Particle Counter PCE-PCO 2

Order no.: PCE-PCO 2
GTIN (EAN): 4250348717184
AED 5,751.00
AED 6,038.55
price ex. (customs / clearance)
:
4250348717184
PCE-PCO 2
Delivery time:1-2 working days

Description

PCE-PCO 2 Particle Counter
Portable handheld device for monitoring particulate matter (PM) concentrations in the air / 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm and 10 µm particle sizes / Measures air temperature, dew point and relative humidity

This is a portable handheld particle counter used to monitor particulate matter (PM) concentrations in the air. Designed to aid in indoor air quality (IAQ) assessments, this particle counter also measures formaldehyde air temperature, dew point and relative humidity.

The particle counter is ideal for monitoring clean rooms, exposure to exhaust, smoke and other harmful air pollutants, and levels of airborne combustible dust such as agricultural dust, carbonaceous dust, chemical dust, metal dust, plastic dust and wood dust.

A variety of materials are explosive in dust form. Some examples include: food (e.g., candy, sugar, spice, starch, flour and feed), grain, tobacco, plastics, wood, paper, pulp, rubber, pesticides, pharmaceuticals, dyes, coal and metals (e.g., aluminum, chromium, iron, magnesium and zinc). These materials are used in agriculture, chemical manufacturing, pharmaceutical production, furniture, textiles, fossil fuel power generation, recycling operations, metal working and processing (including additive manufacturing and 3D printing) and many other industries and processes.

In addition to being a combustion hazard, certain kinds of dust can be a health hazard. Exposure (such as skin contact, eye contact and inhalation) can be linked to sneezing, a stuffy or runny nose, itchy or red eyes, headaches, fatigue, fever, cough, shortness of breath, dermatitis, asthma, bronchitis, pneumonia (e.g., Legionnaires’ disease and hypersensitivity pneumonitis) and cancer.

When inhaled, PM 2.5 and PM 10 particles can settle deep into the lungs and result in damaging health effects. Since the PCE-PCO 2 particle counter monitors PM 2.5 and PM 10 particles, the device has many practical health and safety applications. Heating, ventilation and air conditioning (HVAC) technicians use PM 2.5 and PM 10 particle counters for HVAC system performance and filtration audits. In addition, industrial hygienists and workplace safety professionals rely on PM 2.5 and PM 10 particle counters when evaluating occupational health and safety risks related to hazardous and combustible dust.


Highlights

- Captures 6 particle sizes
- Measures air temperature, dew point and relative humidity
- 2.8" TFT full-color LCD screen
- Built-in camera for image and video recording
- Cumulative, differential and concentration particle counting modes
- Stores up to 5,000 data sets to memory
- Power-saving automatic shutdown feature
- PM channels: PM 2.5, PM 10, including mass concentration mode (µg/m³)
- Free software download on PCE Software web page

Specification

Particle 
Measuring channel sizes  0.3, 0.5, 1.0, 2.5, 5.0, 10
Measuring range  0,3 ... 10 µm
Counting efficiency  50 % at 0.3 µm;
100 % at particle size > 0.45 µm
Flow volume  2,83 l/min
Coincidence error  <5% at 2,000,000 particles per ft³
  
Particle 
Measuring range  0 ... 2000 µg/m³
Resolution  1 µg/m³
Measuring channel sizes  PM2,5, PM10
  
Dew point 
Measuring range  0 ... 10 °C
Resolution  0,1 °C
Accuracy  ±1°C
  
Dew point 
Measuring range  10 ... 40 °C
Resolution  0,1 °C
Accuracy  ±0.5°C
  
Dew point 
Measuring range  40 ... 50 °C
Resolution  0,1 °C
Accuracy  ±1°C
  
Relative humidity 
Measuring range  0 ... 20 % RH
Resolution  0,1 % RH
Accuracy  ±5 % RH
  
Relative humidity 
Measuring range  20 ... 40 % RH
Resolution  0,1 % RH
Accuracy  ±3.5 % RH
  
Relative humidity 
Measuring range  40 ... 60 % RH
Resolution  0,1 % RH
Accuracy  ±3 % RH
  
Relative humidity 
Measuring range  60 ... 80 % RH
Resolution  0,1 % RH
Accuracy  3.5 % RH
  
Relative humidity 
Measuring range  80 ... 100 % RH
Resolution  0,1 % RH
Accuracy  ±5 % RH
  
Temperature 
Measuring range  0 ... 10 °C
Resolution  0,1 °C
Accuracy  ±1 °C
  
Temperature 
Measuring range  10 ... 40 °C
Resolution  0,1 °C
Accuracy  ±0.5 °C
  
Temperature 
Measuring range  40 ... 50 °C
Resolution  0,1 °C
Accuracy  ±1 °C
  
General technical data 
Display type  LCD with backlight
Display size  2,8 Inch
Display resolution  320 x 240 pixels
Storage medium  Internal memory
Storage capacity  80 MB
Memory capacity (additional information)  Micro SD card 5000 data records
Interface  Mini-USB
Sensor  Laser scattered light
Operating time  4 h
Automatic power-off from...to  3 ... 60 min.
Menu language  English, French, German, Spanish
Protection class (device)  IP20
Connector type  Device-europlug
(Rechargeable) battery  1 x 7,4 V internal , Lithium polymer battery
Capacity  1200 mAh
Operating conditions  0 ... 50 °C , 10 ... 90 % RH
Storage conditions  0 ... 50 °C , 10 ... 90 % RH
Dimensions ( L x W x H )  240 x 75 x 55 mm
Weight  420 g

Delivery Scope

1 x PCE-PCO 2 air sampler
1 x zero filter
1 x rechargeable battery
1 x AC charger
1 x USB cable
1 x user manual
1 x CD-ROM (software)
1 x mini tripod
1 x hard case