2 year Warranty
The PCE-HT 71N air humidity meter detects air temperature and humidity and stores readings in its internal memory. The air humidity meter has a compact format and a wide memory capacity (up to 32,000 values / 16,000 values for each parameter) and it is mainly used as a data logger in fields such as supermarket refrigeration units, refrigerated transport, warehouses, and other temperature controlled environments.
- Measurement range: 0 ... 100% RH / -35 ... 70°C / -31 ... 176°F
- Accuracy: ± 3% RH (20 ... 80%) and ± 5% / ± 1°C (1.8°F)
- Resolution: 0.5% RH / 0.1°C (0.18°F)
- Memory: Max. 32,000 measurement data (16,000 for each parameter (humidity / temperature))
- Incl. ISO calibration certificate
PCE-VA 20-SET is a multifunction relative humidity meter with capture hoods for assessing and balancing heating, ventilation and air conditioning or cooling (HVAC) systems. This combined hygrometer-anemometer-thermometer possesses a 10 cm / 3.9" diameter fan impeller and a bright backlit LCD. The functions of the meter incorporate display hold, mean value, max value, min value, battery-saving auto shutdown, low-battery display, and a choice between metric and imperial units.
- Measures air flow velocity, volume flow, relative humidity, air temperature, dew
point temperature and wet-bulb temperature
- Air flow velocity range: 0.2 ... 30 m/s (39.4 ... 5905.5 fpm)
- Accuracy: ±(1.5% of measured value + 0.3 m/s) when less than 20 m/s, ±(3% of
measured value + 0.3 m/s) when more than 20 m/s
- Resolution: 0.1°C / 0.18°F
- Includes 2 x capture hoods (1 x round 210 mm / 8.3 in Ø, 1 x square 346 x 346
mm / 13.6 x 13.6 in)
The Air Velocity Meter PCE-PDA 10L is a reliable differential pressure gauge for pressure measurement of gases in the range of ±20 kPa. The Air Velocity Meter PCE-PDA 10L has many different pressure measuring functions.
- Measuring range: ± 20 kPa / ± 2.9 psi / ± 0.2 bar
- Resolution: 10 Pa / 0.00145 psi / 0.0001 bar
- Accuracy: ± 0.5% of final value
- Min and Max value memory
- Data logger and leak test
- Temperature measurement, flow measurement
- Pitot tube not included in delivery / optionally selectable
VHF-Band Moisture Meter Crushed Stone, Gravel, Ore (conveyor). The device is resistant to corrosion (stainless steel and dielectric materials) and can operate in the conditions deviating from the norm, for example, at temperatures of 145 °C. The humidity detector probe can be mounted on the walls in the hoppers, in pipelines or on trays in conveyors. Due to pluggable design this version of the humidity detector can also be used for soil moisture control.
- Measurement range: 0 ... 100 %
- Limits of error: <0.5% below 10% moisture
- Range of working temperatures:
0 ... +90 °C (industrial version)
0 ... +115 °C (extended temperature range)
0 ... +250 °C (drying kilns)
This air humidity meter station with outside sensor is a real all-rounder. The air humidity meter station with outside sensor is easy to assemble based on the instructions provided. You do not have to be a professional to operate the air humidity meter station and outside sensors. The weather data of the air humidity meter station with outside sensor for different parameters are sent up to 100 meters by radio signal to the main station.
- Indoor temperature in Celsius or Fahrenheit
- Outside temperature in Celsius or Fahrenheit
- Indoor air humidity / outdoor air humidity
- Air pressure gauge in inHg or hPa
- Absolute or relative air pressure display selectable
- Precipitation indication in mm or inch
- Precipitation indicator for 1 hour, 24 hours, 1 week, 1 month
- Wind speed in mph, km / h, m / s, knots ...
- Wind direction indicator
- Wind chill temperature gauge
- Weather forecast, trend indicator, storm warning
- and much more...
The humidity detector is a sensor for measuring moisture of sand consisting of a central probe surrounded by four other probes. The probes and sensor housing are made of stainless steel AISI 321. Our humidity detector is ideally suited for installation in tanks with liquid materials such as fuel oil, sludge from cement production, fuels (CWF).
- Readability mass fraction of water: 0 ... 100%
- Moisture measurement range: ± 0.1 ... 100% (water mass fraction))
- Maximum permissible absolute error moisture measurement: Varies by material, lab test required
- Temperature range: +5 ... +80 °C
For industrial continuous production of wood pellets, chips, sawdust and similar materials when on-line moisture measurement for monitoring and controlling the drying and mixing process is important. Consistent quality of every batch, reduction of the consumption of materials, and shortest possible drying and mixing times are the criteria which are important in materials production. The humidity detector of PCE Instruments helps meet those criteria through highly accurate moisture measurement.
- Measuring range: 0 ... 100%
- The maximum permissible error (absolute): Lab analysis of your sample determines % error
- Temperature range: -40 ... +150 °C (-40 ... +302 °F)
- Current consumption: 200 mA
- Power supply : 24 (18 ... 36) VDC
- Questionnaire starts evaluation process
- Application: pellets, wood chips
PCE-WM1 is a multi-function absolute air humidity meter used to determine relative humidity (% RH), absolute humidity (g/m³), air temperature, dew-point temperature and surface temperature (°C). This Metric-only measuring instrument comes complete with an external sensor probe for taking the surface temperature of different materials.
- Temperature range: -20 ... 80°C
- Relative humidity range: 10 ... 95% RH
- Absolute humidity range: 0.5 ... 74.4 g/m³