The easy-to-use PCE-PA 8300 Data Logger is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:
The PCE-830 Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logger also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
The easy-to-use PCE-PA 8300 Three Phase Power Data Logger is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:
The PCE-830 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This 3-Phase Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.
PCE-PCO 1 is a handheld data logger for measuring the concentration of particles in the air. The PCE-PCO 1 data logger:
The Data Logger with microprocessor is a high precision 1-channel temperature gauge. The Data Logger with microprocessor is ideal for use with various Pt100 sensors. These temperature logging test instruments are calibrated by the manufacturer. An ISO calibration certificate is available as an option.
The redox meter PCE-PHD 1-R is a multifunction meter for checking water quality. The portable redox meter is very well suited for controlling the redox value in water.
The pH meter PCE-PHD 1-PH is for checking the water quality. The portable pH meter is very well suited for controlling the water parameter pH.
The Dissolved Oxygen Data-Logging Meter PCE-PHD 1-O2 is a true all-rounder for checking the water quality. The portable oxygen meter is used to control the water parameters pH (optional), temperature (optional), conductivity (optional), salinity (optional) and oxygen.
The pH / Conductivity / Salt / Oxygen Water Quality Data Logger PCE-PHD-1-KIT1 is a true all-rounder for checking water quality. The portable data logger is used to control the water parameters pH, redox, conductivity, salinity, oxygen and is also very suitable for temperature measurement. Storage, electrolyte, conductance and calibration solutions are included in this comprehensive kit.
The temperature data logger with microprocessor is a high precision 1-channel temperature gauge. The temperature data logger with microprocessor is ideal for use with various Pt100 sensors.
The Conductivity Data-logging Meter PCE-PHD 1-LF is for checking the water quality. The portable conductivity meter is very suitable for controlling the conductivity in the water.
The PCE-PHD 1-ICA pH / Conductivity / Salt / Oxygen Water Quality Data Logger is a portable and effective measuring device with multiple capabilities for inspecting water quality. Offering extraordinary precision at an affordable price, the data logger is used for laboratory and in situ testing of the pH value, redox, conductivity, salt content, oxygen level and temperature of water.
The PCE-PHD 1 pH / Conductivity / Salt / Oxygen Water Quality Data Logger is a portable and effective measuring device with multiple capabilities for inspecting water quality. Offering extraordinary precision at an affordable price, the data logger is used for laboratory and in situ testing of the pH value, redox, conductivity, salt content, oxygen level and temperature of water.
PCE-SDL 1 is a class 2 (type 2) data logging sound level meter, sound pressure level (SPL) meter, noise meter or decibel (dB) meter used for long-term acoustic measurements. The instrument is equipped with a USB interface for download the logged data to a PCE or portable.
This weather data logger with outside sensor is a real all-rounder. The wireless weather data logger with outside sensor is easy to assemble based on the instructions provided. You do not have to be a professional to operate the wireless weather data logger and outside sensors. The weather data of the weather data logger with outside sensor for different parameters are sent up to 100 meters by radio signal to the main station.
PCE-SDL 1 is a class 2 (type 2) data-logging sound level meter, sound pressure level (SPL) meter, noise meter or decibel (dB) meter used for long-term acoustic measurements.
PCE-PCM 1 is a three phase power data logger or power analyzer used to measure alternating current (AC), voltage (TRMS) and frequency to determine active (kW), apparent (kVA) and reactive (kVAR) power as well as active energy (kWh) consumption. Both the phase angle and the power factor (cos φ) are shown on the handheld power meter's large and easy-to-read backlit display.
Data logger with internal memory and software.
PCE-432-ICA is a class 1 sound level data logger that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level data logger is equipped with GPS functionality, allowing measured values to be assigned to a precise geographic location. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).
PCE-430 is a class 1 sound level data logger that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy class 1 sound level data logger has a large easy-to-read illuminated LCD screen that displays the sound pressure level (SPL) numerically and graphically in real time.
The class 1 sound level data logger meets all requirements for noise measurement and frequency analysis. This integrating precision pulse sound level data logger complies with all applicable standards and guidelines.
The PCE-830-2 Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logger also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
The class 2 outdoor sound level data logger PCE-428-EKIT, from the field of environmental measurement technology, is an optimal sound level data logger for measurements at workplaces, construction sites, in traffic, airports, etc. The outdoor sound level data logger is equipped with an octave band frequency filter. Optionally, the outdoor sound level data logger PCE-428-EKIT can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a sound level meter over a long period of time, even in the rain.
The Sound Level Data Logger PCE-432 is a class 1 data logging sound level meter that meets IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013, ANSI S1.4-1983 and ANSI S1.43-1997 requirements. This portable high-accuracy sound level data logger is equipped with GPS functionality, allowing measured values to be assigned to a precise geographic location. The sound level data logger calculates the equivalent continuous sound level Leq (LXeq).
The class 2 outdoor sound level data logger PCE-428-EKIT-ICA, from the field of environmental measurement technology, is an optimal sound level data logger for measurements at workplaces, construction sites, in traffic, airports, etc. The outdoor sound level data logger is equipped with an octave band frequency filter. Optionally, the outdoor sound level data logger can be upgraded with a 1/3 octave band filter. The additional kit for outdoor sound measurement makes it possible to measure outdoor noise with a sound level data logger over a long period of time, even in the rain.
The easy-to-use PCE-PA 8300 Data Logger is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:
The PCE-830-3 Data Logger is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logger also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The power logging instrument is delivered manufacturer calibrated. An ISO calibration certificate may be ordered optionally.
The easy-to-use PCE-PA 8300 Three Phase Power Data Logger is the ideal tool for performing power and harmonics analysis as well as for measuring network capacity. The PCE-PA 8300 is a 3-phase power analyzer that features:
The 4-channel PCE-VM 5000 vibration data logger performs vibration measurements on up to 4 places at the same time. The vibration velocity, acceleration, and displacement in a frequency range of 10 Hz to 1 kHz can be measured. The cables of the vibration sensors are 1.2 m / 3.9 ft long, so the vibration data logger is able to record vibrations at different points of the component to be tested.
The vibration data logger has a measuring range of 0 … 200 m/s² for acceleration. In addition to acceleration, the vibration data logger can also perform speed, displacement, frequency and an ISO 18016-3 measurement.
The PCE-830 Data Logging Instrument is used for measuring one to three phases of electrical quantities for alternating current (AC). This Data Logging Instrument also measures such parameters as voltage, current, frequency, harmonics and power as well as indicating, according to standard EN50160, harmonic values, interharmonics and asymmetrics. Interference, such as interruptions, leaks, overloads or transience (from 16µs) are detected with their corresponding values.