (SPL), decibel (dB) or noise meter with audible or visual alarm output capability. The environmental tester is used for long-term, continuous monitoring of occupational noise exposure limits in industrial environments. AC powered.
- Measuring range: 30 ... 130 dB in 3 ranges
- Resolution: 0.1 dB
- Accuracy: ±1.5 dB
- Class 2 and frequency weighting: A
- Output: 4 ... 20-mA and alarm relay output of 5 A / up to 240V AC
- IP 54 ingress protection rating on transmitter
- Includes digital indicator with IP 65 rating
- Automatic range: 30 ... 130 dB
- Manual range: 30 ... 80 / 50 ... 100 / 80 ... 130 dB
- Resolution: 0.1 dB
- Accuracy: ±1.4 dB
- Memory capacity: 32700 values
- incl. software for LEQ calculation
- incl. ISO calibration certificate
Important! The LEQ value is only calculated by the software after the data transfer from the device to the PC or laptop.
With the environmental tester it is possible to measure climate conditions such as temperature and relative humidity, as well as determining surface temperature of objects simultaneously by using the included external temperature sensor or using an infrared measurement. The environmental tester offers features such as average value, maximum, minimum, and hold functions at a reasonable price.
- Internal probe
- Temperature: -20°C ... 60°C / -4 ... 140°F
- Relative humidity: 10 ... 90% r.H.
- Temperature of global: -22°C ... 60°C / -8 ... 140°F
- Humidity: -68°C ... 60°C / -90 ... 140°F
- Dew point temperature: depending on the sensor
- External probe
- Temperature: -50° C ... 500° C / -58 ... 932°F
- incl. ISO Calibration Certificate